IEC60598-1 IEC60112 Materials Flame Test Equipment Proof Tracking Index Tester High Accuracy
|
Tracking Tester
Brief Introduction
Technical Parameter
3.Test procedure
* this tester should be placed on a level table * table size no less than 1500W * 900D * (600-800)H mm * distance to the wall: > 200mm * exhaust pipe: diameter of 100mm * the test room should be independent room equipped with exhaust system and firefighting device
Preparation 2.1) install the exhaust pipe, tighten the fitting 2.2) check the power supply wiring, ensure it’s correct and grounded 2.3) make up test resolution, and adjust the dropping device accord to standard requirements of:
Drops of solution fall on to the specimen at intervals of 30±5s; The drops shall fall more or less centrally between the electrodes from a height of 35±5mm; The time for 50 drops to fall on to specimen shall be 24.5±2min; The mass of a sequence of 50 drops shall lie between 0.997g and 1.147g; The mass of a sequence of 20 drops shall lie between 0.380g and 0.480g. Attention: Solution prepared should be used within 4 hours to ensure conductivity qualified. Filling the solution after its full melted, preventing particles clog pipes. Emptying the liquid when test finished, and wash the pipe with water.
2.4) specimen preparation The specimen should be flat and clean, flat surface no less than 20mm*20mm, thickness of specimen shall be 3mm or more. 2.5) electrode installation Adjust the angle(60±5°)and distance(4±0.1 mm) between two electrodes; Adjust the pressure by move the weight to 1±0.05N; Fix the screws, and close the window.
Set test parameters Power on, you can see the welcome interface on touchscreen, it will go operation interface automatically in 3s. 【power】, click power and rotate the voltage regulator, to preset the test voltage 【drip】, click drip, resolution drips, and the counter counts 【exhaust】, click to control the fan 【light】, click to control the light 【short】, click short and rotate the current regulator, preset short-circuit current as 1.0A 【start】, click start, enter testing mode. Tester will stop automatically when the current over 0.5A for 2s
Attention
Tracking Tester instruction manual
|
||||
Product Tags: Needle Flame Tester Needle Flame Test Apparatus |
![]() |
Needle Flame Tester , 50 W flames tester , 500W flames tester, Flammability Testing Equipment |
![]() |
Needle Flame Tester ,IEC60695-11-5 Flammability Testing Equipment |
![]() |
Glow wire test apparatus, glow wire tester without test chamber , IEC 60695-2-10 Glow Wire Tester , |
![]() |
IEC60695-11-5 Flammability Tester Needle Flame Tester |
![]() |
Glow Wire Tester, IEC60695-2-10 Flammability Testing Equipment ,Glow-wire apparatus |
![]() |
FAA-Vertical Bunsen Burner Test For Cabin And Cargo Compartment Materials Flammability Test Chamber |