Electric Chitherm Bf260-16 High Temp. Bell Furnace for Air
Atmosphere and Electric Fuel at High Temperature 1. Application: Widely used in the adhesive sintering process of zirconia ceramics,
magnetic materials, electronic ceramic components and other
products.
2. Technical Specification:- Rated Temp.:1500ºC
- Max Temp.:1600ºC
- Effective Dimensions:720mm*500mm*720mm(D*W*H)
- Heating Method:MoSi2 heating element
- Thermcouple:B-Type
- Temperature Control: 1 Point
- Temp. Set Accuracy: ±1ºC(flat temp. insulation)
- Temp. Control Mode:The Japanese Daiwa Chino Programmable Temperature Controller
features PID auto-tuning functionality.
- Temp. Uniformity: ± 5ºC (empty furnace insulation test
2hours under 1500ºC) .
- Maximum Heating Power:85kW
- Insulation Power:≤40kW
- Program Control: SCR Control Module;
- Lifting Mechanism: Lead Screw Drive Elevation System;
- Control Method: Phase Angle Control;
- Operating Atmosphere: Air;
- Exhaust System: Top-mounted exhaust stack for effluent discharge;
- Protection Functions: Audible & visual alarm system for
over-temperature, motor overload, and over-travel conditions;
- External Dimensions: 1950*3600*3100mm(D*W*H) (without control
cabinet)
- Appearance Color: Light gray.
3. Delivery ListTable 1 Delivery list | | Item | Note | Qty. | Basic Components | Furnace | | 1 SET | Inspection Certificates | Certificates of major outsourced components | 1 SET | Technical Documents | Instructions, technical documents of the major outsourced parts,
etc | 1 SET | Control Cabinet | 1000*2000*600mm(W*H*D) | 1 SET | Key Components | Silicon molybdenum rod | | 1 SET | Thermocouple | B-Type | 1 SET | Temperature controller | Japanese Daiwa Chino | 1 SET | Spare Parts | Heating Element | Silicon molybdenum rod | 1 PC |
4.Equipment Normal Operating Conditions- Environmental Conditions: temperature: 0~40ºC, humidity≤ 80%RH, no
corrosive gas, no strong airflow disturbance;
- Atmosphere Conditions: dry, clean, oil-free compressed air, working
pressure of 0.2- 0.4MPa, gas consumption of 10 - 30 m3/h;
- Ventilation System: non-contact access to the user pumping system,
pumping capacity is greater than 30 m3/h
- Ground Requirements: horizontal, no obvious vibration,
load-bearing> 500 Kg/m2;
- Power Condition(TBD): capacity > 120kVA, 3-phases 5-lines, voltage 220 / 380V, frequency 50Hz. Fire
line: yellow, green, red, Zero line: blue, Ground line:
yellow-green;
- Installation Site:4000mm*3500mm*4000mm(D*W*H), with an installation area greater than 14m2.
|