Nylon Stainless Steel Test Finger Probe 11 Of Iec 61032

Nylon Stainless Steel Test Finger Probe 11 Of Iec 61032

Brand Name SKYLINE
Model Number SL-P11
Certification CE
Place of Origin China
Minimum Order Quantity 1
Price Negotiable
Payment Terms T/T, L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time 7 Working Days
Packaging Details Export Packaging
Materials Nylon Stainless Steel
Nodular Finger Length 80mm
Nodular Finger Diameter 12mm
Dam-board Diameter 50mm
Dam-board Thickness 5mm
Standard IEC61032-Probe 11-Figure 7
Detailed Product Description

Product Description

The Rigid Test Finger is a precision test probe made according to Figure 7 (Fig. 7) of the IEC 61032 (Test probe 11) and is used to simulate a human finger. It is also used by the standards of IEC 60335, IRAM 4220-1 and in most of the rules involved in the verification of accessibility to live parts.The Rigid Test Finger was made on stainless steel and Polyamide handle.

Applicatiopn 

1.The joint part of The Standard Test Knurled Finger Probe can't touch the live parts or close to the dangerous parts, and 50 mm to 20 mm baffle plate cannot enter.

2.In the prevent electric shock test, wires , power devices, and lighting devices are needed.

3.Both joints shall permit movement in the same plane and the same direction through an angle of 90° with a 0° to +10° tolerance

 

Technical Parameters

Nodular Finger length

80mm

Nodular Finger diameter

12mm

Dam-board diameter

50mm

Dam-board thickness

5mm

Material

delrin and stainless steel

 

NOTE 1:Using the pin and groove solution is only one of the possible approaches in order to limit the bending angle to 90°. For this reason, dimensions and tolerances of these details are not given in the drawing. The actual design must insure a 90° bending angle with a 0° to + 10° tolerance.

NOTE 2: Dimensions in parentheses are for information only.

NOTE 3: The test finger is taken from IEC 60950-1, Figure 2A. That test finger is based on IEC 6103216), Figure 2,test probe B. In some cases, the tolerances are different.

 

 