ODM 12V LiFePO4 Battery Lithium Iron Phosphate Batteries Replacement
|
|
The SOETECK SY-Li Series 12V Lithium Iron Phosphate (LiFePO4) Battery is your trusted backbone for reliable backup power and energy storage in critical scenarios. Delivering uncompromising safety, a longer service life, and rock-solid performance, it is engineered to replace outdated lead-acid batteries and perfectly satisfy the rigorous power needs of UPS systems, data centers, communication base stations, and off-grid energy storage setups. Equipped with premium high-purity LiFePO4 cathode materials and a smart integrated Battery Management System (BMS), this battery achieves over 2000 charge-discharge cycles (80% DOD) and works safely even in harsh temperatures (-20°C to 60°C). What’s more, it features zero heavy metal pollution, high energy density, and a minimal self-discharge rate (<3%/month) — offering a cost-effective, eco-friendly power solution that maximizes long-term value for your critical power infrastructure. Product Family
Product Features> High Safety LiFePO4 CoreAdopts high-purity lithium iron phosphate (LiFePO4) cathode material with intrinsic thermal stability—no thermal runaway risk even under short circuit, overcharge, or puncture. Integrated BMS (Battery Management System) provides 7-layer protection (overcharge, over-discharge, over-current, short circuit, over-temperature, under-temperature, balance protection) to ensure safe operation in critical power environments. Ultra-Long Cycle LifeBoasts a cycle life of over 2000 times at 80% Depth of Discharge (DOD), retaining ≥80% of initial capacity—5x longer than traditional lead-acid batteries (300-500 cycles). Under shallow discharge (30% DOD), cycle life extends to 3000+ times, reducing replacement frequency and total cost of ownership (TCO) by up to 60% over 10 years. FEATURED serieS OF Power Distribution SOLUTIONSFocus on the core power delivery demands of high-density data center deployments, where our full range of premium products leverages advanced technological advantages to reliably safeguard continuous, efficient, and stable operation. >> > >Reliable & Cost-Effective Basic PDUs>Robust rack-mount power distribution featuring 2.00mm thick profiles and high-purity red copper bars. Ensures low temperature rise (<3°C) and superior structural stability for general IT equipment. > >Customized / 0U Vertical Functional PDUs>Tailored for high-density environments with customized vertical 0U installation. Features high-power air circuit breakers and hot-swappable modules to support flexible and safe power expansion. > >Networked / Monitored Smart PDUs>Advanced Smart-K series for remote management. Monitors voltage, current, and energy in real-time while integrating environmental sensors (temp/humidity) to optimize PUE and ensure mission-critical uptime. > Intelligent / Centralized Precision PDCs>Intelligent Power Distribution Cabinets designed for modular data centers. Integrates precision circuit monitoring, isolation transformers, and smart management for central power control and safety. APPLICATIONSFrom remote outdoor fields to high-density AI computing centers, our prefabricated and modular designed data center solutions deliver rapid deployment and optimal PUE across diverse industries. >>>> FAQ1. What are the key advantages of LiFePO4 battery over traditional lead-acid batteries?Compared to lead-acid batteries, SY-Li Series LiFePO4 batteries
offer 5x longer cycle life (2000+ vs. 300-500 cycles), 30% lighter
weight (high energy density: 120Wh/kg), zero heavy metal pollution
(eco-friendly), lower self-discharge rate (<3%/month vs.
10-15%/month), and no acid leakage risk. They also perform better
in extreme temperatures and require minimal maintenance, reducing
long-term costs. 2. What is the capacity retention and service life of the battery?At 80% Depth of Discharge (DOD), the battery retains ≥80% of
initial capacity after 2000 cycles; at 50% DOD, it retains ≥80%
capacity after 2500 cycles; at 30% DOD (shallow discharge), cycle
life exceeds 3000 cycles. Under normal operating conditions (room
temperature, 50% DOD, regular charging), the service life is 8-10
years, compared to 2-3 years for lead-acid batteries. 3. What safety protection features does the integrated BMS provide?The built-in BMS offers 7-layer comprehensive protection: (1)
Overcharge protection (cut-off at 14.6V); (2) Over-discharge
protection (cut-off at 10.0V); (3) Over-current protection (10A for
10Ah model, 20A for 20Ah model); (4) Short circuit protection
(instant cut-off within 1ms); (5) Over-temperature protection
(cut-off above 60°C); (6) Under-temperature protection (charging
disabled below 0°C); (7) Cell balance protection (maintains voltage
difference <20mV between cells). 4. What applications is the 12V LiFePO4 battery suitable for?It is widely used in critical power and energy storage scenarios,
including: UPS backup power systems (data centers, server rooms),
communication base stations, off-grid solar/wind energy storage,
emergency lighting, medical equipment backup, RV/camping power
supplies, and industrial control systems. It is compatible with
most standard 12V power devices and UPS brands. 5. What are the charging requirements and maintenance precautions?Charging requirements: Use a LiFePO4-specific charger (constant
current-constant voltage, CC-CV) with charging voltage 14.2-14.6V
and charging current ≤0.5C (e.g., 5A for 10Ah battery). Avoid using
lead-acid chargers (overcharging risk). Maintenance precautions:
(1) Store in a dry, ventilated environment (10-30°C) if unused for
long periods; (2) Recharge to 50-70% capacity every 3 months to
prevent deep discharge; (3) Avoid short circuit, puncture, or
exposure to open flame; (4) No need for water addition or acid
level checks (maintenance-free). 6. Can multiple batteries be connected in series or parallel for higher voltage/capacity?Yes. For higher voltage: Connect up to 4 batteries in series
(12V×4=48V) to match UPS or inverter requirements. For higher
capacity: Connect up to 4 batteries in parallel (e.g., two 10Ah
batteries in parallel = 20Ah capacity). Note: Ensure all batteries
are from the same model, same batch, and have similar voltage
(difference <0.2V) before connection. Use dedicated
series/parallel connectors and avoid overloading the total current. Have more questions about our Liquid Cooling Solutions?Contact Us Now
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: ODM 12v lifepo4 battery 12v lifepo4 battery Replacement ODM lithium phosphate battery 12v |
|
Deep Recycle 2V Gel AGM Lithium Battery For Telecom & Energy Storage |
|
ODM 12V LiFePO4 Battery Lithium Iron Phosphate Batteries Replacement |
|
12V AGM Absorbed Glass Mat Batteries For Telecom & Energy Storage |
|
Lithium Iron Phosphate 48V Telecom Battery Backup Rack Mounted |
|
DOD 12V Gel AGM Lithium Battery Lithium Ion Battery Leakproof |
|
Industrial 2V Telecom Gel AGM Lithium Battery Deep Cycle |