UL94 Horizontal And Vertical Burning Test Apparatus 50W 500W Double
Power Switching
Product Information:
Standard: IEC60695-11-10, IEC60695-11-20, UL94, IEC60695-11-2,
IEC60695-11-3, IEC60695-11-4.
Application:It is required by IEC 62368-1:2018 Annex S, IEC
60950:2013 clause 4.7.3, IEC60065:2014 clause 14.1, 20.2.1, 20.2.4,
Annex G, IEC60335-1 clause 30, etc. It simulates the influence of
early-stage flame when there is a fire around the electric and
electronic products, so that to judge the igniting danger degree.
It is mainly used in plastic and other non-metallic material
sample, solid material. It is also applicable in the Horizontal,
vertical flammability test of the relative combustion
characteristic of foam plastics whose density is no-less than
250kg/m according to ISO845 test method.
Test sample:It is also applicable in the Horizontal, vertical
flammability test of the relative combustion characteristic of foam
plastics whose density is no-less than 250kg/m according to ISO845
test method.
Feature: This series of products adopt integral type inlet ignition
system. The combustion time delays 0.1S thus to make sure the
sufficient time of gas burning. They are with matte black
background, multi-functional flame measure gauge, stainless steel
of box full, large observation window, imported digital indicator
of high precision, nice appearance. And they gather a number of
advantages of similar products home and abroad.
Technical Parameters:
Working voltage | 220V/50Hz | Power/grade | 50W and 500W double power switching | Control operation mode | PLC control, 7-inch color touch screen operation, with infrared
remote controller | Blast burner standard | IEC60695-11-10/IEC60695-11-20, UL94, etc. inner diameter:Φ9.5±0.3mm,length:100mm,made of brass | Gas pressure | 0.1MPa | Gas flow | 50W:105±5ml/min or 18±1mm;500W:965±30ml/min or 117±3 mm,flow meter
adjustment | U type pressure gauge back pressure water column height | 50W:10mm; 500W:125±5 mm | Test angle | 50W: 0°,45°; 500W: 20° | Burning time | 0-9999X0.1S Can be preset | Burning times | 0-9999 times,Can be preset | Residual flame/Residual glow | 0-9999X0.1S Can be displayed | Test flame calibration | Temperature measuring copper head:50W:Ф5.5mm±0.01mm,weight before
drilling 1.76 ± 0 .01 g;500W:Ф9mm±0.01mm,weight before drilling 10
± 0 .05g | Thermocouple: The American original Omega φ0.5 armour
nickel-chromium/nickel aluminum wire K-Thermocouple, temperature
resistance 1100° | Distance between the bunsen burner port to temperature measuring
copper block:50W: 10±1 mm; 500W: 55±1 mm | Flame height:50W: 20±2mm(there is no internal and external flame);
500W: Inner flame:40±2mm,Outer flame:125±10mm | Temperature rise time from100±2°to 700°±3°50W: 44±2S; 500W: 54±2S | Lighting | Equip with lighting in the test chamber, with control | Test chamber and dimension | > 0.75 cube, black inwall, with exhaust fan,
dimension:1100*550*1200mm, 140kg |
|