| No.: | Category | Name | Standard Figure |
| 1 | E14 Lamp Cap | E14 Lam Cap “Go” Gauge | 7006-27F-1 |
| 2 | E14 Lamp Cap “Not Go” Gauge | 7006-28B-1 |
| 3 | E14 Lamp Cap Prevent Accidental Contact Gauge | 7006-55-2 |
| 4 | E14S1 Lamp Cap “Go” Gauge | 7006-27G-1 |
| 5 | E14 Lamp Cap Contacting Making Gauge | 7006-54-2 |
| 6 | E14 Lamp Cap Torque Test Gauge | IEC60968Fig2 |
| 7 | E27 Lamp Cap | E27 Lam Cap “Go” Gauge | 7006-27B-1 |
| 8 | E27 Lamp Cap“Not Go” Gauge | 7006-28A-1 |
| 9 | E27S1 Lamp Cap “Go” Gauge | 7006-27C-1 |
| 10 | E27 Lamp Cap Contacting Making Gauge | 7006-50-1 |
| 11 | E27 Lamp Cap Prevent Accidental Contact Gauge | 7006-51A-2 |
| 12 | E27 Lamp Cap Prevent accidental contact gauge 51*39 | 7006-51-2 |
| 13 | E27 Lamp Cap Torque Test Gauge | IEC60968Fig2 |
| 14 | B15 Lamp Cap | B15 Lamp Cap Insertion Gauge | 7006-4A-2 |
| 15 | B15 Lamp Cap Retention Gauge | 7006-4B-1 |
| 16 | B15 Lamp Cap “Not Go” Gauge | 7006-10-8 |
| 17 | B15 Lamp Cap “Go” Gauge | 7006-11-8 |
| 18 | B15 Lamp Cap Torque Test Gauge | IEC60968Fig3 |
| 19 | B22d Lamp Cap | B22 Lamp Cap Insertion Gauge | 7006-4A-2 |
| 20 | B22 Lamp Cap Retention Gauge | 7006-4B-1 |
| 23 | B22 Lamp Cap “Go” Gauge | 7006-10-8 |
| 24 | B22 Lamp Cap “Not Go” Gauge | 7006-11-8 |
| 25 | B22D Lamp Cap Acceptance Gauge | 7006-3-1 |
| 26 | BY22d Lamp Cap “Go” Gauge | 7006-17A-1 |
| 27 | B22 Lamp Cap Torque Test Gauge | IEC60968Fig3 |
| 28 | GZ10 Lamp Cap | “Go” / “Not Go” Gauge | 7006-120-1 |
| 29 | GZ10 Lamp Holder | “Go” / “Not Go” Gauge | 7006-120A-1 |
| 30 | GU10 Lamp Holder | “Go” / “Not Go” Gauge | 7006-121A-1 |
| 31 | GU10 Lamp Cap | GU10 Lamp Cap “Go” / “Not Go” Gauge | 7006-121-1 |
| 32 | E26 Lamp Cap | E26 Lamp Cap “Go” Gauge | 7006-27D-3 |
| 33 | E26 Lamp Cap “Not Go” Gauge | 7006-29L-4 |
| 34 | E26d Lamp Cap Prevent Accidental Contact Gauge | 7006-29A-2 |
| 35 | E26 Lamp Cap Contacting Making Gauge | 7006-29-3 |
| 36 | E26d Lamp Cap Reference Diameter 23mm “Go” Gauge | 7006-29B-2 |
| 37 | E26d Lamp Cap Reference Diameter 13.2mm “Go” Gauge | 7006-29C-2 |
| 38 | E26d Lamp Cap Reference Diameter 10.4mm “Go” Gauge | 7006-29D-1 |
| 39 | E26 Lamp Cap | | 7006-27E-1 |
| 40 | E14 Lamp Holder | “Go” Gauge | 7006-25-7 |
| 41 | “Not Go” Gauge | 7006-26-4 |
| 42 | Contacting Making Gauge | 7006-30-2 |
| 43 | Candle Lamp Contacting Making Gauge | 7006-30A-1 |
| 43 | Prevent Accidental Contact Gauge | 7006-31-4 |
| 44 | Torque Test Cap | IEC 60238 Figure5 |
| 45 | Test Cap "A" | IEC 60238 Figure13 |
| 46 | Test Cap "b" | IEC 60238 Figure13 |
| 47 | E27 Lamp Holder | “Go” Gauge | 7006-25A-2 |
| 48 | “Not Go” Gauge | 7006-26-4 |
| 49 | Prevent Accidental Contact Gauge | 7006-22A-4 |
| 50 | Anti-bulb Neck Damage and Contacting Making Gauge | 7006-21-5 |
| 51 | Inside Shrapnel Resilience Gauge | 7006-22D-1 |
| 52 | Side Contacts Edge Gauge | 7006-22B-1 |
| 53 | Side Contacts Resilience Gauge | 7006-22C-1 |
| 54 | Torque Test Cap | IEC 60238 Figure5 |
