Endo Gia Minimally Invasive Surgical Linear Stapler And Reloads Elongated
|
endo gia stapler and reloads/ endoscopic stapler and reloads endoscopic cutting stapler
1. Clinical Back Ground
A stapler is a mechanical device, the word "stapler" can actually refer to a number of different devices of varying uses. In addition to joining paper sheets together, staplers can also be used in a surgical setting to join tissue together with surgical staples to close a surgical wound (much in the same way as sutures). Staplers were originally developed to address the perceived problem of patency (security against stenosis or occlusion of the lumen) and tightness (security against leaks of blood or bowel contents) as well as easiness and quickness in performing the anastomosis. Leaks from poor suturing of bowel anastomoses was at that time[when?] a significant cause of post-surgical mortality. More recent studies have shown that with current suturing techniques there is no significant difference in outcome between hand sutured and mechanical anastomoses, but mechanical anastomoses are significantly quicker to perform. The technique was pioneered by a Hungarian surgeon, Humor Hultl, known as the "father of surgical stapling". Hultl's prototype stapler of 1908 weighed eight pounds (3.6 kg), and required two hours to assemble and load. Many hours were spent trying to achieve a consistent staple line and reliably patent anastomoses. The early instruments, by developers including Hultl, von Petz, Friedrich and Nakayama, were complex and cumbersome to use.
2. Contraindications 2.1 Severe mucosal edema 2.2 Do not use the instrument on any tissue that compresses easily to below 1.0mm. In this case it would not be fully tightened to ensure hemostasis 2.3 Do not use the stapler if the diameter of component is larger than the lumen organ’s, or else may lead to suture mouth shrink or straitness. 2.4 Do not use the stapler if there is not enough tissue allow to be overturned to make the staples suture tightly.
The single packaging of Disposable endo cutter stapler adopts blister packing, the middle packaging a box and the outside packing is a corrugated carton.
4. General medical instruments code UMDNS-Code: 【16-771】 GMDN-Code: 【P59871】
5. Product Classification: Class Ⅱb by Rule 8 Annex Ⅸ of MDD 93/42/EEC(2007/47/EC).
Products Inforumation
1.Endoscopic Stapler
1. Q:Are you a factory or trading company? 2. 3.Q:Can you make samples? 6.Q:Can you do OEM for us? 7.Q:Does the price include freight?
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: minimally invasive surgical linear stapler elongated surgical linear stapler endo elongated linear stapler |
![]() |
Laparoscopic Surgery Ultrasonic Harmonic Scalpel |
![]() |
Endo Gia Minimally Invasive Surgical Linear Stapler And Reloads Elongated |
![]() |
Iso 60 Linear Cutter Stapler For Endoscopic Linear Cutter |
![]() |
Endoscopic 160 Surgical Linear Stapler And Rotated Laparoscopic Stapler Cartridge |
![]() |
Laparoscopic Surgery 14cm Ultrasonic Scalpel Harmonic Eto Sterilization |
![]() |
Eto Sterilization Ultrasonic Harmonic Scalpel 23cm Shaft Length |