LCD Display Patient Monitor Machine / Hospital Vital Sign Machine
|
LCD Display Patient Monitor Machine / Hospital Vital Sign Machine
FL-PM8000 Introduction
The monitor has abundant functions that can be used for clinical monitoring with adult, pediatric and neonate. Users may select different parameter configuration according to different requirements. The monitor, power supplied by 100-240V~,50/60Hz, adopt 12.1” color TFT LCD displaying real-time date and waveform. It can synchronously display eight-channel waveform and full monitoring parameters equipped with an optional 48mm thermal recorder. The monitor can be connected to the central monitoring system via wire or wireless network to form a network monitoring system. This device can monitor such parameters as ECG, RESP, NIBP. SpO2, and dual-channel TEMP, ect. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. Its replaceable internal battery brings lot of convenient for patient moving. Functions Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP ECG Heart rate(HR) ECG waveform Arrhythmia and ST-segment analysis RESP Respiration rate(RR) Respiration waveform SpO2 Oxygen saturation(SpO2) Plethysmogram(PLETH) waveform Pulse rate(PR) Bar graph NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN) TEMP TI, T2, TD IBP(optional) CH1: SYS, DIA, MAP CH2: SYS, DIA, MAP IBP waveform CO2(optional) EtCO2 InsCO2: Inspired Minimum CO2 AWRR: Air Way Respiration It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc. Accessories Adult fingertip SpO2 probe (5-pin) Adult NIBP cuff NIBP extension tube ECG lead cable ECG electrode Temperature probe Power cord User Manual Physical characteristic Dimension: 314 mm(L) x 145 mm(W) x 264 mm(H) Weight: <3.9 kg(excluding battery and accessories) Performance ECG Lead mode: 3-lead: 1, II, II 5-lead: I, II, II, aVR, aVL, aVF, V Waveform: 3-lead, 1-channel 5-lead, 2-channel Gain: 2.5 mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV, 40 mm/mV Scan speed: 12.5 mm/s, 25 mm/s, 50 mm/s HR: Measurement and alarm range: 15-350 bpm Resolution: 1 bpm Accuracy: +1% or ±1 bpm, whichever is greater Alarm accuracy: ± 2 bpm ST-segment monitoring: Measurement and alarm range: -2.0 mV ~+2.0 mV Accuracy: -0.8 mV~ +0.8 mV: ±0.04 mV or ± 10%, whichever is greater Other range: unspecified Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Pacemaker: yes
RESP Method: R-F(RA-LL) Impedance Respiration rate: Measurement and alarm range: 0~150 rpm Resolution: 1 rpm Measurement accuracy:±2 rpm Apnea alarm: 10 - 40 s Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
NIBP Method: Oscillometry Mode: Manual/AUTO/STAT Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes Measurement period in STAT mode: 5 minutes Measurement and alarm range: 10 - 270 mmHg Resolution: 1 mmHg Cuff pressure accuracy: + 3 mmHg Measurement accuracy: Maximal mean deviation: ±5 mmHg Maximal standard deviation: 8 mmHg
NIBP Over-pressure protection: Adult mode: 297 mmHg ± 3 mmHg Pediatric mode: 240 mmHg ± 3 mmHg Neonatal mode: 147 mmHg ± 3 mmHg SpO2 Measurement and alarm range: 0~100 % Resolution: 1% Accuracy:70~100 %: ±2 %; 0 ~ 69 %: unspecified
PR Measurement and alarm range:25~250 bpm Measurement accuracy: ±2 bpm or ± 2 %, whichever is greater
TEMP Channel: dual-channel Measurement and alarm range: 0 ~ 50℃ Resolution: 0.1 ℃
Accuracy: ± 0.1 ℃
EtCO2 Method: Sidestream or Mainstream Measuring Range: 0~150 mmHg Resolution: 0 ~ 69 mmHg: 0.1 mmHg, 70 - 150 mmHg: 0.25 mmHg Accuracy: 0 - 40 mm Hg: ±2 mm Hg,41 - 70 mm Hg: ± 5 %, 71 - 100 mm Hg: ± 8 %, 101 - 150 mm Hg: ± 10 % AWRR Range: 2~150 rpm AWRR Accuracy: ±1rpm Apnea Alarm: Yes
IBP Channel: dual-channel Label: ART, PA, CVP, RAP, LAP, ICP, PI, P2 Measuring and Alarm Range: -10 ~ 300 mmHg Resolution: 1 mmHg Accuracy: ± 2% or 1mmHg, whichever is greater Power supply: 100-240V, 50/60 Hz Safety classification: Class I, type CF defibrillation-proof applied part |
Product Tags: vital sign monitors monitoring machine in hospital |