China Power Test Equipment manufacturer
Zhengzhou Great Electric Co.,Ltd.
Grow with our partner n the wordwide
6
Home > Products > Meter Test Bench >

High Accuracy 0.05 Class Meter Test Bench 120A Three Phase

High Accuracy 0.05 Class Meter Test Bench 120A Three Phase

Brand Name HNMC
Model Number MCTB20C
Place of Origin China
Minimum Order Quantity 1
Price Negotiable
Payment Terms L/C, T/T, Western Union
Supply Ability 20 Sets Per Month
Delivery Time 30-45 days
Packaging Details Wooden Package
Accuracy class 0.05, 0.02
Standard Meter Accuracy 0.05%, 0.02%, 0.01%
Harmonic test 2-21times
Voltage output 1-480V
Current output 1mA-120A, 200A (optional)
Output stability 0.05% or 0.02%
Detailed Product Description

0.05 Class Three Phase Electric Meter Test Bench

 

1.1:LCD touch screen:

After power on, then initialization, into default interface, main interface

 

 

 

 

 

 

1.2: Operate meter test bench and monitor the status of test bench by operating touch screen LCD.

1.2.1 Parameter settings for energy meter under test.

Press【Param】into parameter settings interface:

 

 

 

 

 

 

 

 

 

 

0.05 Class Three Phase Electric Meter Test Bench

Technical Parameters

Accuracy class0.05, 0.1 (optional)
Output Volts
Adjustment Range3*(1-480V) (P-N)
Resolution0.01%
Output Distortion<0.5%
Output Stability0.05% or better
Output Power≥ 30VA/position (total power depends on meter positions)
Current output
Adjusting Range3* (1mA~ 120A), can be up to 200A (optional)
Adjustment Resolution0.01%
Output distortion<0.5%
Output Stability0.05% or better
Output power≥ 100VA/ positions
Phase Measurement
Adjust range0° ~ 360°
Resolution0.01°
Frequency
Output Range45-65HZ
Resolution0.01HZ
Other parameters
Power supply220V or 3×240V/415V±10%, 50/60Hz±10%
Ambient conditions50C ~ 400C / up to 90% RH

0.05 Class Three Phase Electric Meter Test Bench

ARM alarm light connection definition

ARM main control board P2 PORT, 10-Cores connect to main control box where need to open a hole.install a 5 cores metal seat.

Both ends connection correspondence:

P2port 10-cores wire 5cores metal seat

2 feet +5V ------------------ 2 feet +5V

3feet green light(UO_10) ------------3feet green light

4feet yellow light (UO_9) ------------4feet yellow light

5feet red light(UO_11) ------------5feet red light

 

External control line board:LAMP_CTRLU.PcbDoc

Large 2 cores connect white 220v, black 0V,in parallel with power supply wire of standard meter.

Wiring diagram as below

External introduction light control circuit board:LAMP_CTRLU.PcbDoc

Configurations

 

1) Three Phases PS(Power source)

2) Three phase Standard meter, class 0.05 or 0.02 or 0.01

3)Meter Rack

      Number of positions: 6, 10, 12, 20, 40, 48....optional

      Each rack with one emergency STOP switch

      Each positions consist of 1 QCD 6 pins + 1 scanning head + 1 meter clamping + 1 RS/232/485

      communication port + 1 error display + 1  RESET button + 1 Set of voltage cable

      +1 ICT (need ICT or not depends on customer)

4) PC software

5) User Manuals

6) Optional

     0.05 Class Three Phase Electric Meter Test Bench

    - Isolated Current Transformer (ICT)

      Accuracy class: 0.01% (0.5C-1-0.5L)

      Current Ratio: 1:1 (1mA-120A)

      Current output: 3*(0.001-120)A (both primary and secondary)

       Secondary Output load: Maximum 0.5V (output current1mA-120A)

   -  MSVT

   - Personnel Computer

   - Printer

 

 

Product Tags: 0.05 Class Meter Test Bench   120A Class Meter Test Bench   Three Phase Class Meter Test Bench  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Zhengzhou Great Electric Co.,Ltd.
Subject:
Message:
Characters Remaining: (80/3000)