Small Compression Load Cell 50kg Miniature Compression Force Sensor
500N
Miniature Compression Type Load Cell FCLB is made of
stainless steel based on strain gauge technology which offers 5kg /
10kg / 20kg / 50kg / 100kg / 200kg / 500kg seven rated capacities
to choose from,compact design makes button type load cell FCLB
suitable for compression force measurement applications with
limited mounting space. Each sensor comes with a 3-meter-long
shielded cable, 4xM2.5 threaded holes located on the bottom make it
easy to mount force sensor FCLB to a flat platform,you may find
Miniature Force Transducer FCLB suitable for applications such as
load distribution analysis, mold pressure measurement, force
overload protection, clamping force measurement, assembly force
monitoring, hydraulics force control and so on.
A force sensor is a transducer that converts force acting on it
into electronic signal which is proportional to the applied
force.The acting force causes deformation of the measuring
element,the bonded strain gage deforms accordingly which will cause
the resistance change of the wheatstone bridge,under constant power
supply,the output signal between Sig+ and Sig- will change
proportionally,thus the force can be measured by measuring the
output signal from the load cell. Miniature Button Load Cell
FCLB is designed to measure compression force,outputs
millivolt signal ranging 0~20mV, and signal amplification may be
required for most applications, a load cell signal conditioner can
be used to get 0-5V, 0-10V or 4-20mA signal proportional to applied
force.The amplified output then can be easily processed by PLCs and
data acquisition software.The force can be displayed through force
indicator,force meter FPT is integrated with high accuracy/low
noise 24 bit Sigma-Delta ADC,sampling speed up to 960Hz makes it
suitable for both static and dynamic measurement;FPT also supports
Modbus RTU protocol with RS485 or RS232 communication
port,amplified signal 0-5V,0-10V,0-20mV or 4-20mA is also
achievable from FPT.
Dimensions(unit in "mm")
Specifications
Capacity | 50N / 5kg / 10lb 100N / 10kg / 20lb 200N / 20kg / 45lb 500N / 50kg / 110lb 1kN / 100kg / 220 lbf 2kN / 200kg / 450 lb 5kN / 500kg / 1120 lbf |
Rated output | 1.5mV/V |
Excitation | 3-12V |
Zero balance | ±0.1mV/V |
Nonlinearity | ±0.5% of the capacity |
Hysteresis | ±0.5% of the capacity |
Nonrepeatability | ±0.2% of the capacity |
Creep(3min) | ±0.1% of the capacity |
Safe overload | 150% of the capacity |
Ultimate overload | 200% of the capacity |
Compensated temperature | -10...+40oC |
Operating temperature | -20...+60oC |
Temperature shift zero | ±0.05% R.O./oC |
Temperature shift span | ±0.05% R.O./oC |
Input resistance | 1000±100 ohms |
Output resistance | 1000±100 ohms |
Insulation resistance | >5000M ohms |
Ingress protection | IP65 |
Material of element | Stainless steel |
Cable | Ø3*3000mm 4-core shielded cable |
Wiring code | Red--Excitation+ Black--Excitation- Green--Signal+ White--Signal- |
Brief instruction of Rated output(or Sensitivity):
Definition: The signal produced by load cell(or force transducer)
when rated load is applied, expressed in terms of mV/V. The rated
output indicates the output signal range of a sensor.
Sensor output = (Power supply * Rated output) * Load / Capacity
Rated output of Small Button Load Cell FCLB is normally around
1.5mV/V.
Power supply of Small Compression Sensor is normally within 3-12V.
Load / Capacity is within 0-1.
So the output range of Miniature Button Load Cell FCLB is
normally within 0...+18mV for compression load measurement.
Example one: Small Compression Load Cell FCLB-500N with
1.5mV/V sensitivity powered by 10V DC,the output range is
0...+15mV.
Example two: Miniature Compression Sensor FCLB-1kN with
1.5mV/V sensitivity powered by 5V DC,the output range is
0...+7.5mV.
Small Compression Load Cell 50kg Miniature Compression Force Sensor
500N
Click here to download datasheet