| 55 | Aging test cap | IEC 60238 Figure14 |
| 56 | E40 Lamp Cap | “Go” Gauge | 7006-27-7 |
| 57 | “Not Go” Gauge | 7006-28D-1 |
| 58 | Prevent Accidental Contact Gauge | 7006-53-1 |
| 59 | Contacting Making Gauge | 7006-52-1 |
| 60 | B22 Lamp Holder | Plug Gauge | 7006-12-8 |
| 61 | Gauge for checking contact position and contact force in (90°-130°) | 7006-15-7 |
| 62 | Gauge for checking contact position and contact force(90°-130°) | 7006-20-4 |
| 63 | Supplementary “Go” Gauge | 7006-12A-2 |
| 64 | “Not Go”/ Retention Gauge | 7006-12B-2 |
| 65 | Gauge for checking contact position and contact force | 7006-15A-2 |
| 66 | Gauge for the slots in lampholders | 7006-13-5 |
| 67 | Plug Gauge | 7006-17B-1 |
| 68 | E12 Lamp Cap | “Go” Gauge | 7006-27H-1 |
| 69 | “Not Go” Gauge | 7006-28C-1 |
| 70 | Supplementary “Go” Gauge | 7006-27J-1 |
| 71 | Contacting Making Gauge | 7006-32-1 |
| 72 | E17 Lamp Cap | “Go” Gauge | 7006-27K-1 |
| 73 | “Not Go” Gauge | 7006-28F-1 |
| 74 | Contacting Making Gauge | 7006-26D-1 |
| 75 | E39 Lamp Cap | “Go” Gauge | 7006-24B-1 |
| 76 | “Not Go” Gauge | 7006-24C-1 |
| 77 | Contacting Making Gauge | 7006-24A-1 |
| 78 | E40 Lamp Holder | “Go” Gauge | 7006-25-7 |
| 79 | “Not Go” Gauge | 7006-26-4 |
| 80 | Prevent Accidental Contact Gauge | 7006-24-3 |
| 81 | Contacting Making Gauge | 7006-23-3 |
| 82 | 1EP10 Lamp Cap | “Not Go” Gauge | 7006-28-7 |
| 83 | 2EP10 Lamp Cap | “Go” Gauge | 7006-37-1 |
| 84 | 3EY10 Lamp Cap | “Go” Gauge | 7006-7-1 |
| 85 | 4E10 Lamp Cap | “Go” Gauge | 7006-27A-2 |
| 86 | G5 Lamp Cap | “Go” and “Not Go” Gauge for Unfinished Bi-pin Cap | 7006-46-3 |
| 87 | “Go” Gauge for Bi-pin Cap on Finished Lamps | 7006-46A-3 |
| 88 | G13 Lamp Cap | “Go” and “Not Go” Gauge for Unfinished Bi-pin Cap | 7006-44-4 |
| 89 | “Go” Gauge for Bi-pin Cap on Finished Lamps | 7006-45-4 |
| 90 | G5 Lamp Holder | Contacting Making Plug Gauge for Finished Lamps | 7006-47A-2 |
| 91 | Double Ended Gauge | 7006-47B-3 III IV V |
| 92 | Double Ended “Go” Gauge | 7006-47B-3 I II |
| 93 | G13 Lamp Holder | Double Ended Gauge | 7006-60B-4 III IV V |
| 94 | Double Ended “Go” Gauge | 7006-60C-3 I II |
| 95 | GU5.3 Lamp Holder | “Go” Gauge | 7006-73A-1 |
| 96 | Gauge A | 7006-73A-2 |
| 97 | Gauge B | 7006-126B-1 |
| 98 | G9 Lamp Cap | “Go” Gauge | 7006-129-1 |
| 99 | “Not Go” Gauge | 7006-129A-1 |
| 100 | G5.3 Lamp Cap | Gauge for Bi-pin Cap G5.3 on Finished Lamps | 7006-73-1 |
| 101 | GU5.3 | “Go” and “Not Go” Gauge for Bi-pin Base | 7006-109-1 |
| 102 | GX5.3 | “Go” and “Not Go” Gauge for Bi-pin Base | 7006-73B-2 |
| 103 | GY5.3 | “Go” and “Not Go” Gauge for Bi-pin Base | 7006-73C-2 |
| 104 | 2G10 | “Go” Gauge for Caps on Finished Lamps | 7006-118-1 |
| 105 | GX10q | “Go” Gauge for Caps on Finished Lamps | 7006-84-2 |
| 106 | “Not Go” Gauge A for Caps on Finished Lamps | 7006-84A-1 |
| 107 | “Not Go” Gauge B for Caps on Finished Lamps | 7006-84B-1 |
| 108 | “Go” Gauges for Keys on Finished Lamps | 7006-84E-1 |
