China Electrical Appliance Testing Equipment manufacturer
Sinuo Testing Equipment Co. , Limited
Sinuo Testing Equipment Co., Limited
7
Home > Products > Energy Efficiency Lab >

30K BTU Single Code Test Laboratory Air Enthalpy Method Calorimeter

30K BTU Single Code Test Laboratory Air Enthalpy Method Calorimeter

Brand Name Sinuo
Model Number SN331-30K BTU
Certification Calibration Certificate (Cost Additional)
Place of Origin China
Minimum Order Quantity 1
Price Tailored
Payment Terms T/T
Supply Ability 1 Set Per Month
Delivery Time 2 Months
Packaging Details Plywood
Applied Standards ISO 5151, ISO 13253 , etc.
UUT Household Air Conditioners
Cooling Capacity 6000~30000Btu/h
Heating Capacity 6000~30000Btu/h
Indoor Temperature 10 ° C~50 ° C
Outdoor Temperature -20 ° C~60 ° C
Indoor Humidity 35%~90%
Outdoor Humidity 25%~90%
Detailed Product Description

 

30K BTU Single Code Test Laboratory Air Enthalpy Method Calorimeter

 

System overview

This air enthalpy method calorimeter lab designed and manufactured by consists of 1 indoor side room(Room A)and 1 outdoor side room(Room B). The refrigerating capacity, heating capacity and other performances of an air conditioner are tested by means of testing the lab parameters, such as temperature, pressure and electrical performance. This installation can be used to test the performance of various window type, split type, free-standing type and ceiling cassette type and duct type AC air conditioners, and can also be used for other standard operating condition related tests and expanded tests, meeting the need for product sampling inspection and product development. The laboratory is equipped with one station, which can test 1 set of 3-Phase prototypes not larger than 30KBtu.

 

In this test system, the operation of the equipment is controlled by a programmable controller and a HMI, test running data are collected by a high accuracy data collector, the data can be transferred at real time to an upper level computer for processing, the computer displays, stores, outputs and prints test reports.

 

According to standards

Design and Testing according to the following standards:

► ISO 5151:2010, ISO 13253

► IEC 60335-2-40

► JISB 8615, JISB8616

 

Types of UUT

-Split type

-Window type

-Free-standing type

-Ceiling cassette type

-Duct type

-Inver-frequency air condition

 

Test contents

► Rated cooling capacity (T1, T2, T3).

► Rated heating capacity (High, Low, Extra-low)

► Airflow

► Dehumidification capacity

► Input power

► EER(COP)

► Frequency

► Current

► Voltage

 

Measurement Accuracy and Repeatability

 Measurement accuracyRepeatability accuracy
Testing methodCompared with standard machineAverage deviation from 3 tests once installed
Items  
Cooling capacity±2% beneath±1% beneath
Heating capacity±2% beneath±1% beneath
 

Chamber dimensions

► External dimensions (mm): 12500W×4000D×3500H; (Contain Control room & Machine room)

-Room A (30K Indoor side room) dimensions (mm): 5000W×4000D×3500H;

-Room B (30K Outdoor side room) dimensions (mm): 4000W×4000D×3500H;

► Materials: δ=100mm rigid polyurethane foam insulation, 0.6t color steel plate on inside and outside walls and ceiling, ID Room 2.5t stainless steel floor covered with 0.6t color steel plate, OD Room 3.0t stainless steel floor covered with 0.6t color steel plate.

► Doors: Single door (mm): 1200W×2500H,(2 set);

► View windows(mm): 400W×500H,(2 set)

 

 

 

 