China Fluid Level Meter manufacturer
Xi'an Kacise Optronics Co.,Ltd.
Kacise, understanding your automation needs.
7
Home > Products > Ultrasonic Flow Meter >

KUFS2000B Panel Mount Insertion Ultrasonic Flow Meter Installed In Instrument Box

KUFS2000B Panel Mount Insertion Ultrasonic Flow Meter Installed In Instrument Box

Brand Name Kacise
Model Number KUFS2000B
Place of Origin China
Minimum Order Quantity 1
Price 274~316USD/pc
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 100+
Delivery Time 5-8 work days
Packaging Details carton
Accuracy ±1%
Velocity Range 0~±10m/s, Bi-directional measurement
Pipe Size DN50~DN6000
Temperature - 30~160℃
Power Supply DC8~36V or AC85~264V
Interface RS485, support MODBUS
Data Storage SD card regularly store the pre-set results (optional)
Detailed Product Description

KUF2000 Series Insertion Ultrasonic Flow Meter

Introduction
KUF2000 series insertion type ultrasonic flow meter consists of the meter and insertion transducer.
Install the transducer by opening two holes on the pipeline. No need to cutoff water by using the specialized tool. Transducers are in direct contact with fluid, which make the measurement more steady and reliable.
If connecting Pt100 temperature transducer, it can realize the heat/energy measurement.

 

The KUFS2000B flow meter can be installed in instrument box.
Optional insertion type transducers, measuring range from DN50~DN6000mm.

 

Working Condition

 Main UnitSensor
ProtectionNoneIP68
Humidity≤80%RH
Temperature-20~60℃-30~160℃

 

Basic Parameters

Accuracy±1%
Velocity Range0~±10m/s, Bi-directional measurement
Pipe SizeDN50~DN6000
Temperature- 30~160℃
Type of LiquidSingle liquid can transmit sound wave. such as water, sea water, sewage, oil, chemicals , alcohol, etc
Pipe Material

Carbon steel, stainless steel 304, stainless steel 316.

Flange standard GB/T9119-2000, GB/T81-94

Signal Output

1 way 4-20mA output(impedance 0~1K, accuracy 0.1%)

1 way OCT pulse output( Pulse width 6 ~ 1000ms)

1 way relay output

Signal Input3 way 4-20mA input, achieve to heat measurement by connecting PT100 platinum resistor.
InterfaceRS485, support MODBUS
Data StorageSD card regularly store the pre-set results (optional)
Power SupplyDC8~36V or AC85~264V

 

Optional Insertion Sensors

Standard Insertion Sensor

· Suitable for the pipeline can be directly welded, like carbon steel and stainless.

· Pipeline thickness ≤ 2 0

· Measuring range: DN50~DN6000

· Temperature range:-30~+160℃

Extended Insertion Sensor

· Suitable for the pipeline cannot be directly welded, like cement pipe, cast iron, PVC, steel or composite material.

· Pipeline thickness ≤ 7 0

· Measuring range: DN50~DN6000

· Temperature range:-30~+160℃

 

Parallel Insertion Sensor

· Suitable for installation of insufficient space.

· Suitable for either weldable or non-weldable pipeline.

· Unlimited pipeline thickness, insertion depth=1/3 inner diameter.

· Measuring range: DN80~DN6000

· Temperature range: -30~+160℃

 

Pipe Clamp
By using pipe clamp, the insertion sensor can be installed without welding. There is no need to cut off water during installation. Especially suitable for cement pipe, cast iron pipe, PVC, copper pipe or composite material.

 

Ordering information

 

 

 

Product Tags: Panel Mount Insertion Ultrasonic Flow Meter   KUFS2000B Ultrasonic Flow Meter   DN50 Ultrasonic Flow Sensor  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Xi'an Kacise Optronics Co.,Ltd.
Subject:
Message:
Characters Remaining: (80/3000)