Sulfur Dioxide Test Chamber Cylinder Method
|
DX7130 Sulfur dioxide test chamber
Reference standard: GB/T9789-2008 sulfur dioxide corrosion test for metal and other non-metallic organic overlays under normal condensation conditions Random information: certificate, warranty card, circuit diagram Manual: operation method, precautions, basic parts for shipment, maintenance matters
Safety protection device: Test chamber: over-temperature protection, overall equipment timing Others: leakage protection, short circuit protection, water shortage alarm
Sulfur dioxide concentration control: The gas concentration is controlled by a metering buoy The air duct is connected by corrosion-resistant silicone tubing The waste disposal machine adopts a centrifugal plastic fan The exhaust gas is filtered with activated carbon and soda ash and then discharged outdoors by an exhaust fan
Heating system: Heating structure: far-infrared nickel-chromium alloy high-speed heating electric heater, high temperature completely independent system, temperature control output power is calculated by microcomputer, in order to achieve high precision and high efficiency power efficiency
STUDIO SIZE: 600*550*900MM DIMENSIONS: 1050*1180*1510MM
Controller Smart XMT7512D series Membrane KEY BOARD buttons Touch-sensitive settings, digital and direct display Displays resolution Temperature: 0.1°C (display range) Time: 0.1min Temperature sensor: PT100 platinum resistance thermometer Control mode: thermal balance temperature and humidity control; Temperature and humidity control adopts P.I.D+S.S.R system channel coordinated control; With the function of automatic calculation, the temperature and humidity change conditions can be corrected immediately, so that the temperature control is more accurate and stable Others: The core components are imported (Schneider) components to better control the temperature
Technical indicators of gas corrosion chamber: 1.1. Temperature range: RT+10°C~50°C 1.2. Humidity range: >95%RH (actual humidity in the studio) 1.3. Temperature uniformity: ≤2°C 1.4. Temperature fluctuation: ±0.5°C 1.5. Gas generation method: cylinder method 1.6. Sulfur oxide gas concentration: 0.1~1.0% (volume percentage)
Installation site: The floor is flat and well ventilated There are no strong vibrations around the device There is no strong electromagnetic field around the device There are no flammable, explosive, corrosive substances and dust around the equipment Installation requirements There is appropriate space for use and maintenance around the equipment, as shown in the figure: A: Not less than 60cm B: not less than 60cm C: Not less than 120cm (Note: (The tilt angle of the device cannot exceed 15°C))
Environmental conditions: Temperature: 5°C~+28°C (average temperature within 24 hours≤28°C) Relative humidity: ≤85%RH Air pressure: 86kPa~106kPa Power supply conditions: Voltage range: AC (220±10%)V Allowable frequency fluctuation range: (50±0.5)Hz single three-wire system The user is required to configure the equipment with an air or power switch of the appropriate capacity at the installation site, and this switch must be used independently for this equipment When the equipment is not working, the temperature of the environment should be kept within 0°C~+45°C The net weight of the equipment is 130KG
Material Structure: Shell material: high-quality PP reinforced rigid plastic sheet, smooth and smooth surface, high strength, anti-aging and corrosion-resistant Liner material: high-quality PP reinforced rigid plastic sheet, smooth and smooth surface, high strength, anti-aging and corrosion-resistant Door material: fully transparent high-temperature resistant high-quality tempered glass, which is convenient for observing the test condition of the test sample during the test Temperature circulation system: special air-conditioning type low-noise long-axis fan motor, high and low temperature resistant stainless steel multi-wing impeller, to achieve strong convection vertical diffusion circulation Auxiliary structure: the lid and the box body are sealed with silicone rubber to prevent gas overflow; The heating is the inner tank type heating method, which heats up quickly and the temperature distribution is uniform Standard configuration: 2nd floor of sample holder
Atmospheric appearance, easy maintenance, scientific design The sulfur dioxide test chamber can also test the corrosion resistance of some products by assessing the corrosion ability of the material and its protective layer, as well as the process quality comparison of similar protective layers.
Double-layer gas filtration device, zero pollution, more environmentally friendly The exhaust fan adopts a centrifugal plastic fan The exhaust gas is filtered by activated carbon and soda ash, and then discharged outdoors by an exhaust fan
Exquisite, unique, corrosion-resistant, clear and clear The whole is imported PVC reinforced hard plastic plate, with a smooth and smooth surface, and resistant to aging and corrosion; Easy to clean, no leakage, abandon the FRP material should produce surface fading fibrosis over time, fully transparent imported impact-resistant plate manufacturing, convenient for observing the test sample test condition during the test. |
Product Tags: Cylinder Method Test Chamber Sulfur Dioxide Test Chamber |
![]() |
Low Temperature Constant Temperature Water Tank Heating Refrigeration Reactor |
![]() |
Sulfur Dioxide Test Chamber Cylinder Method |
![]() |
DX8217 FAA FAR 25.853 Vertical Flammability Chamber Stainless Steel Adjustable |
![]() |
DX8332B Roadway Propane Combustion Performance Tester |
![]() |
Soft Furniture Spring Soft Mattress And Sofa Anti Ignition Characteristics Testing Machine |
![]() |
Low Temperature Constant Temperature Water Tank, Heating Refrigeration Reactor |