Flat crane cables, lifter cable, Flat lifter cable, Echu cable factory
|
|
As connecting and control cable for cranes and conveyers. It is suitable for the places of railway stations,crane and other rela
It is suitable as a control and connection cable for cranes and conveyers on building sites,container goods railway stations and dockyards where operating conditions are rough. Structure: Conductor:superfine copper strands acc.to VDE0295,CLASS 5 Insulation:mixed PVC,resistant to oil,flame resistance and self-extinguishing Colour:acc.to 227IEC(brown,blue,black,green/yellow) 5cores or more with black number with white digital coding Sheath:butadiene-acrylonitrile rubber;resistant to oil,flame retardant and self-extinguishing; Colour:black(RAL9005)or grey (RAL7001) Standard:acc.to VDE 0482,part 265-2-1 resp.EN 50265-2-1 and IEC 60332-1.
Technical data: Rated voltage:≤1.5mm 300/500V >1.5mm:450/750V Test voltage: ≤1.5mm 2500V >1.5mm:3000V Mimimum bending radius:0.3m<L<0.6m Burning vertically test:GB/T1 8380.1-2001, IEC 60332-1:1993 test Passedstandard: GB5023.6,IEC60227-6,EN 50214. Used under the normal conditions .the temperature of conductor is lower than 70°C Temperature range:-15°C to +40°C Cables are reommended for installations where the suspended length doesn’t exceed 80m;and the speed of travel does not exceed 4m/s If it is more than this ,with steel
The following cables are usual items. 1.Flat cable 4Cx4mm2 2. Flat cable 4Cx6mm2 3. Flat cable 8Cx1.5mm2 4. Flat cable 12Cx1.5mm2 5. Flat cable 4Cx10mm2 6. Flat cable 4Cx16mm2 7. Flat cable 4Cx25mm2 8. FLat cable 4Cx35mm2 9.Flat cable 8Cx1.25mm2 10.Flat cable 14Cx1.25mm2 It is suitable as a control and connection cable for cranes and conveyers on building sites,container goods railway stations and dockyards where operating conditions are rough. Structure: Conductor:superfine copper strands acc.to VDE0295,CLASS 5 Insulation:mixed PVC,resistant to oil,flame resistance and self-extinguishing Colour:acc.to 227IEC(brown,blue,black,green/yellow) 5cores or more with black number with white digital coding Sheath:butadiene-acrylonitrile rubber;resistant to oil,flame retardant and self-extinguishing; Colour:black(RAL9005)or grey (RAL7001) Standard:acc.to VDE 0482,part 265-2-1 resp.EN 50265-2-1 and IEC 60332-1.
As connecting and control cable for cranes and conveyers. It is suitable for the places of railway stations,crane and other rela
It is suitable as a control and connection cable for cranes and conveyers on building sites,container goods railway stations and dockyards where operating conditions are rough. Structure: Conductor:superfine copper strands acc.to VDE0295,CLASS 5 Insulation:mixed PVC,resistant to oil,flame resistance and self-extinguishing Colour:acc.to 227IEC(brown,blue,black,green/yellow) 5cores or more with black number with white digital coding Sheath:butadiene-acrylonitrile rubber;resistant to oil,flame retardant and self-extinguishing; Colour:black(RAL9005)or grey (RAL7001) Standard:acc.to VDE 0482,part 265-2-1 resp.EN 50265-2-1 and IEC 60332-1.
Technical data: Rated voltage:≤1.5mm 300/500V >1.5mm:450/750V Test voltage: ≤1.5mm 2500V >1.5mm:3000V Mimimum bending radius:0.3m<L<0.6m Burning vertically test:GB/T1 8380.1-2001, IEC 60332-1:1993 test Passedstandard: GB5023.6,IEC60227-6,EN 50214. Used under the normal conditions .the temperature of conductor is lower than 70°C
Temperature range:-15°C to +70°C Cables are reommended for installations where the suspended length doesn’t exceed 80m;and the speed of travel does not exceed 4m/s If it is more than this ,with steel |
|
Echu cable factory, Flat Traveling Cable for Lifter, Flat Crane Cables |
|
Flat crane cables, lifter cable, Flat lifter cable, Echu cable factory, Flat Traveling Cable for Lifter |
|
Flat crane cables, lifter cable, Flat lifter cable, Echu cable factory |
|
Flat Crane Cable ,crane cables,lifter cable, Flat lifter cable, Echu cable factory |
|
Flat Crane Cable ,crane cables,lifter cable, Flat lifter cable, Echu cables |