| 109 | “Not Go” Gauges for Caps on Finished Lamps | 7006-84F-1 |
| 110 | GY10q | “Go” Gauge for Caps on Finished Lamps | 7006-85-2 |
| 111 | “Not Go” Gauge A for Caps on Finished Lamps | 7006-85A-1 |
| 112 | “Go” Gauges for Keys on Finished Lamps | 7006-85D-1 |
| 113 | “Not Go” Gauges for Caps on Finished Lamps | 7006-85E-1 |
| 114 | G10q, GY10q | “Go” Gauge | 7006-79-2 |
| 115 | G12 | “Go” Gauge for Caps on Finished Lamps | 7006-80-1 |
| 116 | PG12,PGX12 Lamp Cap | “Go” Gauge | 7006-81-3 |
| 117 | Fc2 Lamp Cap | “Go” Gauge | 7006-114-1 |
| 118 | GR8 | “Go” Gauge for Caps on Finished Lamps | 7006-68-2 |
| 119 | GR8 | Gauge for caps to ensure entry of maximum lampholders and to check pin-spacing and length | 7006-68A-2 |
| 120 | GR8,GR10q | “Go” Gauge for checking the pins of caps on finished lamps | 7006-68E-1 |
| 121 | GR8,GR10q | “Go” and “Not Go” Gauge for checking the pins of caps | 7006-68F-1 |
| 122 | 2G13 Lamp Cap | “Go” Gauge | 7006-33-2 |
| 123 | 2G72GX7 Lamp Cap | “Go” and “Not Go” Gauge | 7006-102-1 |
| 124 | G23 Lamp Cap | “Go” and “Not Go” Gauge | 7006-69-2 |
| 125 | GX23 Lamp Cap | “Go” and “Not Go” Gauge | 7006-86-1 |
| 126 | G24GX24 Lamp Cap | “Go” and “Not Go” Gauge | 7006-78-3 |
| 127 | GX32 Lamp Cap | “Go” and “Not Go” Gauge | 7006-87-2 |
| 128 | G4 | “Go” and “Not Go” Gauge for Bi-pin Lamp Bases | 7006-72-1 A B |
| 129 | GU4 | “Go” and “Not Go” Gauge for Bi-pin Lamp Bases | 7006-108-2 |
| 130 | GZ4 | “Go” and “Not Go” Gauge for Bi-pin Lamp Bases | 7006-67-1 |
| 131 | G6.35GX6.35GY6.35GZ6.35 | “Go” and “Not Go” Gauge for Bi-pin Bases | 7006-61-5 |
| 132 | G6.35GX6.35GY6.35 | “Go” Gauge for Bi-pin Bases | 7006-61A-3 |
| 133 | GZ6.35 | “Go” Gauge for Bi-pin Bases | 7006-59B-1 |
| 134 | GU7 | “Go” and “Not Go” Gauge for Bi-pin Bases | 7006-113-2 |
| 135 | R17d | “Go” and “Not Go” Gauge | 7006-57-3 |
| 136 | Fa6 | “Go” and “Not Go” Gauge | 7006-41-2 |
| 137 | Fa8 | “Go” Gauge | 7006-40-1 |
| 138 | Fa8 | “Not Go” Gauge | 7006-40A-1 |
| 139 | 2G11 | “Go” Gauge | 7006-82-1 |
| 140 | B15 Lamp Holder | “Go” Gauge | 7006-12D-2 |
| 141 | B15d Lamp Holder | “Not Go” Gauge | 7006-12C-2 |
| 142 | Gauge for checking contact position and contact force in bayonet lampholders | 7006-15B-1 |
| 143 | Gauges for the slots in the lampholders | 7006-13-5 |
| 144 | E17 Lamp Holder | “Go” Gauge | 7006-25H-1 |
| 145 | “Not Go” Gauge | 7006-26C-1 |
| 146 | Gauges for testing contact-making in lampholers | 7006-26E-1 |
| 147 | E26 | “Go” Gauge | 7006-25B-2 |
| 148 | E26&E26d | “Not Go” Gauge | 7006-26A-2 |
| 149 | E26d | Plug gauge for testing protection against accidental contact in E26d lampholder | 7006-29J-1 |
| 150 | G6.35 Lamp Holder | Min. Retention Gauge | 7006-61C-4 |
| 151 | “Go” Gauge | 7006-61B-4 |
| 152 | G12 Lamp Holder | “Go” Gauge A | 7006-80A-2 |
| 153 | “Go” Gauge B | 7006-80B-2 |
| 154 | “Go” Gauge C | 7006-80C-2 |
| 155 | “Go” Gauge D | 7006-80D-3 |
| 156 | “Go” Gauge E | 7006-80E-3 |
