China Water Quality Sensor manufacturer
Xi'an Kacise Optronics Co.,Ltd.
Kacise, understanding your automation needs.
8
Home > Products > Ultrasonic Flow Meter >

FLOWSIC600-XT ultrasonic flowmeter

FLOWSIC600-XT ultrasonic flowmeter

Brand Name Endress+Hauser
Model Number FLOWSIC600-XT
Place of Origin Switzerland
Minimum Order Quantity 1PCS
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measuring principle Ultrasonic transit time difference measurement
Measured variables Volumetric flow a. c., volume a. c., gas velocity, Speed of sound, optional volume correction via integrated, electronic volume corrector (EVC)
Measuring Medium Natural gas (with up to 30% hydrogen), air, natural gases containing increased levels of CO2, N2, H2S, O2, H2
Repeatability ≤ 0.05 % of the measured value (typical)
Medium temperature range –46 °C ... +180 °C / -51 °F ... +356 °F
Operating pressure range 0 bar (g) ... 450 bar (g) 0 psi (g) ... 6527 psi (g)
Detailed Product Description
"Specs at a glance
Measured variables
Volumetric flow a. c., volume a. c., gas velocity, Speed of sound, optional volume correction via integrated, electronic volume corrector (EVC)
 
Measuring Medium
Natural gas (with up to 30% hydrogen), air, natural gases containing increased levels of CO2, N2, H2S, O2, H2
 
Nominal pipe size
3 ″ ... 56 ″
(DN 80 ... DN 1400), other nominal pipe sizes on request" "Field of application
FLOWSIC600-XT is available in variants with 4, 4+1, 4+4, and 8 measurement paths. In addition to the OIML R 137 Class 1.0 requirements, FLOWSIC600-XT meets the requirements of Class 0.5 and AGA9 in their entirety. FLOWSIC600-XT contains i-diagnostics™ – an intelligent application diagnostics function – and PowerIn Technology™ for continuous measurement operation for up to three weeks in the event of a mains voltage failure. For the very best possible measurement accuracy and long-term stability.
 
Custody transfer measurement of natural gas
 
Custody transfer measurement of natural gas with up to 30% H2
 
Transport and storage of gas
 
Onshore and offshore applications
 
 
Device properties:
 
Automatic adjustment of pressure and temperature influences
 
Available for all operating conditions
 
PowerIn Technology™ for reliable backup operation
 
Intelligent application diagnostics with i-diagnostics™
 
Measuring capability up to 30% hydrogen in natural gas" "Benefits
Low measurement uncertainty in every application
 
Excellent measurement data reliability and availability
 
The right ultrasonic gas flow measuring device for every application – without compromise
 
Simple device integration – even in compact systems
 
Quick and easy commissioning and checks
 
Economical quantification of the H2 content in natural gas" "Measuring principle
Ultrasonic transit time difference measurement
 
Measured variables
Volumetric flow a. c., volume a. c., gas velocity, Speed of sound, optional volume correction via integrated, electronic volume corrector (EVC)
 
Measuring Medium
Natural gas (with up to 30% hydrogen), air, natural gases containing increased levels of CO2, N2, H2S, O2, H2
 
Repeatability
≤ 0.05 % of the measured value (typical)
 
Accuracy
4-path and 8-path version ≤ ± 0.5 % | (≤ ± 1%) Dry-calibrated
 
4-path and 8-path version ≤ ± 0.2 % | (≤ ± 0.5%) After flow calibration and alignment using constant factor. Without the calibration uncertainty of the test bench.
 
4-path and 8-path version ≤ ± 0.1 % | (≤ ± 0.2%) After flow calibration and alignment using polynomial or piecewise correction. Without the calibration uncertainty of the test bench.
 
Medium temperature range
–46 °C ... +180 °C / -51 °F ... +356 °F
On request:–194 °C ... +280 °C / –381 °F ... +536 °F
 
Operating pressure range
0 bar (g) ... 450 bar (g) 0 psi (g) ... 6527 psi (g)
 
Nominal pipe size
3 ″ ... 56 ″
(DN 80 ... DN 1400), other nominal pipe sizes on request
 
Metrological approvals and certificates
OIML R 137-1&2:2012 (class 0.5)
OIML D 11:2013
ISO 17089-1
AGA-Report Nr. 9
MID: 2014/32/EU
PED: 2014/68/EU
ASME: B16.5, B16.47 A/B
ATEX: 2014/34/EU
EMC: 2014/30/EU
GOST 8.611-2013
GOST 8.733-2011
CPA: JJG1030-2007
PCEC: GB 3836.1-2010, GB 3836.2-2010, GB 3836.4-2010, GB/T 3836.22-2017
 
Hazardous area approvals
IECEx
Ex db ia op is [ia Ga] IIA/IIC T4 Gb
Ex db eb ia op is [ia Ga] IIA/IIC T4 Gb
Ex ia op is IIA/IIC T4 Ga
 
ATEX
II 2 (1) G Ex db ia op is [ia Ga] IIA/IIC T4 Gb
II 2 (1) G Ex db eb ia op is [ia Ga] IIA/IIC T4 Gb
II 1G Ex ia op is IIA/IIC T4 Ga
NEC/CEC (US/CA)
Explosion-proof / non-incendive:
CI I, Div. 1 Group D, T4 / Ex d ia [ia Ga] IIA T4 Gb / Cl I, Zone 1 AEx d ia op is [ia Ga] IIA T4 Gb
CI I, Div. 1 Groups B, C, D, T4 / Ex d ia [ia Ga] IIC T4 Gb / Cl I, Zone 1 AEx d ia op is [ia Ga] IICT4 Gb
Intrinsically safe:
CI I, Div. 1 Group D T4 / Ex ia IIA T4 Ga / Cl I, Zone 0, AEx ia op is IIA T4 Ga
CI I, Div. 1 Groups A, B, C, D, T4 / Ex ia IIC T4 Ga / Cl I, Zone 0, AEx ia op is IIC T4 Ga
 
Digital Outputs
4 outputs: 2 x status, 2 x pulse:
≤ 30 V, 50 mA
Passive, electrically isolated, open collector or conforming to NAMUR (DIN EN 60947-5-6), fmax = 10 kHz(scalable)
 
Digital communication
Modbus TCP"
Product Tags: FLOWSIC600-XT ultrasonic flow meter   industrial ultrasonic flowmeter   high-precision ultrasonic flow meter  