High Accuracy Single Point Load Cell FNN utilizes strain gauge technology to deliver high accuracy of
maximum 0.015% non-linearity of the full scale. Load sensor FNN
offers 0-60kg / 0-100kg / 0-200kg / 0-350kg / 0-500kg five rated
measuring ranges to choose from. Weight transducer FNN is corner
trimmed for platform sizes up to 40x50cm,which makes weight sensor
FNN suitable for platform weighing applications where off-center
loading exists. Weight Transducer FNN is temperature compensated to
deliver stable measuring results within its working temperature
range. You may find beam type Load Cell Sensor FNN applicable for packaging machines, bench scales, feeding
machines, intelligent warehouse weighing management system, beehive
scales and so on.
Specifications
Capacity | 60kg / 600N / 132 lbf 100kg / 1kN / 220lb 200kg / 2kN / 440 lbf 350kg / 3.5kN / 770lb 500kg / 5kN / 1.1k lbf |
Rated output | 2.0 mV/V |
Excitation | 3-15V |
Zero balance | ±0.1mV/V |
Nonlinearity | ±0.015% R.O. |
Hysteresis | ±0.015% R.O. |
Nonrepeatability | ±0.01% R.O. |
Creep(30min) | ±0.02% R.O. |
Safe overload | 150% F.S. |
Ultimate overload | 200% F.S. |
Compensated temperature | -10...+40oC |
Operating temperature | -20...+60oC |
Temperature shift zero | ±0.02% R.O./10oC |
Temperature shift span | ±0.02% R.O./10oC |
Input resistance | 405±10 ohms |
Output resistance | 350±3 ohms |
Insulation resistance | >5000M ohms |
Ingress protection | IP65 |
Material of element | Aluminum alloy |
Cable | Ø5*1500mm 4-core shielded |
Wiring code | Red--Excitation+ Black--Excitation- Green--Signal+ White--Signal- |
A Load Sensor is a transducer that converts mechanical load into electrical
signal which is proportional to the load being applied.The measured
load or force causes deformation of the measuring element(elastic
body),the bonded strain gauge deforms accordingly which will cause
the resistance change of the wheatstone bridge,under constant power
supply, the output signal between Sig+ and Sig- will change
proportionally, thus the load/force can be measured by measuring
the output signal from the load cell which is normally within
0-30mV. Overloading is the most common cause of loadcell failure, a
loadcell is just like a spring in certain aspects, which will be
damaged if overstretched or overloaded. A machanical stop(refer to
below picture) can be used to protect the sensor from excessive
deformation. The deformation distance can be determined by loading
the sensor with rated capacity, then adjust the meachnical stop to
reach the bottom of the transducer. In most cases, the load
transducer will be used to measure load at 40-80% of the full
scale, thus the deformation distance can be adjusted using
reference load which is a bit higher than the maximum target load
to be measured instead of the rated capacity.