China Data Center Air Conditioner manufacturer
HEFEI SHUYI DIGITAL POWER CO.,LTD
China Professional Digital Power Provider
1
Home > Products > AGM Lithium Battery >

DOD 12V Gel AGM Lithium Battery Lithium Ion Battery Leakproof

DOD 12V Gel AGM Lithium Battery Lithium Ion Battery Leakproof

Brand Name Soeteck
Model Number 1
Certification CE, ISO, UL
Place of Origin China
Minimum Order Quantity 1
Price asdfadfdasf
Payment Terms D/A
Supply Ability asdfasdfa
Delivery Time fasdfasdf
Packaging Details sdfasdfasdfasd
Number Of Outlets 4 to 12
Power Capacity 500VA to 3000VA
Transfer Time Typically 2-10 milliseconds
Dimensions Varies by model, typically 150x350x200 mm
Waveform Sine wave or Simulated sine wave
Backup Time 5 to 60 minutes depending on load
Type Power Backup Device
Weight 5 to 15 kg
Battery Type Sealed Lead Acid (SLA) or Lithium-ion
Output Voltage 220-230V AC
Communication Ports USB, RS-232, or Network Management Card
Operating Temperature 0°C to 40°C
Input Voltage 100-240V AC
Noise Level Less than 40 dB
Total Number of Cabinets 1
Available Space for IT Equipment 21-151u
UPS Capacity Edge sites, remote offices, harsh environments
Cooling Type Integrated liquid cooling or air cooling
Cooling Capacity High
Dimensions (W*D*H) Less than or equal to 1.2
Detailed Product Description

The SOETECK SY-VRLA Series 12V Gel Battery is your go-to choice for reliable, low-maintenance backup power in critical scenarios. Leveraging cutting-edge gel electrolyte technology, it delivers exceptional deep-cycle performance and 100% leak-proof operation — making it a superior alternative to outdated flooded lead-acid batteries. It seamlessly fulfills the steady power needs of UPS systems, communication base stations, solar energy storage setups, and emergency power supplies.

Built with premium high-purity lead-calcium alloy grids and thixotropic gel electrolyte, this battery eliminates acid layering and leak concerns, allowing flexible installation in any orientation (vertical/horizontal). With a deep-cycle life of up to 500 charge-discharge cycles (100% DOD) and a minimal self-discharge rate (<2%/month at 25°C), it offers a cost-effective, durable power solution that delivers long-term reliability and value for your standby and cyclic discharge needs.

 

Product Family

ModelsNominal VoltageRated CapacityLength (mm)Width (mm)Height (mm)Total Height (mm)Appox.Weight (kg)
SY-GJM12055 12V55Ah (10hrs/25℃)35016717917919.0
SY-GJM12090 12V90Ah (10hrs/25℃)33017121522029.5
SY-GJM12105 12V105Ah (10hrs/25℃)41017622422435.5
SY-GJM12120 12V120Ah (10hrs/25℃)48217024024044.5
SY-GJM12135 12V135Ah (10hrs/25℃)48217024024046.0
SY-GJM12160 12V160Ah (10hrs/25℃)53020721522059.0
SY-GJM12180 12V180Ah (10hrs/25℃)52223821822363.0
SY-GJM12200 12V200Ah (10hrs/25℃)52026920320870.0
SY-GJM12220 12V220Ah (10hrs/25℃)52126922022572.5
 

Product Features

 

Advanced Gel Electrolyte Technology

Adopts thixotropic silica gel electrolyte that immobilizes sulfuric acid, eliminating acid stratification and leakage risks common in flooded lead-acid batteries. The gel structure enhances ion conductivity (≥100 mS/cm at 25°C) and thermal stability, ensuring consistent performance even under deep discharge (100% DOD) and extreme temperature fluctuations.

 

Maintenance-Free & Leak-Proof Design

Constructed with sealed ABS casing and one-way pressure relief valve, it requires zero watering or electrolyte level checks over its lifespan. The leak-proof design supports vertical/horizontal mounting (±90°), making it suitable for confined spaces in data centers, communication cabinets, and mobile power systems with limited installation flexibility.

