CB Class ATS Automatic Transfer Switch Fast Changover 200ms CE Certified
|
fast changover CB class ATS automatic transfer switch 200ms CE certified1.The dual-power automatic transfer switch (ATS) is a newly developed miniature household power transfer switch, is mainly used to test whether the main power or reserve power is normal. When the normal power supply is abnormal, the reserve power supply will start work immediately to ensure continuity, reliability and safety of the power supply. It is specially designed for household rail installation for PZ30 distribution box. 2.The ATS is suitable for emergency power supply systems of AC50 or 60Hz and rated voltage 400V. It is featured with firm structure, reliable transfer, easy installation and maintenance, and long life, is widely used in places where frequent power outage is not allowed. Both electric and operation and manual operation are available. The ATS is composed of TES and controller. 3.According to the standard GB/T14048.11 Part 6-1: Multiple function equipment - Transfer switching equipment, we can know that ATS is the most suitable low-voltage switchgear and control device.
Normal running time and installation conditions 1.Ambient air temperature Temperature should be within -5℃~40℃, and the average temperature within 24h should not exceed 35℃. 2.Altitude Altitude of the installation site should not exceed 2000m. 3.Atmospheric conditions The relative humidity of the installation site should not exceed 50% at maximum temperature 40℃, and it will be higher at minimum temperature -5℃, for instance, 90% at +20℃. Please take measures for the dew on product surface caused by temperature change. 4.Class of pollution Pollution class of ATS meets the specified level of GB/T14048.11. 5.Installation category Installation category of ATS meets the specified category in GB/T14048.11 Matterts need attention 1.Manual/automatic operation ATS with automatic operation can ensure power generation and power-off performances, but for ATS with manual operation , it cannot ensure the above performance due to the speed of power generation and power-off or operator differences. Excessive silver alloy loss may occur during manual power generation and power down. Therefore, set the selector switch at the manual position under normal condition, and pull it to the manual position when all power is turned off to check and maintain the operating system and contacts. After the manual operation is completed pull the selector back to the automatic position. 2.Control circuit ATS will be active in an instant. After the conversion is complete, the coils in the control circuit are disconnected by the internal converter. The coil can operate normally with a rated voltage of 80%~110%, and too low voltage may cause the coil to heat up or even ignite.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: CB Class ATS Automatic Transfer Switch 200ms ATS Automatic Transfer Switch Fast Changeover ATS Automatic Transfer Switch |
![]() |
63A 220V ATS Automatic Transfer Switchs Dual Power Motor Type |
![]() |
220V 100 Amp Dual Power Automatic Power Transfer Switch ATS PC Class |
![]() |
220V 100 Amp Dual Power ATS Automatic Transfer Switch ICD LCD Controller |
![]() |
Double Power 125A ATS Automatic Changeover Switch CB Level |
![]() |
CE Excitation Dual Power ATS Automatic Transfer Switch 3P For Generator |
![]() |
Double Power 3 Phase AC CB Class 63a 125a Automatic Changeover Switch |