Proline Promag P 200 electromagnetic flowmeter
|
Detailed Product Description
|
"Specs at a glance Max. measurement error Volume flow: ±0.5 % o.r. ± 2 mm/s (0.08 in/s) Measuring range 4 dm3/min to 1100 m3/h (1 to 4850 gal/min) Medium temperature range Liner material PFA: –20 to +150 °C (–4 to +302 °F) Liner material PTFE: –40 to +130 °C (–40 to +266 °F) Max. process pressure PN 40, Class 300, 20K Wetted materials Liner: PFA; PTFE Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022);
Tantalum; Platinum" "Field of application Promag P is dedicated to chemical and process applications with
corrosive liquids and high medium temperatures. With genuine
loop-powered technology, Promag P 200 enables cost-effective and
seamless integration into existing infrastructures. It offers
highest operational safety in hazardous areas thanks to its
intrinsically safe design (Ex ia). Heartbeat Technology enables
process safety at all times. The bidirectional measuring principle is virtually independent of
pressure, density, temperature and viscosity Dedicated to chemical and process applications with corrosive
liquids and high medium temperatures Device properties Nominal diameter: max. DN 200 (8"") All common Ex approvals Liner made of PTFE or PFA Loop-powered technology Robust two-chamber housing Plant safety: worldwide approvals (SIL, Haz. area)" "Benefits Versatile applications – wide variety of wetted materials Energy-saving flow measurement – no pressure loss due to
cross-section constriction Maintenance-free – no moving parts Convenient device wiring – separate connection compartment Safe operation – no need to open the device due to display with
touch control, background lighting Integrated verification – Heartbeat Technology" "Measuring
principle Electromagnetic Product headline The flowmeter for highest medium temperatures with genuine
loop-powered technology. Dedicated to chemical and process applications with corrosive
liquids and high medium temperatures. Sensor features Diverse applications – wide variety of wetted materials.
Energy‐saving flow measurement – no pressure loss due to cross
section constriction. Maintenance‐free – no moving parts. Nominal diameter: max. DN 200 (8""). All common Ex approvals. Liner
made of PTFE or PFA. Transmitter features Convenient device wiring – separate connection compartment. Safe
operation – no need to open the device due to display with touch
control, background lighting. Integrated verification – Heartbeat
Technology. Loop-powered technology. Robust dual-compartment housing. Plant
safety: worldwide approvals (SIL, Haz. area). Nominal diameter range DN 15 to 200 (½ to 8"") Wetted materials Liner: PFA; PTFE Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022);
Tantalum; Platinum Measured variables Volume flow, mass flow Max. measurement error Volume flow: ±0.5 % o.r. ± 2 mm/s (0.08 in/s) Measuring range 4 dm3/min to 1100 m3/h (1 to 4850 gal/min) Max. process pressure PN 40, Class 300, 20K Medium temperature range Liner material PFA: –20 to +150 °C (–4 to +302 °F) Liner material PTFE: –40 to +130 °C (–40 to +266 °F) Ambient temperature range Flange material carbon steel: –10 to +60 °C (+14 to +140 °F) Flange material stainless steel: –40 to +60 °C (–40 to +140 °F) Sensor housing material AlSi10Mg, coated Transmitter housing material AlSi10Mg, coated Degree of protection IP66/67, type 4X enclosure Display/Operation 4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available Outputs 4‐20 mA HART (passive) Pulse/frequency/switch output (passive) Inputs None Digital communication HART, PROFIBUS PA, FOUNDATION Fieldbus Power supply DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch
output) Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, JPN, UK Ex Other approvals and certificates Product safety CE, C-Tick Functional safety Functional safety according to IEC 61508, applicable in
safety-relevant applications in accordance with IEC 61511 Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to
ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement
traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV
SÜD attestation) Pressure approvals and certificates CRN, PED Material certificates 3.1 material Hygienic approvals and certificates Drinking water approvals: ACS, NSF 61" |
| Product Tags: Proline Promag P 200 flowmeter electromagnetic flow meter with warranty industrial electromagnetic flow meter |
Related Products
Email to this supplier