Power Supply | Single-phase AC 220V / 50Hz |
Air Supply | 0.6 MPa |
Control System | PLC + Industrial PC |
Barcode Scanning | The device comes with a scanner to read barcodes or QR codes on the test samples. Scan the product before testing; after the test, the scanned code is automatically associated with the test record, enabling traceability. |
Wire Continuity Tests | Break, continuity, short circuit, and wiring sequence tests are
performed via PLC Input/Output scanning. PLC automatically determines pass/fail. |
Built-in Resistance Range | 1 – 5000 Ω, Accuracy: 1% Upper and lower limits can be set to determine product quality. |
CC & PE Resistance (Button Pressed / Not Pressed) | 16A AC plug: Not Pressed RC: 680Ω,Pressed RC+R4:3.38 kΩ 32A AC plug:Not Pressed RC: 220Ω,Pressed RC+R4:3.52 kΩ 63A AC plug:Not Pressed RC: 100Ω,Pressed RC+R4:3.4 kΩ The measurement accuracy of the resistance must reach 1%–2%. |
Thermistor Testing Range | 100 – 50,000 Ω, Accuracy: 2% |
| Upper and lower limits can be set to determine continuity quality. |
Current Carrying Capacity & Voltage Drop Test | Measures voltage drop across connectors under rated and overload current conditions. Built-in three-phase adjustable transformer: 0-380V output, adjustable three-phase load 0-35A. Supported test ranges: 3.3 kW 16A single-phase 7.4 kW 32A single-phase 11 kW 16A three-phase 22 kW 32A three-phase |
Insulation Resistance Test | Single-phase: L-N, L-E, E-N Three-phase:L1/L2/L3/E-N, L1/L2/L3/N-E, N/L2/L3/E-L1, L1/N/L3/E-L2, L1/L2/N/E-L3 Parameters: >1. >Test voltage: DC 100 – 1000V (adjustable) >2. >Lower limit: 1 M–1 GΩ (adjustable) >3. >Accuracy: ±5% >4. >Alarm when resistance < set value |
Dielectric Withstand (Hi-Pot) Test | Single-phase: L-N, L-E, E-N Three-phase: L1/L2/L3/E-N, L1/L2/L3/N-E, N/L2/L3/E-L1,
L1/N/L3/E-L2, L1/L2/N/E-L3 Parameters: >1. >Test voltage: AC 0 – 5 kV / DC 0 – 6 kV (adjustable) >2. >Leakage current limit: AC 0.1 – 20 mA, DC 0.01 – 5 mA >3. >Accuracy: ±1.5% + 3 digits >4. >Digital display of voltage, automatic programmable adjustment >5. >Alarm if leakage current exceeds set value |
Test Station | Single station, one product per test |
Plug Holders | EU AC vehicle plug holder, EU AC pedestal plug holder, GB AC plug holder, US AC plug holder |
Tail Plate | Special pressing fixture matching the test product, with clamp and protective plate |
Socket Height | 750 – 1000 mm, ergonomically designed |
Computer Software | >1. >Supports Win 7 and Win 10, All parameter settings can be configured
through the software. >2. >Each product’ s test results are saved to the computer in real time for easy access, viewing, and analysis. >3. >Communication interfaces are reserved for optional connection to MES systems, allowing test data to be uploaded to the MES database
for management and control. >4. >Test data is stored immediately after completion. |
| 5. Stored test data can be exported in TXT or Excel format. |
Dimensions | W 900 × D 800 × H 1800 mm |
Weight | approx. 300 kg |
Others | >1. >Mobile casters with locking function. >2. >MES Connectivity: Optional, additional cost applies. |