Hot Flaming Oil Tester , Hot Flaming Oil Flammability Test Chamber
IEC 60950 Annex A.3
Product overview:
The hot flaming oil test device conforms to IEC60950-1:2005 and
IEC60950-1:2013 clause 4.6.2, Annex A.3. It is used to simulate
that the flammable liquids used in electrical and electronic
equipment may ignite due to overheating and leak out of the fire
protection enclosure, causing electrical fires and endangering the
reliable operation of the equipment and personal safety.
Test principle:
Fill 10mL of flammable liquid with the specified performance
(average calorific value 38MJ/L, mass per unit volume between:
0.845g/mL~0.865g/mL, flash point: 43.5℃~93.5℃) in the metal ladle,
after heating to the distillate fuel oil’s ignition point and
burning 1mim, the motor drives the spoon to rotate at a certain
height (100mm) and a certain flow rate (1mL/s), and then steadily
pour the flammable liquid on the center of the opening of the
sample (fire protection enclosure). The fire protection performance
of the test product is evaluated by whether the ignition bedding at
the specified distance (50mm) and with the specified density
(40g/m2) under the test product is ignited.
Technical parameters:
| Parameter model | KP-FT06 |
| Working voltage | Match client's local power supply requirements |
| Test oil | Average calorific value 38MJ/L, mass per unit volume between:
0.845g/mL~0.865g/mL, flash point: 43.5℃~93.5℃ |
| Volume of ladle | >10mL |
| Hot flaming oil burning time | 1 min (1s~99999s can be preset) |
| Hot flaming oil pouring speed | 1 ml/s |
| Hot flaming oil pouring height | 100mm |
| Hot flaming oil pouring time | 10s (1s~99999s can be preset) |
| Ignition bedding material | Bleached CHEESECLOTH of approximately 40 g/m² |
| Distance between ignition bedding material and sample | Ignition bedding material is under the sample about 50mm |
| Test area background color | Black |
| Equipment size & weight | 1150mm* 750mm* 1350mm,150kg |