SL-OA66 Infrared Photometric Oil Meter
Product Description:
The infrared photometric oil measuring instrument is a
high-precision analytical instrument, which adopts an integrated
optical path system with reasonable optical path design, strong
signal and high signal-to-noise ratio. Aluminum alloy casting base,
after natural failure treatment, external power supply, injection
molded shell, beautiful and generous, light in size and weight, it
can be used as a portable instrument as well as a laboratory
instrument.
Technical Features:
Switching power supply, wide power supply range, automatic
switching mechanism between samples and reference cells,
positioning, eliminating errors, and making the influence of
mechanical errors approach zero cosecant mode for wave number
positioning and scanning, so that the wave number positioning
accuracy is less than one wave number and three wave numbers, in
line with "HJ 637” does not need to make a standard curve, only a
set of calibration coefficients is used to simulate the oil
composition in water, and the error of measuring the standard oil
of any component is less than 5%, so that the instrument is
equipped with a meal fume measurement menu for the actual water
sample service, completely according to the diet Oil fume emission
standard GB18483 measurement of oil fume in catering industry.
Chinese menu operation, equipped with a large-screen LCD display ,
no need for calibration of standard samples, measurement results
can be printed out, can be used independently from the computer ,
can be connected to a computer system for operation, the wave
number can be freely compensated and positioned , and can be
quantitatively measured, Qualitative analysis is also possible; the
spectrum is clear and various interfering substances can be
distinguished
Technical Parameters:
Wavenumber scanning range | 3400cm-1~2400cm-1 Wavenumber |
repeatability | ±1cm-1 Wavenumber |
accuracy | ±1cm-1 |
Spectrum resolution | 1 cm-1 |
Absorbance linear range | 0.0000~1.9999 |
Correlation coefficient | r>0.999 ( Infrared non-dispersive method) |
Basic measurement range | 0.02~800mg/L |
Detection concentration | 0.0001mg/L |
Detection concentration | 80000mg/L (dilution measurement) |
Detection limit 3SD | <0.2mg/L |
Baseline drift | <1% /4h |
Measurement error of different proportions | <5% (mixed hydrocarbons in different proportions to simulate
actual water samples) |
Power supply | 220V±10V 50HZ±1HZ |
Humidity | <80% |
Temperature | 5~35°C |
Dimensions | 500×250×150 (mm) |
Weight | 5.5kg |