| 157 | R7S | Gauges for testing contact-making | 7006-62-4 |
| 158 | G5.3 Lamp Holder | “Go” Gauge | 7006-73A-1 |
| 159 | GX53 Lamp Holder | “Go” Gauge A | 7006-142A-1 |
| 160 | “Go” Gauge B | 7006-142B-1 |
| 161 | “Go” Gauge C | 7006-142C-1 |
| 162 | “Go” and “Not Go” Gauge | 7006-142G-1 |
| 163 | “Not Go” Gauge | 7006-142H-1 |
| 164 | R7S Lamp Holder | “Go” Gauge | 7006-62-1 |
| 165 | GX5 Lamp Holder | “Not Go” Gauge | 7006-142J-1 |
| 166 | E5 Lamp Holder | “Go” Gauge | 7006-25F-1 |
| 167 | “Not Go” Gauge | 7006-25G-1 |
| 168 | E10 Lamp Holder | “Go” Gauge | 7006-25-7 |
| 169 | EP10 Lamp Holder | “Go” Gauge | 7006-37A-1 |
| 170 | E10 Lamp Holder | “Not Go” Gauge | 7006-26-4 |
| 171 | EY10 Lamp Holder | “Not Go” Gauge | 7006-26-4 |
| 172 | EP10 Lamp Holder | “Not Go” Gauge | 7006-26-4 |
| 173 | EY10 Lamp Holder | “Go” Gauge | 7006-7A-1 |
| 174 | E11 Lamp Holder | Gauges A for testing contact-making | 7006-6A-1 |
| 175 | Gauges B for testing contact-making | 7006-6B-1 |
| 176 | E12 Lamp Holder | “Go” Gauge | 7006-25C-1 |
| 177 | “Not Go” Gauge | 7006-26B-1 |
| 178 | Contact-making | 7006-32A-1 |
| 179 | E17 Lamp Holder | “Go” Gauge | 7006-25H-1 |
| 180 | “Not Go” Gauge | 7006-26C-1 |
| 181 | Gauges for testing contact-making | 7006-26E-1 |
| 182 | E26 Lamp Holder | “Go” Gauge | 7006-25B-2 |
| 183 | “Not Go” Gauge | 7006-26A-2 |
| 184 | E26d Lamp Holder | “Not Go” Gauge | 7006-26A-2 |
| 185 | E26 Lamp Holder | Gauges for testing contact-making | 7006-25J-1 |
| 186 | E26d Lamp Holder | “Go” Gauge | 7006-29K-1 |
| 187 | Gauges for testing contact-making | 7006-29G-3 |
| 188 | Gauge for checking the radial position of the intermediate contact of lampholder | 7006-29E-1 |
| 189 | Gauge for testing the relative positions of the contacts in lampholder | 7006-29F-1 |
| 190 | Gauge for testing contact-making in metal-shell paper-lined lampholders | 7006-29H-3 |
| 191 | Plug gauge for testing protection against accidental contact | 7006-29J-1 |
| 192 | Gauge for testing unacceptable contact-making in lampholders | 7006-29M-1 |
| 193 | E39 Lamp Holder | “Go” Gauge | 7006-24E-1 |
| 194 | “Not Go” Gauge | 7006-26-4 |
| 195 | Gauges for testing contact-making | 7006-24D-1 |
| 196 | Gauge for testing maximum insertion torque in lampholders with shell-grip features | 7006-24F-1 |
| 197 | Gauge for testing minimum insertion torque in lampholders with shell-grip features | 7006-24G-1 |
| 198 | E40 Lamp Holder | “Go” Gauge | 7006-25-7 |
| 199 | “Not Go” Gauge | 7006-26-4 |
| 200 | Gauges for testing contact-making | 7006-23-3 |
| 201 | Plug gauge for lampholders for testing protection against accidental contact | 7006-24-3 |
| 202 | Torque Test Cap | IEC 60238 Figure5 |
| 203 | GX53 Lamp Cap | “Go” and “Not Go” Gauge | 7006-142-1 |
| 204 | “Not Go” Gauge | 7006-142D-1 |
| 205 | “Go” and “Not Go” Gauge for checking keyways in caps | 7006-142E-1 |
| 206 | “Not Go” Gauge for checking keyways in caps | 7006-142F-1 |