SITRANS LCS100 SITRANS LCS100 is a point level switch that detects point level in
liquids, solids, slurries, foam, and interface detection. Its
compact design is ideal for confined spaces with plastic or
stainless steel process connections and flexible rod and cable
probe extensions. SITRANS LCS100 is used for overflow, high, low,
and demand applications as well as pump protection. It works in all
types of vessels, pipes, and silos in a broad range of industries
including food, pharmaceuticals, chemical, petrochemical, water,
and machine building. | | | | 7ML700.-.....-.... | 7ML701.-.....-.... | 7ML702-.....-.... | 7ML703.-.....-.... |
Benefits Potted construction provides protection from shock and vibration Factory calibrated to work in most applications without tuning Active shield and tunable to compensate for build-up Optional IO-link communication and remote testing Options for plastic or Stainless steel enclosure and M12 connection Application SITRANS LCS100's flexible insertion length, starting at 92 mm (3.6
inch), and its versatility in various applications and in vessels
or pipes make it a good fit for most point level applications. Its advanced design provides accurate, repeatable, switchpoint
performance. The PPS (Polyphenylene sulfide) probe [optional PVDF
(Polyvinylidene Fluoride)] and optional peek are chemically
resistant with an effective process operating temperature range
from ‑40 to +125 °C (‑40 to +257 °F). The fully potted design
ensures reliability in a vibrating environment such as agitated
tanks. When used with a SensGuard protection cover, the LCS100 is
protected from shearing, impact, and abrasion in tough primary
processes. The SITRANS LCS100 is available with either a stainless steel
enclosure or a polyester enclosure and stainless steel or PPS
process connection options. Key Applications: liquids, slurries, powders, granules, food and
pharmaceuticals, chemicals, hazardous areas Configuration Technical specifications
| Compact (7ML701 and 7ML700) | Extended (7ML702 and 7ML703) |
|---|
Mode of Operation |
|
| Measuring principle | Capacitive level detection | Capacitive level detection | Input |
|
| Measured variable | Change in picoFarad (pF) | Change in picoFarad (pF) | Output |
|
| Output signal |
|
| | 8/16 mA or 4 ... 20 mA , 2-wire loop or
IO-Link, PNP, NPN | 8/16 mA or 4 ... 20 mA, 2-wire loop or IO-Link,
PNP, NPN *IO-Link not available with Cable version | | 4-wire relay (general purpose) or transistor
(intrinsically safe) | 4-wire relay (general purpose) or transistor
(intrinsically safe) | | Min. or max. | Min. or max. | Accuracy |
|
| Repeatability | 2 mm (0.08 inch) | 2 mm (0.08 inch) | Rated operating conditions1) |
|
| Installation conditions |
|
| | Indoor and outdoor | Indoor and outdoor | Ambient conditions |
|
| | ‑40 ... +85 °C (‑40 ... +185 °F) | ‑40 ... +85 °C (‑40 ... +185 °F) | | ‑40 ... +80 °C (‑40 ... +176 °F) | ‑40 ... +80 °C (‑40 ... +176 °F) | | I | I | | 4 | 4 | Medium conditions |
|
| - Relative dielectric constant εr
| Min. 1.5 | Min. 1.5 | - Process temperature – configuration dependent
| ‑40 ... +125 °C (‑40 ... +257 °F),
see temperature curve | ‑40 … +125 °C (‑40 ... +257 °F), see
