China Machine Vision LED Lighting manufacturer
OPT Machine Vision Tech Co., Ltd.
To be a global first-class machine vision enterprise and to create a platform for our staff to succeed with self-value.
6
Home > Products > Machine Vision Controller >

2A 12-48VDC Machine Vision Controller SPM Mini Led Strobe Controller External Trigger

2A 12-48VDC Machine Vision Controller SPM Mini Led Strobe Controller External Trigger

Brand Name OPT
Model Number OPT-SPM2024-1
Place of Origin China
Minimum Order Quantity 1 piece
Price Negotiable
Payment Terms T/T
Supply Ability Negotiable
Delivery Time 7 work days at the soonest
Packaging Details Craft Box
Product name SPM Mini Strobe Controller
Model OPT-SPM2024-1
Input Voltage 12 - 48V DC
External Trigger Yes
Channels 1
Standby Power Consumption ≤1W
Dimensions(L*W*H) 113.4mm*24.1mm*25.3mm
Weight(kg) 0.1kg
Detailed Product Description

2A Machine Vision Controller SPM Mini Strobe Controller 12 - 48V DC External Trigger OPT-SPM2024-1

 

Product Features

◆ Compact space designing
◆ Up to 50kHz trigger response frequency
◆ The trigger response time is no more than 10μs.
◆ 6 trigger polarities are available for various working environments
◆ Wide input voltage range: 12 - 48V DC; It's much convenient to use the DC power on other devices, and to increase strobe intensity.
◆ Trigger pulse width range: 10μs - 1023ms
◆ Input voltage is 12 - 48V DC; current of controller is 2A.
◆ Illumination mode: strobe mode
◆ The way of trigger is external trigger.
◆ Less than 10µs response time 
◆ 1 Channel is available to connect mini strobe controller with light sources.
◆ Standby power consumption of controller is no more than 1 Watt.
◆ Dimensions(L*W*H):113.4mm*24.1mm*25.3mm
◆ Max. transient output current is 4A.
◆ Protection forreverse polarity connection is available.
◆ Trigger polarity: 
1. Rising edge trigger
2. Falling edge trigger
3. Positive follow trigger mode
4. Negative follow trigger mode
5. Time limited positive trigger
6. Time limited negative trigger
◆ Trigger level: Low level: 0 - 2V, High level: 5 - 24V
◆ Trigger pulse width: 10µs~1023ms

◆ Output voltage: Max. constant output current: 2A; Max. transient output current: 4A

◆ External trigger is available.

Model Meaning

 

OPT-SPM2024-1
 
OPT: Brand name
SPM: Mini strobe controller
20: Max. output current: 2A
24: Output voltage: 12 - 48V
1: Channels

 

Specifications

ModelOPT-SPM2024-1
Voltage12 - 48V DC
Current2A
Illumination ModeStrobe
TriggerExternal trigger
Response Time10µs
Response Frequency≤50KHz
Channels1
Standby Power Consumption≤1W
Dimensions(L*W*H)113.4mm*24.1mm*25.3mm
Operating Temperature-5℃~50℃
Weight(kg)0.1kg
Max. Transient Output Current4A
Protection Forreverse Polarity ConnectionYes
Trigger Polarity

1. Rising edge trigger 2. Falling edge trigger

3. Positive follow trigger mode  4. Negative follow trigger mode

5. Time limited positive trigger  6. Time limited negative trigger

Trigger Level

Low level: 0 - 2V

High level: 5 - 24V

Trigger Pulse Width10µs~1023ms
Output Voltage

Max. constant output current: 2A

Max. transient output current: 4A

External TriggerYes

 

 

Device Overview

                                            

                                               

                                         

 

                                                                                                                                                                                 

Product Details

                                                   

                                          Input connection

                                          The input port is formed by 4 wires of different colors, which has optocoupler inside.
                                          See the chart below for their connection with power anode and cathode.
                                          Low level: 0 - 2V input; high level: 5 - 24V input
                                          Please refer to the “Wiring Diagrams” for more details.

    

                                                     

 

                                                           Positive follow trigger mode
                                                           When the trigger signal is at high level, the illumination time
                                                           is the same as the high-level pulse width.
                                                     
                                                          Negative follow trigger mode
                                                          When the trigger signal is at low level, the illumination time
                                                          is the same as the low-level pulse width.

                                                            

                                                                   

 

                                                           

                                                               When the trigger signal is at low level, if the pulse width≥ the preset value,
                                                               the illumination time is the same as the preset value.
 
                                                           
                                                               Remarks
                                                               T1: Enabling response time ≤ 10μs;
                                                               T2: Trigger pulse width, range: 10μs - 1023ms
                                                               T3: Disabling response time ≤ 10μs
 
                                                          
 
                                                            Notes
                                                            1. Sx.x indicates the exact switch. E.g. S2.1 is the first switch of S2
                                                                and S2.2 the second switch of S2, and so on.
                                                            2. Pulse width values can be presented with the 10 binary numbers
                                                                formed by the switches from S2.10 (the highest bit) to S2.1 (the
                                                                lowest bit). ON indicates 1, and OFF 0.
                                                            3. When μs is the unit of trigger pulse width, the pulse width is 10μs
                                                                if the preset value is ≤ 10.

                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              

Dimensions (mm)
OPT-SPM2024-1
                                                            

 

                             

 

 

 

 

Product Tags: 48VDC Machine Vision Controller   2A Machine Vision Controller   48VDC Led Strobe Controller  