Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test

Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test

Brand Name Sinuo
Model Number SN331
Certification Calibration Certificate (Cost Additional)
Place of Origin China
Minimum Order Quantity 1
Price Tailored
Payment Terms T/T
Supply Ability 1 Set Per Month
Delivery Time 2 Months
Packaging Details Plywood
UUT Air Conditioners & Heat Pumps
Chamber External Size 10000mm W×5000mm D×3500mm H
Indoor Size 4500mm W×4000mm D×3200mm H
Outdoor Size 4000mm W×4000mm D×3200mm H
Outdoor Temperature -10 ° C and up to 50 ° C
Detailed Product Description

 

3HP Air Enthalpy Method Calorimeter Testing Laboratory for Air Conditioners and Heat Pumps

 

Overview:

 

The test laboratory can accurately measure the air conditioning cooling capacity, heating capacity, cooling power consumption, heating power consumption, EER, COP, and inverter air conditioner’s rated / maximum / intermediate / minimum cooling capacity, rated / low temperature / intermediate / heating, cooling and heating power consumption, EER, COP, SEER and APF, etc.

 

The test laboratory can test 1~3PH household air conditioners. The test models cover all types of window, split wall mount, split cabinet and split ceiling cassette.

 

The test laboratory uses the air enthalpy method to measure the amount of cooling and heating capacity generated by the measured unit. The laboratory is divided into indoor and outdoor rooms. The indoor room mainly simulates the indoor working condition environment, and the outdoor room mainly simulates the outdoor working condition environment. The outdoor side temperature can be as low as -10 ° C and up to 50 ° C. Can meet the performance testing requirements of household air conditioning.

 

Standards:

 

Design and Testing according to the following standards:

► ISO 5151:2010

► ISO 16358:2013

► Other standards can be customized

 

Types of UUT :

 

- Split wall type

- Split cabinet type

- Split ceiling cassette type

- Window type

- Inverter air conditioner

 

Testing Range:

 

Test range

Cooling capacity

(W)

Heating capacity

(W)

Input power

(W)

Air Flow

(m³/h)

≤7500≤9000≤8000200~2000

 

 Indoor Size Dry bulb TemperatureIndoor Size Wet bulb TemperatureOutdoor Size Dry bulb TemperatureOutdoor Size Wet bulb TemperaturePower
Control Range0~50℃0~50℃-10~55℃0~55℃(Relative humidity control below 0°C,0~95%RH)0~8KW
Control Accuracy±0.2±0.2±0.2±0.2±0.5%
Display Accuracy±0.1±0.1±0.1±0.1±0.1%

 

Technical Indicators:

 

Working conditionsIndoor side air return condition of /℃Outdoor side air inlet condition of /℃
Dry bulb temperatureWet bulb temperatureDry bulb temperatureWet bulb temperature
Cooling operationRated coolingT127193524
T221152719
T329194624
Maximum coolingT132234326
T227193524
T332235231
Freeze-upT1211521-
T210-
T321-
Minimum cooling2115Minimum temperature recommended by the manufacturer

Condensation

Condensate removal

27242724
Heating operationHeat pump rated heatingHigh temperature2015(Max.)76
Low temperature21
Extra-low temperature-7-8
Maximum heating operation27-2418
Minimum heating operation20--5-6
Automatic defrost201221
Electric heating rated heating20---

 

System flowchart:

 

Product Tags: energy efficiency testing laboratory   energy efficiency lab test equipment  