Shockproof Electric Power Tester
|
|
VICTOR5000 Power Quality Analyzer Large LCD Screen Display High Resolution Shock-Proof Shell StructureTrue RMS
Brief Introduction Power Quality Analyzer is a comprehensive test instrument carefully developed by our company and specially designed for field test of three phases, multi-functional and intelligent, concise man-machine operation. It is easy to use, large LCD screen display, high resolution, interface in both Chinese and English, shock-proof shell structure and so on. Can simultaneously measure the 4-channel current (ABC three phase and neutral wire current), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current voltage, maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor and displacement power factor, active power, reactive power, apparent power, total harmonic distortion and harmonic, etc; Display real-time waveform, harmonic ratio bar charts of current voltage; Dynamically capture instantaneous change of voltage current, monitoring starting current, monitoring the power parameters and generate the alarm list, generate the trend chart for a long time record test data.
In the current power applications, more and more large power equipment, power grid fault have become more and more complex, with development of the industry, it put forward high request more and more to quality that electric energy. We provide this power quality analyzer for that, which you can troubleshoot of complex power system more quickly and accurate, and monitoring and maintenance of power quality parameters more comprehensive and systemic.
Power quality analyzer adopt DSP + ARM double processor architecture, DSP is use for data collection and the processing of algorithm, the ARM is use for the communication protocol and the man-machine interface processing; Analog signal acquisition is by 2 pieces AD7655 of ADI company. Resolution for AD7655 is 16 bit and it is 4 channel synchronous sampling. The highest sampling rate can reach 1 MSPS, to ensure the accuracy of the channel and the information integrity, and wouldn’t miss any transient changes in the grid, can more accurate to detect the transient waveform rising and dropping drastically, and waveform instantaneous interrupt; DSP working frequency is over 200 MHZ, to be able to timely monitoring of the power grid and dynamically adjust the sampling frequency to realize synchronization of power frequency and sampling frequency; Using a 5.6 -inch LCD color screen display, a resolution of 640 dots x 480 dots, with different display color difference between the parameters of phase, waveform, vector diagram, harmonic ratio, the user can be more efficient and more intuitive understand the state of power grid parameters. Built-in flash memory can store 60 group of screenshots at the same time, 150 groups of capture transient voltage/current waveform figure, and 12800 groups of alarm list. Starting current detection model can continuously capture starting current waveform for 100 s. Built-in 2G memory card to store the trend curve record, simultaneous recording 20 parameters (can choose according to need) collect data for once every five seconds, trend curve records can be stored for 300 days.
Power Quality Analyzer also named: Intelligent Three Phase Power Quality Analyzer, Multifunctional Power Quality Analyzer, which simultaneous with the functions of harmonic Analyzer, phase volt-ampere meter, electric parameter tester. It apply to electricity industry, petrochemical, metallurgy, railway, mining enterprises, scientific research institution, metrological department. Especially suitable for comprehensive analysis and diagnosis on all the voltage, current, power, power, harmonic, phase electric parameters. 1.2. Function1.2.1. Basic function★ Waveform real-time display (4 channels voltage/4 channels current). ★ True RMS values of voltages and currents. ★ The DC components of voltages. ★ Peak current and voltage values. ★ Minimum and maximum half-cycle RMS current and voltage values. ★ Pharos diagram display. ★ Measurement of each harmonic up to order 50. ★ Bar charts show harmonic ratios of current and voltage of each phase. ★ Total harmonic distortion (THD). ★ Active, reactive, apparent power, by phase and cumulative. ★ Active, reactive, apparent energy, by phase and cumulative. ★ Transformer K factor. ★ Power factors (PF) and displacement factors (DPF or COSΦ). ★ Short-term voltage flicker (PST). ★ Three phase unbalance(current and voltage).
Technology specification Base condition and working condition
1.3.2. General specification
Instrument precision (excluding the current sensor)Respectively introduce the following data (on the basic of base conditions and the ideal current sensors, perfectly linear, no phase shift).
1.3.4. Current sensor character
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: Shockproof Electric Power Tester VICTOR 5000 Electric Power Tester Shockproof Power Quality Analyzer | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
VICTOR 90B high voltage approach electric alarm helmet type voltage alarm high voltage electric shock |
|
VICTOR 90A 90B high voltage approach electric alarm none contact voltage alarm function high voltage electric shock |
|
AC 200V Electric Power Tester |
|
Shockproof Electric Power Tester |
|
Clamp Leaker Function Measurement Of AC Leakage Current, AC Current And On-Line AC Current Four Bits LCD Display |
|
Anti Interference Dia 200mm Electric Power Tester Leakage Current Clamp Meter |