IEC60598 Lamps And Lanterns Of High And Low Temperature Durability
Test Chamber Product overview: This test chamber conforms to IEC 60598-1: 2014 clause 12.3 and
etc. Specimen Limitation: Flammable, explosive, volatile substances Corrosive substances Biological specimens Electromagnetic emission source Technical Parameters: Name | Lamps and lanterns of high and low temperature durability test
chamber | Nominal volume | 864L | Power capacity | 8.5kW | Internal dimensions | W3000xD2400xH2500 mm | External dimensions | W3200xD2600xH2600 mm | Test environment conditions | Ambient temperature to 5 ~ 35 ℃, humidity ≤ 85% RH | Temperature range | RT+10 ℃ ~+70℃ (Low temperature models can be customized:For
example, it is lower than normal temperature) | Temperature fluctuations | ≤ ±1℃ Temperature accuracy (in time) | Temperature deviation | ≤ ±2.0℃Temperature uniformity (at steady state) | Gradient down | +70° ~RT℃ 1~2℃/min (Low temperature models exclusive) | Gradient up | RT℃~+70° 1~3℃/min | Aging rack | Aging rack structure: 6 shelves structure, 2 racks, size (length,
width, height) about: W1660XD730XH1780mm is divided into 6 layers,
the bottom layer is equipped with 5*4=20 E14 lamp holders, the
second layer is equipped with 5*4=20 E27 lamp holders, the middle
two layers are installed with 600-length LED bulbs dedicated (20
stations in each layer), the top two layers are installed with
1200mm length LED bulbs dedicated (10 stations in each layer), The
second layer of each rack is the wiring summary position, which
leads to the industrial circuit breaker and connects with the
socket introduced by the power control cabinet. All wires, cables
and terminals are made of high temperature and humidity resistant
materials, and all bulb wiring is made of high temperature wire. |
Structure: Insulating envelope | Room material: the room is made of rock wool galvanized steel
sandwich board, used for high temperature aging of electronic
products, beautiful appearance. Thermal insulation material: high
quality rock wool (75mm thick) | Air conditioning channel | Chamber body parts, air circulation, refrigeration (Optional),
heating system, electrical control part. | Test chamber standard configuration | One power cord (2 meters) (also can be adjusted according to
customer's site condition); One overtemperature protection; One cable hole (Φ50) (the left on equipment, equipped with
stainless steel cover). | Door | Single door, double door size would be 900cm*2000cm (W*H) | Control panel | Temperature (humidity) control display, over-temperature protection
setting device, lighting, switch, power switch | Distribution control cabinet | Cooling fan, the power distribution board, total power leakage
circuit breaker. | Air supply circulation system | Adopt high-quality air duct circulation unit to achieve forced
convection vertical diffusion circulation. The air circulation adopts the design of upper air outlet and lower
air return. The wind speed and air pressure meet the test
standards, and the temperature stabilization time is fast at the
moment of opening and closing the door. Optimized ventilation design, strong air supply and circulation,
avoid any dead angle, and make the temperature distribution in the
room uniform. More energy-saving, in line with current international and domestic
environmental protection requirements. Quieter, better to ensure a good office environment and the working
environment of operators. The extremely small tube volume and ultra-small volume ensure that
the room is bright, quiet, generous and beautiful. Easy installation, maintenance and repair. High quality and reasonable design. | Heater | Using high-efficiency nickel-chromium heating wire The heating system adopts the hot air circulation heating method,
the temperature distribution is uniform, the system is completely
independent, and the control circuit is not affected. The output power of temperature control is calculated by
microcomputer, and the heating power is automatically controlled
according to the size of the internal load, so as to achieve
high-precision and high-efficiency power consumption benefits, and
is more environmentally friendly and energy-saving. |
Refrigeration system (Optional, cost is additional) Work performance | More energy saving, in line with the current international and
domestic environmental requirements. | Refrigeration compressor | Quieter, better to ensure a good office environment and operating
staff working environment. | Evaporator | Extremely small volume of tube and super small volume, to ensure
that the room is bright and quiet, generous, beautiful. | Condenser | Easy to install, maintain and repair. | Throttling device | High quality and reasonable design. | Refrigerator control | All components have high reliability. | Refrigerant | Environmental refrigerant R404A (Ozone depletion index is 0) |
Electrical control system Controller | E600 Intelligent LCD touch screen PLC | Monitor | 5.7 Inch 640X480 lattice TFT color LCD monitor | Operation mode | The product adopts a resistive high-precision touch screen
operation mode, and you can directly use a USB mouse or a touch pen
to click on the screen to select functions or set parameters. | The programmable function has a capacity of 160Patten×1600 step×999
cycle. | Screen display function: LCD display, which can display test
conditions (including temperature segment, cycle times, running
time and remaining time, etc.). | With program control and fixed value control functions, it is
convenient for the use of various production conditions. | The setting of the temperature slope can freely control the running
time and the heating rate. | Reservation start function, after the system time reaches the set
time, the system will run automatically, which can freely control
the running time and working conditions of the aging room. | Power-off restart function, you can select cold start/warm
start/interruption for operation. | The temperature control adopts P.I.D.+S.S.R. system synchronous and
coordinated control, which can improve the stability and life of
control components and interfaces. | Real-time curve and historical curve query, which is convenient for
users to observe temperature changes in real time. | History dump function. With two USB interfaces, it is convenient
for users to save historical data. | File backup function. | The external computer connection interface can be connected to the
computer for remote operation. It has the functions of saving and
printing curves and experimental data. | Running the cumulative function, it is convenient for customers to
check the use status of the product for corresponding maintenance
and maintenance. | Screen saver function, better prolong the life of the LCD screen. | When the system is faulty, it can display fault information, fault
causes and solutions. | It has the function of permission level setting to avoid user mis
operation. | The function of switching between Chinese and English is convenient
for users of different languages to operate. | Control mode: PID (proportional-integral-derivative) automatic
calculation, PID control is simple and easy to understand, and does
not require an accurate system model and other prerequisites in
use. | In the setting, if an error occurs, a warning signal will be
provided. | The on-off function can save costs for designers and increase the
convenience of use. | Exhaust system | One set of exhaust system. Satisfy the temperature balance when the test product itself
generates too much heat in the aging room. When the aging room is overheated, the exhaust system is turned on,
so as to achieve the effect of balancing the indoor temperature. After the aging is over, the exhaust air is turned on. The exhaust duct is galvanized steel pipe, and the discharge
position is the position specified by the customer |
Safety protection device: Refrigeration system (Optional) | Compressor pressure The compressor motor over-heat The compressor motor over-current | Laboratory | Adjustable overtemperature protection | Others | Total power supply phase sequence and phase protection Earth leakage protection Load short-circuit protection |
|