Lithium Iron Phosphate 48V Telecom Battery Backup Rack Mounted
|
|
The SOETECK SY-Li Series Rack-Mounted 48V Lithium Iron Phosphate (LiFePO4) Battery is a high-performance, space-efficient power solution built for modern critical power infrastructure, and a superior upgrade to conventional 48V lead-acid battery banks. Optimized for 19-inch standard server rack installations, it delivers reliable performance for data centers, telecom base stations, edge computing facilities and industrial UPS systems alike. Equipped with premium automotive-grade LiFePO4 cells and an integrated intelligent BMS, it features a 48V nominal voltage (51.2V full charge) with configurable capacities of 100Ah to 500Ah, and allows parallel expansion up to 16 units for scalable energy storage needs. With an exceptional cycle life of 4000+ cycles (80% DOD), rapid 0.5C charging that recovers 80% capacity in 2 hours, and a completely maintenance-free design, it achieves a 50% TCO reduction compared to 48V lead-acid batteries across a 10-year service life. It also delivers dramatic space and weight savings, with 60% less rack footprint and a 70% lighter profile for streamlined deployment. Product Family
Product Features> Intelligent BMS & Multi-Layer Safety ProtectionIntegrated high-precision BMS (Battery Management System) with real-time monitoring of cell voltage, current, temperature, and SOC (State of Charge). Provides multi-layer protection: overcharge/over-discharge protection (42V cut-off / 58.4V cut-off), overcurrent/short-circuit protection, overtemperature/undertemperature protection (-20°C to 60°C), and cell balancing to ensure uniform charging/discharging. Supports RS485/Modbus/CanBus communication for remote monitoring and control via central management systems. Fast Charging & Wide Temperature AdaptabilitySupports 0.5C fast charging (e.g., 50A charge current for 100Ah battery), recovering 80% capacity in 2 hours and 100% capacity in 3 hours (3x faster than 48V lead-acid). Operates reliably in extreme temperatures (-20°C to 60°C discharge, 0°C to 45°C charge), suitable for outdoor telecom base stations and harsh industrial environments. Low self-discharge rate (<1%/month at 25°C), no regular charging required during storage. FEATURED serieS OF Power Distribution SOLUTIONSFocus on the core power delivery demands of high-density data center deployments, where our full range of premium products leverages advanced technological advantages to reliably safeguard continuous, efficient, and stable operation. >> > >Reliable & Cost-Effective Basic PDUs>Robust rack-mount power distribution featuring 2.00mm thick profiles and high-purity red copper bars. Ensures low temperature rise (<3°C) and superior structural stability for general IT equipment. > >Customized / 0U Vertical Functional PDUs>Tailored for high-density environments with customized vertical 0U installation. Features high-power air circuit breakers and hot-swappable modules to support flexible and safe power expansion. > >Networked / Monitored Smart PDUs>Advanced Smart-K series for remote management. Monitors voltage, current, and energy in real-time while integrating environmental sensors (temp/humidity) to optimize PUE and ensure mission-critical uptime. > Intelligent / Centralized Precision PDCs>Intelligent Power Distribution Cabinets designed for modular data centers. Integrates precision circuit monitoring, isolation transformers, and smart management for central power control and safety. APPLICATIONSFrom remote outdoor fields to high-density AI computing centers, our prefabricated and modular designed data center solutions deliver rapid deployment and optimal PUE across diverse industries. >>>> FAQ1. What is the key difference between 48V rack-mounted lithium battery and 48V lead-acid battery?48V lithium batteries outperform lead-acid in core metrics: (1) Cycle life: 4000+ cycles (80% DOD) vs. 800 cycles for lead-acid; (2) Energy density: 140Wh/kg vs. 45Wh/kg (70% weight reduction for same capacity);
