Surgical Laparoscopic Ultrasonic Scalpel and Ultrasonic Scalpel Shears ETO Sterilization
|
Laparoscopic ultrasonic surgical scalpel full system Introduction: The Ultrasonic Generator System utilizes ultrasonic energy to enable hemostatic cutting and/or coagulation of soft tissue. The system consists of an ultrasonic generator, a foot switch, an optional hand switching adaptor, a hand piece, and a variety of open and minimally invasive instruments. The Ultrasonic instruments vibrate longitudinally at 55.5 kilohertz. This ultrasonic vibration at the blade enhances its cutting ability. The same vibration seals small vessels with coagulated blood and tissue proteins. The generator is a device (or generator) that is used to generate and supply power and output control to an ultrasonic transducer. Activating the footswitch or manual switch adapter provides power output. The generator generates electrical energy signals that are transmitted to the transducer through a cable and the transducer converts the electrical energy signal into mechanical motion of the ultrasonic wave. Indications The HARMONIC System is indicated for soft tissue incisions when bleeding control and minimal thermal injury are desired. The HARMONIC System instruments can be used as an adjunct to or substitute for electrosurgery, lasers, and steel scalpels.
Contradiction The instruments are not indicated for incising bone. The instruments are not intended for contraceptive tubal occlusion.
System Components
Energy Generator The generator supplies the hand piece with electrical energy and facilitates selection of power levels, system monitoring, and system diagnostics. Power is delivered by activating the foot switch or hand switch.
Hand Piece The hand piece contains an acoustic transducer that converts the electrical energy supplied by the generator to mechanical motion. The transducer is connected to an amplifier which amplifies the motion produced by the transducer and relays it to the instrument.
Instrument The mechanical motion from the hand piece advances to the instrument, transmitting ultrasonic energy which enables hemostatic cutting and/or coagulation of tissue.
Power Levels The generator delivers two power levels: minimum (MIN) and maximum (MAX). The minimum power level may be adjusted by the user from Level 1 to 5. The maximum power level is always Level 5. With all instruments except the ball coagulator, use a higher generator power level for greater tissue cutting speed and a lower generator power level for greater coagulation. For the ball coagulator, higher generator power levels will provide greater coagulation. The amount of energy delivered to the tissue and resultant tissue effects are a function of many factors including the power level selected, instrument characteristics, grip force (when applicable), tissue tension, tissue type, pathology, and surgical technique.
FAQ 1. Q:Are you a factory or trading company? 3. Q:Can you make samples? 6. Q:Can you do OEM for us? 7. Q:Does the price include freight? |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: Surgical Laparoscopic Harmonic Scalpel Curved Tip Laparoscopic Harmonic Scalpel ETO Sterilization Laparoscopic Harmonic Scalpel |
![]() |
Laparoscopic Surgery Ultrasonic Harmonic Scalpel |
![]() |
Endo Gia Minimally Invasive Surgical Linear Stapler And Reloads Elongated |
![]() |
Iso 60 Linear Cutter Stapler For Endoscopic Linear Cutter |
![]() |
Endoscopic 160 Surgical Linear Stapler And Rotated Laparoscopic Stapler Cartridge |
![]() |
Laparoscopic Surgery 14cm Ultrasonic Scalpel Harmonic Eto Sterilization |
![]() |
Eto Sterilization Ultrasonic Harmonic Scalpel 23cm Shaft Length |