More tha 30 color indicators, including pt-co, Gardner, Saybolt,
China, the United States, European pharmacopoeiastandardsIntelligent zero calibration ensures accurate measurement of
△E*ab≤0.01The minimum liquid addition is reduced to 1ml, 10mm and 50mm
cuvette are standard, and 33mm and 100nm cuvette are optionalFast measurement, and a single measurement takes only 1.5 secondsThe thermostatic sample tank(upto90°C) design ensures sample
fluidityThe 7-inch touch screen make the instrument more user friendly and
the instrument can store more than 100,000 pieces of data 一,Product characteristics - Ultra-wide wavelength range 360-780nm
- More than 30 chroma indicators
- Intelligent zero calibration technology is used to ensure data
stability of 0.01
- Minimum sample request reduced to 1ml
- The PTC heating module produces a constant temperature of up to
90°C
- Support OTA online upgrade to update chroma indicators and new
functions atanytime
- 7 inch touch screen operation, clear display of measurement
data
二,Technical parameterProduct model | DS-810N | DS-812N | DS-816N | Measurement condition | d/0(,0)(:CIE No.15,ISO 7724/1,ASTM E1164,DIN 5033 Teil7,JIS Z8722
Condition c,GB/T 3555,ASTM D156,GB/T 6540,ASTM D1500,ASTM
D1209,ASTM D5386,ASTM D6045,ASTM D6166,ASTM D1502) | Stand-alone operation | Support | Integrating sphere | Φ40mm,Avian-D Fully diffuse surface coating | Lighting source | CLEDs(Full band balanced Led light source) | Inductor | Dual optical sensor array sensor | Wavelength range | 360-780nm | Wavelength interval | 10nm | Half-band width | 5nm | Measuring range | 0~200% | Resolution | 0.0001 | Observer Angle | 2°/10° | Observation light source | A,B,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,U35,DLF,NBF,TL83,TL84,ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V4 | Display | Pharmacopoeia color number, transmission map/data, sample
chromaticity value, color difference value/map, pass/fail result,
color deviation, color simulation, historical data color
simulation, manual input of standard sample, test report | Measuring time | ≤1.5s | Measuring optical path | Standard: 10mm glass cuvette, 50mm glass cuvette (optional 33mm and
100mm glass cuvette) | Color space | CIE Lab,LCh,CIE Luv,XYZ,Yxy,Transmissivity, Hunter Lab
Munsell,MI,CMYK | Other indicators | Pharmacopoeia (Chinese Pharmacopoeia, European Pharmacopoeia,
American Pharmacopoeia),WI(ASTM E313-20,ASTM
E313-73,CIE,ISO2470/R457,Hunter,Taube Berger Stensby),YI(ASTM
D1925,ASTM E313-20,ASTM E313-73),Tint(ASTM E313-20),Allochromic
index Milm,APHA,Hazen,Pt-Co(Platinum-cobalt index),Gardner(Gardner
index),Iron cobalt index,Saybolt(Seibert index),ASTM Color,EBC(Beer
color),ICUMSA Color(Sugar chroma) | Repeatability | Transmittance: standard deviation ≤0.08% Colorimetric value: ΔE*ab≤0.015 standard deviation, maximum ≤0.04 | Transmittance: standard deviation ≤0.08% Colorimetric value: ΔE*ab≤0.01 standard deviation, maximum ≤0.03 | Color difference formula | ΔE*ab < 0.25 | ΔE*ab < 0.25 | ΔE*ab < 0.25 | Heating function | / | Heating temperature range | / |
|