temperature curve | - Pressure (vessel) – configuration dependent
| ‑1 ... 25 bar (363 psi) – Stainless Process
connection | ‑1 ... 25 bar (363 psi) - Rod extensions |
| ‑1 ... 10 bar (146 psi) – PPS process
connection | ‑1 ... 10 bar (146 psi) - Cable extensions | |
|
| | Type 4X/IP68 | Type 4X/IP68 | | Type 4X/IP68 | Not applicable | | ½" NPT or M20 x 1.5 | ½" NPT or M20 x 1.5 | Device version |
|
| Material |
|
| | Thermoplastic polyester | Thermoplastic polyester | | Transparent thermoplastic polycarbonate (PC) | Transparent thermoplastic polycarbonate (PC) | | 316L stainless steel | Not applicable | Sensor length (nominal) | 92 mm (3.6 inch) | 300 ... 4 000 mm (11.8 … 157 inch) -
Rod version 400 ... 20 000 mm
(15.7 ... 787 inch) - Cable version | Process connection material of probe/wetted parts2) | Connection: 316L stainless steel or PPS; Process seal: FKM (optional FFKM); Sensor: PEEK or PPS or PVDF | Connection: 316L stainless steel or PPS; Process seal: FKM (optional FFKM); Sensor: PPS or PVDF Extension: Pipe 316L Cable: FEP jacketed | Connection (Enclosure 65 mm) | Terminal block, terminals 0.14 ... 1.5 mm2 (AWG 28 ... 16) or M12 x 1 according
to IEC 61076-2-101, male, 4-pole, coding A-standard | Terminal block, terminals 0.14 ... 1.5 mm2 (AWG 28 ... 16) or M12 x 1 according to
IEC 61076-2-101, male, 4-pole, coding A-standard | Connection (Enclosure 35 mm) | M12 x 1 according to IEC 61076-2-101, male, 4-pole,
coding A-standard | Not applicable | Process connection | Thread: G ½", G ¾", G 1“, NPT ¾" Tri-clamp DN25 (1"), DN40 (1 1/2"), DN50 (2") DIN 32676 Type A (DIN 11851) and DIN 32676 Type C (ASME BPE 2009) Flange (screwed) DN 25, 40, 50; ASME 1", 1 ½”, 2" | Thread: G ¾", G 1“, NPT ¾" Flange: DN 25, 40, 50; ASME 1", 1 ½”, 2" Adapters for G 1 ½", NPT 1 ¼",
NPT 1 ½" | Power supply |
|
| Standard | - 4-wire with relay supply:
9 ... 33 V DC, 0.7W including 10 % of
EN 61010-1 - 2-wire with 8/16 or 4 ... 20 mA loop:
9 ... 33 V DC, 0.7W including 10 % of
EN 61010-1 - IO-Link / PNP / NPN
10 ... 30 V DC, incl. 10 % of
EN 61010-1
| - 4-wire with relay supply:
9 ... 33 V DC, 0.7W including 10 % of
EN 61010-1 - 2-wire with 8/16 or 4 ... 20 mA loop:
9 ... 33 V DC, 0.7W including 10 % of
EN 61010-1 - IO-Link / PNP / NPN
10 ... 30 V DC, incl. 10 % of
EN 61010-1
| Intrinsically Safe | - 2-wire with 8/16 or 4 ... 20 mA loop:
10.8 ... 30 V DC, 0.7W incl. 10 % of EN 61010-1, intrinsically safe barrier required - 4-wire with relay:
10.8 .... 30 V DC, 0.7W incl. 10 % of EN 61010-1, intrinsically safe barrier required
| - 2-wire with 8/16 or 4 ... 20 mA loop:
10.8 ... 30 V DC, 0.7W incl. 10 % of EN 61010-1, intrinsically safe barrier required
| Certificates and approvals | - General purpose: CE, UKCA, FM, CSA
- ATEX II 1G, 1/2G Ex ia IIC
- ATEX II 1D, 1/2D Ex ia IIIC
- IEC Ex ia IIC
- IEC Ex ia IIIC
- FM/CSA IS Class I, II, III, Div. 1,
Groups A ... G
- Overfill protection: WHG (Germany) VLAREM
| - General purpose: CE, UKCA, FM, CSA
- ATEX II 1G, 1/2G Ex ia IIC
- ATEX II 1D, 1/2D Ex ia IIIC
- IEC Ex ia IIC
- IEC Ex ia IIIC
- FM/CSA IS Class I, II, III, Div. 1,
Groups A ... G
- Overfill protection: WHG (Germany) VLAREM
|
Characteristic curves
|