China Vibration Test System manufacturer
Labtone Test Equipment Co., Ltd
Vibration and Shock Test Equipment for over 20 years
9
Home > Products > Vibration Table Testing Equipment >

Air Cooling Shock And Vibration Test Equipment For Package ISO 13355

Browse Categories

Labtone Test Equipment Co., Ltd

City: dongguan

Province/State:guangdong

Country/Region:china

Tel:86-769-85370090

Contact Person:
Mr.Labtone
View Contact Details

Air Cooling Shock And Vibration Test Equipment For Package ISO 13355

Brand Name LABTONE
Model Number EV450
Certification SGS CE / ISTA / ISO
Place of Origin Dongguang, China
Minimum Order Quantity 1 Set
Price Negotiable
Payment Terms T/T, L/C
Supply Ability 15 Sets / Month
Delivery Time 45 Working Days
Packaging Details Plywood Case with Vacuum Packing
Sine Force Peak 5000kg.f
Random Force 5000kg.f
Frequency Range DC-3000 Hz
Software Sine, Random, Shock
Control Computer Acer
Displacement 100mm p-p
Payload 500kg or more
Head Expander Magnesium Alloy
Detailed Product Description

 

Air Cooling Shock And Vibration Test Equipment For Package Test ISO-13355

 

 

Vibration testing simulates the vibration conditions that a product might experience during its lifetime but under a controlled and repeatable test environment. Vibration tests are conducted in an accredited vibration testing lab to ensure that finished products can perform safely during operation or transit and to avoid unexpected performance issues or early failure during use. Because products spend their lifetime in different environments and these environments exhibit unique vibration profiles, our vibration testing services are tailored to fit each unique environment with specific vibration control profiles.

 

Vibration Shaker System Specifications: EV450

Shaker Specifications A50F44
Peak Sine (Pk)5000Kg.f peak (50KN)
Random (RMS)5000Kg.f r.ms (50KN) @ISO5344
Shock (Pk)10000Kg.f peak (100KN) @6ms
Usable Frequency1~2500Hz
Maximum Displacement (p-p)100mm (4inch) intermittence, 80mm (3inch) continuous
Max. velocity2m/s
Max. accelerationSine:83g (813 m/s2);Random: 60g (588 m/s2)
Vertical Load Support500 kg

Body Suspension Natural

Frequency (Thrust Axis)

Less than 2.5 Hz
Armature DiameterФ440 mm
Armature Weight50 kg

Fundamental Resonance

Frequency (Bare table)

2,100 Hz (nom.) +/- 5%

Load Attachment

Points (Standard)

16 stainless steel M10 Inserts
Stray Flux Density<10gauss
Allowable partial force1000.N.M
Shaker dimensions1670L x 1150D x 1300H mm
Weight of ShakerAbout 4600Kg
Power Amplifier Specifications LA50K
Rated Output Capacity50KVA
Signal to Noise RatioGreater than 65 dB
Amplifier EfficiencyGreater than 90%
Amplifier Overall Dimensions650mmL×920mmD×2100mmH
Weight of AmplifierAbout 560Kg
Interlock Protection●Input Over/Under Voltage ●Logic Fault ●Output Over Voltage/Current ●Control Power ●External ●Shaker Oil Pressure ●Module O/T ●Shaker Temp ●Shaker Travel

 

The model selection of the vibration test system has the following steps:


1. Determine the test frequency range and limit peak motion (acceleration, velocity and displacement) according to the test conditions.


2. Determine the mass (DUT) of the item under test and the dimensions of the mounting surface required to bolt the DUT to a shaker table with its center of gravity (CG) over the table’s center. This may require use of a head expander and/or other mounting fixture. Determine the mass of such additional hardware including all mounting fasteners.

 

Look at the shaker specifications for the test system. Verify that the mass of the part under test and any mounting fixture is less than the maximum static load rating of the shaker. Verify that the component under test (or its mounting hardware) can be bolted to the shaker armature or head expander. Add the effective armature mass and expansion head mass to the mass of the object under test as well as the mass of any mounting clamps and fasteners and the mass of any accelerometers mounted on the object under test -- this is the total moving mass the shaker must move during the test. Multiply the total moving mass by the acceleration determined in step 1 to calculate the force required. Verify that the test and DUT required to determine the test frequency range, force, peak acceleration, peak velocity, and peak displacement is less than the corresponding performance rating of the selected shaker system. If this is true, the shaker chosen is acceptable. If not, a more powerful shaker is required.

 

 

 

Working Principle:

 

 

 

Application:

 

 

 

 

Services:

  • Uptime is paramount: We strive to ensure rapid, high-quality service and support
  • Dialogue: We are committed to responding promptly to all customer requests and questions and to keeping customers informed regarding service and support status so they can plan efficiently
  • Skilled team of technicians and engineers: Our staff continuously receives the latest training in order to deliver the best possible service and support
Product Tags: MgAL Vibration Test Equipment   Vibration Testing Equipment 5000kg.f   ISO 13355 Vibration Table Testing Equipment  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Labtone Test Equipment Co., Ltd
Subject:
Message:
Characters Remaining: (80/3000)