Samples and restrictions | Edison lamp cap |
Test purpose | Used to detect the mechanical strength of caps of Edsion lamps. |
Test principle | Use a motor-driven pressure plate to apply a certain pressure to
the center of the lamp cap, so that the test lamp cap exerts force
vertically along the axis of the fluorescent lamp until the force
reaches a constant value for 1 minute and then released.
|
Structure and features | Single-arm force applying mechanism, force value can be set, LCD
screen operation and display |
Power supply | AC220V,50Hz |
Main performance indicators |
Test station | Single station |
Electrical control method | LCD interface operation and display, with force value curve |
Drive mode | Motor driven |
Specimen clamping method | Mechanical clamping, the clamping point position is adjustable
|
Force apply range | 0-500N, resolution 0.1N, accuracy 1%F.S. It can achieve achieve 80N
and 120N required by IEC62560:2015. |
Test gauge | 7006-6-1,7006-27H-1,7006-27F-1,7006-27B-1,7006-27-7, each one piece Accordingly following table:
|
force application speed | 0-300mm/min |
Stroke | 0-500mm,resolution: 0.01mm |
Result display | With force value-time curve, the test results can be output through
a micro printer |