Name | Operation | State Indicator | Authorization |
【Auto】 | Auto / Manual [Emergency Stop] switch. | Green: Auto state. Grey: Manual state. | All Users |
【Start】 | Start. | Green: Running state. Grey: Stop state. |
【Re-run】 | Clear Alarm & Recover Running. | |
【Stop】 | Normal Stop [Last Batch]. Stop after the present batch finished. | Flashing Red. |
【Pause】 | Pause. | |
【E-stop】 | Emergency Stop. | |
【Alarm】 | Alarm Query / Clear Alarm. ‘Auto/Pause’ state: Recover Running after alarms cleared. | Red: Alarm state. |
【Shift】 | Batching Hoppers/Materials Shift. Mixer in Weighing Hopper Run Selection While Bulk Feeding. Recipe Display Style in Main User Interfaces. | Green/Blue: Selected. Grey: Unselected. |
【Print】 | Report Print: - [ Auto Print]: Print Batch Records.
- [Total]: Print Totalizing Report.
- [Recipe]: Print Working Recipe.
| |
【Lock】 | Screen-locking: Locking/unlocking the operating buttons of main
user interface. Auto Screen-locking: Refer to parameter [901]. | Flashing Red: Locked. Grey: Unlocked. |
【Menu】 | Enter Main Menu. | |
【User】 | User Login. Display: Operator / Engineer / Admin. | |
【Zero】 | Manual Zero [No Power-down Protection]. | Flashing green. |
【Bulk】 | Manual Start/Stop Mn Bulk Feed. | Green: Working state. |
【Drip】 | Manual Start/Stop Mn Dribble Feed. | Green: Working state. |
【Dump】 | Manual Start/Stop Dumping. | Green: Working state. |
【Mn】 | Material Selection for Manual Operation. | |
【MixTank Dump】 | Manual Start/Stop Mixing Tank Dumping. | | |
【Clear】 | Clear Screen: Clear the display values of Feeding Weight, Totalized
Weight and Batch Count’. | | Engineer Administrator |