China Water Quality Sensor manufacturer
Xi'an Kacise Optronics Co.,Ltd.
Kacise, understanding your automation needs.
8
Home > Products > Electromagnetic Flow Meter >

Flow-X flow computer

Flow-X flow computer

Brand Name Endress+Hauser
Model Number Flow-X
Certification CE
Place of Origin Switzerland
Minimum Order Quantity 1PCS
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measuring variables gas volume conversion, event logging, parameter logging, and reports
Number of applications Support up to 4 gas runs or 2 liquid runs per module (Flow-X/M, Flow-X/C)
Electrical connection Voltage24 V DC (± 10%), with redundant connectionsCurrent consumption:Flow-X/P0, X/M, X/S: ≤ 0.4 A nominal; ≤ 0.8 A maximalFlow-X/C: ≤ 0.6 A nominal; ≤ 1.0 A maximal
Ambient temperature range Flow-X/S: -40 °C ... +75 °CFlow-X/C, Flow-X/P, Flow-X/R: 0 °C ... +60 °C
Detailed Product Description
 
Number of applications
Support up to 4 gas runs or 2 liquid runs per module (Flow-X/M, Flow-X/C)
 
Inputs
6x analog transmitter input, high accuracy
Input types are 4 to 20 mA, 0 to 20 mA, 0 to 5 V, 1 to 5 V
Accuracy mA inputs; 0.002% FS at 21 °C, 0.008% at full ambient range of 0-60 °C, long-term
stability 0.01% per year
Resolution: 24 bits. Analog inputs have the same earthing relative to all other electronic devices.
 
16x digital status inputs. Resolution 100ns (10MHz)
 
Outputs
4x analog output for process outputs and flow / pressure control. Resolution 14 bits, 0.075% FS.
Analog outputs share same ground floating in relation to all other electronics.
 
16x digital output, open collector. Rating 100mA @24V" "Field of application
The Flow-X flow computer provides gas volume conversion, event logging, parameter logging, and reports using state-of-the-art technology. Identical modules are combined in different housings, offering a multi-stream version Flow-X/P for 1 - 4 measuring distances with a local touch screen, or the version Flow-X/S for smaller installations with one measuring distance. It is the ideal partner for custody transfer gas metering solutions in installations with FLOWSIC600 ultrasonic gas flowmeters.
 
Custody gas metering
 
Demanding natural gas and process gas applications
 
 
Device properties:
 
MID approved configuration for gas metering streams with FLOWSIC600
 
Powerful modules for demanding applications
 
Each module features CPU, memory and equal in/outputs
 
Intuitive user interface for graphics display and web browser
 
True remote access via Ethernet
 
Station computer for multiple streams" "Benefits
Reduced planning and installation costs through standard configurations
 
Very accurate volume conversion with multiple calculation cycles per second
 
High reliability through independent modules with their own volume conversion and storage of measured values, counter readings and events
 
Easy extension of installations with modules featuring equal in/outputs and 100% software configuration
 
Reduced service and maintenance costs with tamper-proof remote maintenance
 
Cost-efficient and flexible system integration of multiple streams" "Measuring principle
flow computer
 
Measuring variables
gas volume conversion, event logging, parameter logging, and reports
 
Number of applications
Support up to 4 gas runs or 2 liquid runs per module (Flow-X/M, Flow-X/C)
 
Calculations
Gas property calculations:
AGA 5, AGA 8 Part 1, AGA 8 Part 2 (GERG-2008), AGA 10
AGA NX-19
GERG-2008
GERG91mod (GOST 30319.2-1996)
GOST 30319.2-2015
GSSSD MR-113
ISO 6976, ISO 12213 Parts 2 and 3
S-GERG
Flow rate calculations:
AGA 3, AGA 7, AGA 9, AGA 11
 
Electrical connection
Voltage
24 V DC (± 10%), with redundant connections
Current consumption:
Flow-X/P0, X/M, X/S: ≤ 0.4 A nominal; ≤ 0.8 A maximal
Flow-X/C: ≤ 0.6 A nominal; ≤ 1.0 A maximal
 
Ambient temperature range
Flow-X/S: -40 °C ... +75 °C
Flow-X/C, Flow-X/P, Flow-X/R: 0 °C ... +60 °C
 
System
CPU and memory: 800 MHz, 512 MB RAM, 1 GB flash memory
Clock: Real-time clock, accuracy better than 1 sec/day
Gold cap for date and time retention
Watchdog: Hardware and software watchdog timer
Tamper switch: Mechanical tamper switch to prevent changing of the application and vital parameters within
that application
 
Supported gas chromatographs
Supports all common gas chromatographs (including ABB NGC8200 series, ABB BTU8100,
Danalyser, Yamatake HGC, Encal 3000, Angus GQA, Siemens Maxum and Sitrans)
 
Conformities
2014/32/EU Measuring Instruments Directive (MID)
 
Directive 2014/30 / EC relating to electromagnetic compatibility
 
2012/19/EU WEEE Directive (WEEE 2)
 
2011/65/EU RoHS
 
OIML R117-1
 
WELMEC 7.2, 8.3, 8.8
 
API 21.1
 
Hazardous area approvals
Applies for FlowX/M and X/S only
Class I, Division 2, Groups A, B, C, and D, T4
Class I, Zone 2, Group IIC, T4
IECEx Ex ec IIC Gc
ATEX II 3 G Ex ec IIC Gc
 
Inputs
6x analog transmitter input, high accuracy
Input types are 4 to 20 mA, 0 to 20 mA, 0 to 5 V, 1 to 5 V
Accuracy mA inputs; 0.002% FS at 21 °C, 0.008% at full ambient range of 0-60 °C, long-term
stability 0.01% per year
Resolution: 24 bits. Analog inputs have the same earthing relative to all other electronic devices.
 
16x digital status inputs. Resolution 100ns (10MHz)
 
Outputs
4x analog output for process outputs and flow / pressure control. Resolution 14 bits, 0.075% FS.
Analog outputs share same ground floating in relation to all other electronics.
 
16x digital output, open collector. Rating 100mA @24V"
 
 
 
 
 
 
 
 
 
 
 
 
 