FEATURED serieS OF Power Distribution SOLUTIONS

 

Focus on the core power delivery demands of high-density data center deployments, where our full range of premium products leverages advanced technological advantages to reliably safeguard continuous, efficient, and stable operation.

Reliable & Cost-Effective

Basic PDUs

Robust rack-mount power distribution featuring 2.00mm thick profiles and high-purity red copper bars. Ensures low temperature rise (<3°C) and superior structural stability for general IT equipment.

Customized / 0U Vertical

Functional PDUs

Tailored for high-density environments with customized vertical 0U installation. Features high-power air circuit breakers and hot-swappable modules to support flexible and safe power expansion.

Networked / Monitored

Smart PDUs

Advanced Smart-K series for remote management. Monitors voltage, current, and energy in real-time while integrating environmental sensors (temp/humidity) to optimize PUE and ensure mission-critical uptime.

Intelligent / Centralized

Precision PDCs

Intelligent Power Distribution Cabinets designed for modular data centers. Integrates precision circuit monitoring, isolation transformers, and smart management for central power control and safety.

APPLICATIONS

 

From remote outdoor fields to high-density AI computing centers, our prefabricated and modular designed data center solutions deliver rapid deployment and optimal PUE across diverse industries.

AI Model Training & Inference
IDC Capacity Expansion
Mining & Oil Exploration
Server Room Retrofit

FAQ

 
1. What is the cycle life and service life of SY-VRLA Gel Battery?
At 100% Depth of Discharge (DOD), cycle life is 500 cycles (retains ≥80% capacity); at 80% DOD, it extends to 800 cycles; at 50% DOD (typical standby use), cycle life reaches 1200+ cycles. Under normal operating conditions (25°C, 50% DOD, regular float charging), the service life is 5-7 years, compared to 3-4 years for standard flooded lead-acid batteries.
2. What are the charging requirements for Gel batteries?
Gel batteries require a dedicated constant current-constant voltage (CC-CV) charger with: (1) Float charge voltage: 13.5-13.8V (25°C); (2) Cycle charge voltage: 14.1-14.4V (25°C); (3) Charging current ≤0.2C (e.g., 2A for 10Ah battery). Avoid overcharging (voltage >14.7V) as it causes gel electrolyte dehydration and permanent capacity loss. Temperature compensation: -3mV/°C per cell (e.g., 13.2V float charge at 0°C).
3. Can Gel batteries be used in solar energy storage systems?
Yes, SY-VRLA Gel batteries are ideal for solar off-grid/hybrid systems due to: (1) Excellent deep-cycle performance (500 cycles at 100% DOD) for daily charge-discharge cycles; (2) Low self-discharge (<2%/month) for long idle periods in low-sunlight seasons; (3) Wide temperature adaptability (-15°C to 50°C discharge) for outdoor solar installations. They are compatible with most solar charge controllers (PWM/MPPT) with gel battery charging profiles.
4. What are the storage conditions and shelf life of unused Gel batteries?
Unused batteries should be stored in a dry, ventilated environment (10-30°C, humidity 40-70%) with 50-70% initial capacity. Shelf life is 12 months at 25°C (capacity retention ≥80%); at 35°C, shelf life reduces to 6 months. Recharge to 100% capacity every 6 months during storage to prevent sulfation and permanent capacity loss. Avoid storage in temperatures >40°C or direct sunlight.
5. What applications are SY-VRLA Gel batteries suitable for?
They are widely used in critical and cyclic power scenarios: UPS backup power (data centers, server rooms), communication base stations (4G/5G towers), solar/wind off-grid energy storage, emergency lighting systems, medical equipment backup, marine/RV power supplies, and industrial control systems. They are particularly suitable for applications requiring maintenance-free operation and leak-proof performance in confined spaces.

Have more questions about our Liquid Cooling Solutions?

Contact Us Now

 

 

 

 

Product Tags: DOD AGM Lithium Battery   leakproof AGM Lithium Battery   12V telecom lithium ion battery  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: HEFEI SHUYI DIGITAL POWER CO.,LTD
Subject:
Message:
Characters Remaining: (80/3000)