| Working Dimensions: D×W×H | 2500×2500×2500MM, can be customized |
| External Dimensions: D×W×H | 4100X3100X3000MM, can be customized |
| Power (kw) | 13KW or depended on final design |
| Performance | Temperature Range | Working room temperature: -30 ℃ ~ 85 ℃ (dark cycle) |
| Humidity Range | 1. Lighting cycle: 10 ~ 60% RH 2. Humidity range of dark cycle: up to 100% 3. Humidity accuracy: ≤ ± 5% |
| Spectral Wavelength | 290-2450nm optional |
| Lamp Radiation Intensity | 1050W/m2 accuracy≦±0.01W/m2 |
| Lamp Tube Power | 2.5KW (Air-cooled full solar spectrum metal halogen lamps) |
| Lamp Total Power | 10KW, lifespan:1000 hours |
| Blackboard Temperature | BST control range: 80 ℃ (adjustable) BPT control range: 80 ℃ (adjustable) |
| Distance from Arc Center to Sample | 1200mm, effective exposure area ≥ 3000cm2 |
| | Sample Rack | 1200X1200MM, can be customized |
| | Accuracy Range | Setting / indication accuracy: temperature 0.1 ℃, humidity 1% RH |
| Temperature and Humidity Sensor | Platinum resistance.PT100Ω / MV |
| Heating System | Fully independent system, nickel-chromium alloy electric heater |
| Humidification System | External isolation type, all stainless steel shallow surface
evaporative humidifier |
| Blackboard Temperature | Bimetallic blackboard thermometer |
| Temperature Controller | Adopt Siemens color touch screen and German Siemens PLC module
control |
| Circulatory System | Temperature-resistant and low-noise air-conditioning motor.
Multi-blade centrifugal wind wheel |
| Material | Outer Chamber Material | High quality carbon steel plate, phosphating electrostatic spray
treatment / SUS304 stainless steel matte line hairline treatment |
| Inner Chamber Material | SUS304 high-quality stainless-steel smooth plate |
| Sample Rack Material | SUS304 high-quality stainless-steel bar | |
| Door Frame Insulation | High and low temperature aging silicone rubber door sealing strip | |
| Number of Sample Racks | The number of samples is 16, according to the blackboard
temperature and irradiation sensor | |
| Sun Eye | Intelligent irradiation induction loop system with German chip.
Automatically correct the setting value of irradiation intensity.
It is high temperature and high humidity resistance; shell is made
of 304 material. | |
| Standard Configuration | 1 set of anti-radiation glass windows, 4 lamps | |
| Safety Protection | Protection of electric leakage, short circuit, over temperature,
water shortage, motor overheat, over current | |
| Power Supply | AC380V±10% 50±0.5Hz three-phase five-wire system | |
| Use Ambient Temperature | 5℃~+30℃ ≤85%RH | |