Project name | Specification parameters |
Equipment Power Supply Specifications | Equipment power AC380V 50Hz 4kw |
Sample Power Supply Specification | AC220V 16A |
LWGYD-4 flow sensor | Flow range :0.667-4.167 L/min, pulse output |
LWGYD-15 flow sensor | Flow range :10.00-100.00 L/min, pulse output |
Big pumps | 380VAC 50Hz 2.2kw protection grade: IP55 insulation grade: F |
Mini Pumps | 380VAC 50Hz 0.55kw protection grade: IP55 insulation grade: F |
Scope of waterproof test | IPX1,IPX2,,IPX3,IPX4,,IPX4K,IPX4K,IPX5,IPX6,IPX6K, IPX7,IPX8,JIS R1/R2,JIS S1/S2 |
IPX1-IPX2 | Drop area :1000*1000 mm |
| Drop hole diameter :0.4 mm |
| Drop hole spacing :20 mm |
| Test flow :1~1.5 mm/min (IPX1),3~3.5(IPX2) |
IPX3-IPX4 | Swing radius | R400mm ,R600mm ,R800mm ,R1000mm |
| Inner diameter of pendulum tube | Φ18mm |
| Pinhole diameter of pendulum tube | Φ0.4mm, hole spacing 50 mm ,0.07±0.0035 L/Min per hole |
| Swing Rainfall | According to the test standard set on the console (water supply 0.63-10 L/Min) |
| Test time | Set on console according to test criteria (range 1-9999 seconds) |
| Swing tube test angle | 0-3500 |
| Swing tube test speed | About 4-60 degrees per second |
| Speed of swing tube turntable | According to the standard, the pre-factory system has been set to 1 RPM, or 1 rpm |
| Custom testing | Any set within the º of :0-350 Test speed :4-60 degrees per second set; unit: degrees per second Test time :0-9999 seconds; set in seconds Test flow rate :0.63-10.0 L/min set arbitrarily in L/min unit |
Sprinkle water | Number of fountains | 121,φ0.5 holes |
| Test flow | 10±0.5 L/min |
| Test time | Set by test standard (range 1-9999 seconds) in seconds |
| Test pressure | 50-150 kPa |
IPX5-IPX6 | nozzle aperture | 6.3 mm (IPX5),12.5 mm (IPX6) |
| Water spray | 12.5±0.625 L/min (IPX5),100±5 L/min (IPX6) |
| Test time | Set by test standard (range 1-9999 seconds) in seconds |
| Test pressure | Water flow regulation IPX5 about 30 kpa ,IPX6 about 100 kpa |
IPX7 | Test requirements | The lowest point of the shell with 1. height less than 850 mm shall be less than 1000 mm; above the water surface The highest point of the enclosure 2. a height greater than or equal to 850 mm shall be 150 mm; below the surface of the water |
| Test time | 30 min |
IPX4K | Swing radius | R200mm,R400mm,R600mm,R800mm |
| Inner diameter of pendulum tube | Φ22mm |
| Pinhole diameter of pendulum tube | Φ0.8mm 0.6 L/min±5 per cent per hole |
| Angle of pendulum test | 360°(±180° actual ±175) |
| Test speed of pendulum tube | s/Cycle 12 |
| Swing Rainfall | 7.2-30 L/min±5% set |
| Test time | min 10(1 position 5 min,90°5) |
| Water pressure | 400 kPa |
| Speed of turntable | 1RPM |
IPX6K | Nozzle diameter | Φ6.3mm |
| Test flow | 75L/min±5 per cent |
| Test time | 0-99999.9 s Set |
| Spray pressure | 1000 kPa |
Turnover | Speed range | Tilt 15° RPM 1-20 |
| Adjust height | mm 800-1700 |
Dimensions of Water Supply and Control System | W1310mm×D890mm×H1600mm |