Human Covid-19 Virus Detection Test Kit IgM/IgG Rapid Antibody Test Kit
|
Detailed Product Description
2019-nCoV IgG/IgM Antibody Rapid Test Kit (Colloidal gold Assay) TEST PROCEDURE 1. Please read the manual of the kit before operation. 2. If the sample is stored refrigerated or frozen, please allow the
sample to fully melt at room temperature (20-30 ° C), and mix the
sample upside down before use. 3. Before starting the test, remove the test strip from the
aluminum foil bag, lay it flat on the table, and mark the sample
number. 4. Use a sample gun or a dropper to draw 10ul of the sample to be
tested (serum, plasma or whole blood sample) into the sample well
on the test card. Immediately add 2 drops (70-90ul) of the sample
dilution solution to the sample well, and avoid significant bubbles
during operation. 5. Count and read the results within 15 minutes at room
temperature. Please strictly control the reaction time and read the result
within 15 minutes. Interpretation of test results The test results are divided into three cases: negative, positive
or invalid. The specific interpretation methods are as follows:
LIMITATIONS OF THE TEST 1. This reagent is a qualitative test and cannot be used for
quantitative determination of antibody content. 2. This reagent is used for the detection of human whole blood,
serum or plasma samples. It cannot be used for the detection of
saliva, urine or other body fluids. 3. The test results of this product are for clinical reference only
and should not be used as the sole basis for clinical diagnosis and
treatment. The clinical management of patients should be considered
in combination with their symptoms / signs, medical history, other
laboratory tests, treatment response, and epidemiology. 4. In the early stage of infection, if the virus-specific IgM
antibody is not produced or the titer is very low, it will lead to
negative results. If a virus infection is suspected, the patient
should be reminded to check again within 10-20 days and take a
second sample, which should be the same as the first sample.
Simultaneously test under conditions to determine if there is a
seroconversion or a virus-specific IgG or IgM antibody titer that
is significantly higher in the first infection. 5. The interpretation of positive results should be further
determined in conjunction with clinical symptoms and other
etiological methods (nucleic acid and sequencing). 6. Negative results indicate that no new coronavirus IgM / IgG
antibodies have been detected, but if the new coronavirus IgM / IgG
antibody content in the sample is below the minimum detection limit
of the kit, negative results may also be obtained.
PACKAGE 10 Test/Box; 25 Test/Box; 50 Test/Box; 100 Test/Box. INTENDED USE It is used for the qualitative detection of novel coronavirus IgG
and IgM antibodies in human serum, plasma or whole blood in vitro. Coronavirus is a large family that exists widely in nature. It is
susceptible to humans and many animals. It is named for its
corona-like fibroids on the surface of its virus particles. The typical clinical symptoms of the new coronavirus (2019-nCoV)
infection are fever, fatigue, muscle soreness, and dry cough, which can progress to
severe pneumonia, respiratory failure, and even life-threatening. Current evidence indicates that the new coronavirus is transmitted
mainly through droplets, aerosols, and direct contact with
secretions. After humans are infected with the new coronavirus
(2019-nCoV), the human immune system will generate an immune
response against the virus, producing specific antibodies.
Detection of relevant antibodies can be used to screen for
infection with the new coronavirus. Therefore, it is of great
clinical significance to establish a simple, safe and reliable new
method for laboratory diagnosis of coronavirus. SAMPLE REQUIREMENTS Clinical fresh non-hemolyzed serum, plasma or whole blood (EDTA
anticoagulation) samples. After sampling, the sample should be tested within 24h at room
temperature. The sample should be stored for no more than 5 days in
cold condition of 2-8°C and should be stored for no more than one
month in cryopreservation condition of -18°C. The whole blood
sample should be stored for no more than five days at 2-8°C if it
can’t be tested within two hours after sampling. The sample needs to be restored to room temperature before testing.
Cryopreserved samples need to be completely melted, rewarmed, mixed evenly before
use, avoid freezing and thawing repeatedly. |
||||||||||||||||||||||||||||||||
Product Tags: rapid test kit antibody test kit |
Related Products
![]() |
Covid-19 Virus Detection Test Kit Accurate One Step Rapid Test Kit OEM |
![]() |
Personal Use Covid-19 Virus Detection Test Kit Rapid Detection Kit 10 Test / Box |
![]() |
One Step Covid-19 Virus Detection Test Kit Diagnostic Reagent Test Kit With Ce Iso |
![]() |
Covid-19 virus detection IgM/IgG Antibodies Test Kit corona virus rapid test kit |
![]() |
Human Covid-19 Virus Detection Test Kit IgM/IgG Rapid Antibody Test Kit |
Email to this supplier