(3) Charging speed: 80% capacity in 2hrs vs. 8hrs for lead-acid; (4) Space efficiency: 60% less rack space; (5) Maintenance: Zero maintenance vs. regular watering/checks for flooded
lead-acid. Lithium has higher upfront cost but 50% lower TCO over
10 years due to longer lifespan and lower operational costs. 2. What is the cycle life and service life of 48V rack-mounted lithium battery?At 80% Depth of Discharge (DOD), cycle life is 4000+ cycles (retains ≥80% capacity); at 50% DOD (standby use), it extends to
6000+ cycles; at 100% DOD, cycle life is 2500 cycles. Under normal
operating conditions (25°C, float charge voltage 53.5V), the
service life is 10-12 years (2x longer than 48V AGM lead-acid). At 35°C, service life reduces
to 8-9 years due to accelerated cell aging, but still 1.5x longer
than lead-acid at same temperature. 3. What are the charging requirements for 48V rack-mounted lithium batteries?For 48V (51.2V nominal) LiFePO4 batteries: (1) Float charge
voltage: 53.5-54.0V (25°C); (2) Cycle charge voltage: 56.0-58.4V (25°C); (3) Max charging current: 0.5C (e.g., 50A for 100Ah
battery, 250A for 500Ah battery). Temperature compensation: -8mV/°C
(e.g., 52.7V float charge at 30°C). Use lithium-specific CC-CV
chargers (not lead-acid chargers) to avoid overcharging (voltage
>58.4V) which damages cells and triggers BMS protection
shutdown. 4. How to install and expand 48V rack-mounted lithium battery systems?Installation: (1) Fits 19-inch standard racks (2U/3U/4U models),
requires minimum 600mm depth rack; (2) Plug-and-play connection via
standard power connectors (no hard wiring); (3) Ensure rack
ventilation (airflow ≥0.5m/s) for heat dissipation. Expansion: (1)
Parallel connection up to 16 units (max 8000Ah total for 500Ah
units); (2) Series connection for higher voltage (2 units for 96V,
4 units for 192V); (3) All units must be same model/batch, BMS
firmware version, and initial SOC (±5%) to avoid uneven
charging/discharging. 5. What communication protocols does the BMS support and how to monitor the battery?The integrated BMS supports RS485 (Modbus RTU), CanBus, and optional TCP/IP (Modbus TCP) for remote monitoring. Key monitored parameters: cell voltage
(±5mV precision), total voltage, charge/discharge current,
temperature (±1°C precision), SOC (±3% precision), and fault codes
(overtemp, overcurrent, low SOC). Compatible with mainstream data
center/telecom monitoring systems (e.g., Huawei NetEco, APC
InfraStruxure) for real-time alerts and historical data tracking. 6. What applications are 48V rack-mounted lithium batteries suitable for?48V rack-mounted lithium batteries are optimized for space-constrained, high-reliability critical power scenarios: (1) Data center UPS systems (19-inch rack integration); (2) 4G/5G
telecom base stations (outdoor/indoor cabinets); (3) Edge computing
facilities (small footprint requirement); (4) Industrial UPS
(cyclic load with fast recharge); (5) Renewable energy storage
(solar/wind 48V systems). They are not recommended for low-voltage
(12V/24V) small-scale applications (use 12V lithium batteries
instead). Have more questions about our Liquid Cooling Solutions?Contact Us Now
|
||||||||||||||||||||||||||||||
| Product Tags: Lithium 48v telecom battery Rack Mounted 48v telecom battery 48V telecom backup batteries |
|
Deep Recycle 2V Gel AGM Lithium Battery For Telecom & Energy Storage |
|
ODM 12V LiFePO4 Battery Lithium Iron Phosphate Batteries Replacement |
|
12V AGM Absorbed Glass Mat Batteries For Telecom & Energy Storage |
|
Lithium Iron Phosphate 48V Telecom Battery Backup Rack Mounted |
|
DOD 12V Gel AGM Lithium Battery Lithium Ion Battery Leakproof |
|
Industrial 2V Telecom Gel AGM Lithium Battery Deep Cycle |