China VICTOR Digital Multimeter manufacturer
XI'AN BEICHENG ELECTRONICS CO.,LTD
The Best Quality, The Best Service!
6
Home > Products > Digital Earth Resistance Tester >

AC True RMS Digital Earth Resistance Tester 3 Pole 4 Pole Method Measurement

AC True RMS Digital Earth Resistance Tester 3 Pole 4 Pole Method Measurement

Brand Name VICTOR
Model Number 4106A
Certification CE
Place of Origin CHINA
Minimum Order Quantity 50pcs
Price USD75/PC
Payment Terms T/T, Western Union, L/C,Paypal
Supply Ability 10000 pc available
Delivery Time 5-30 days
Packaging Details Color box ,8pcs/Carton ,22.80KG/Carton
Packing digital earth resistance meter
Color Black and Blue
Weight Approx 680g
Max display 1999
LCD size 84.8*59.8mm
Measuring range 0.02Ω~1999Ω
Battery 5 alkaline battery
Accuracy 2% accuracy
Detailed Product Description

AC True RMS Digital Earth Resistance Tester 3 Pole 4 Pole Method Measurement

 

VICTOR 4106A Earth Resistance Tester 3-Pole 4-Pole Method Measurement AC True RMS Large LCD Display With LED Backlight

 

Basic features of the product

Basic measurement functions

Earth resistance measurement (RE)

Measurement method: 3-pole method, 4-pole method

Measuring range: 0.02Ω~1999Ω

Minimum resolution: 0.01 Ω

Basic accuracy: 5%

 

Soil resistivity measurement (ρ)

Measurement range: 0.01Ω·m~376.8KΩ·m

Interval of auxiliary earth rods, setting range: 1.0 m ~ 30.0 m.

AC true RMS voltage E.V

Measurement range: 0~50V

AC bandwidth: 40Hz ~ 200Hz

Measurement basic accuracy: 2%

 

Earth test other features

Earth resistance measurement adopts square wave excitation test, the maximum open-circuit voltage is 50Vp-p, and the short-circuit current is <3mA.

Automatic range detection in earth resistance measurement.

RK resistance test, the line resistance effect can be removed.

Earth comparison test, the measurement result can be evaluated by the preset "pass/fail (✓ / ✘)" limit and be given audio alarms accordingly.

Product calibration

By connecting with the standard instrument, calibrating panel according to the procedures and saving the appropriate calibration data, the periodic calibration is completed and the due accuracy and performance of the product are guaranteed.

Large LCD display with white LED backlight.

Easy man-machine operation, portable, solid and suitable for field use.

 

Product basic functions and performance (technical data)

(applicable for one year after calibration, 23℃±5℃, 0~70%RH, accuracy = ±(%reading+LSD))

 

AC voltage E.V

Measurement rangeResolutionFrequency rangePrecision
0.00V~50.00V0.01V45 ~ 200Hz sine2%+5

Input resistance: about 1MΩ

Measurement rate: 2 times/s .

 

Earth resistance RE (RG when testing ρ)

RangeMeasurement rangeResolutionPrecisionRemarks
20Ω0.10Ω~19.99Ω0.01Ω5%+5

0.2 Ω error is added when the resistance is less than .

RH and RS are 500ΩRk corrected data.

200Ω20.0Ω~199.9Ω0.1Ω
2000Ω200Ω~1999Ω

Output features: test open circuit voltage UM, the maximum is around 50Vpp, square wave

Test the short circuit current IM, the maximum is around 3mApp, but IM(RH +RE)< UM

Measurement time: typical 2 seconds.

RH MAX: (4K Ω+100RE) or 50KΩ (whichever is lower).

RS MAX: (4K Ω+100RE) or 50KΩ (whichever is lower).

Additional error at RH MAX or RS MAX: 3%+10.

Series interference voltage: 16·2/3Hz, 50Hz, 60Hz, 400Hz and DC 3V (20Ω range does not include DC).

Additional error at 3V series interference voltage: 5%+10.

 

Soil resistivity (ρ) measurement

RangeMeasurement rangeResolutionPrecision
20Ω·m0Ω·m~19.99Ω·m0.01Ω·m

Depends on RG

ρ=2×π×a×RG

200Ω·m20.0Ω·m~199.9Ω·m0.1Ω·m
2000Ω·m200Ω·m~1999Ω·m1Ω·m
20KΩ·m2.00KΩ·m~19.99KΩ·m0.01KΩ·m
200KΩ·m20.0KΩ·m~376.8KΩ·m0.1KΩ·m
The distance between the earth rods: a=1.0 m ~ 30.0 m.

 

General features of the product

Operating temperature and humidity

0 to 40ºC (non-condensing ≤10ºC), ≤85%RH

Storage temperature and humidity: -20ºC to 60ºC,≤90%RH

Working altitude:≤2000m.(Indoor use)

Rated transient overvoltage:6K (1.2*50us) I, II, III measurement peak value

Withstand voltage:AC8320V(50/60Hz)/5 seconds (between the circuit and the outer box)

Insulation impedance:1000MΩ or greater/DC1000V (between the circuit and the outer box)

Vibration and shock:Randomness 2g, 5 to 500Hz 1m drop test

Calibration period and warm-up time

To ensure the accuracy of this table, the calibration period is one year or other

The warm-up time after turned on is 10 minutes or other

Power supply:Powered by 8 x 1.5 V LR6(AA) alkaline batteries

15V power adapter power supply

Automatic shutdown operation: automatic shutdown time 0~90 minutes can be set

Size and weight:178 × 110 × 59 (mm), about 600g (including batteries)

  • Product accessories
  • Standard configurationTest kit
  • (Red:15 m; black/green: 5 m; yellow: 10 m) - 1 set
  • Earth steel chisel - 4
  • Product manual - 1
  • #5 alkaline battery - 8
  • Printed box - 1
  • Cloth bag - 1
  • Handle rope - 1
  • Optional accessories
  • 15V power adapter - 1

Product Tags: True RMS Digital Earth Resistance Tester   4106A Digital Earth Resistance Tester   4106A digital earth resistance meter  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: XI'AN BEICHENG ELECTRONICS CO.,LTD
Subject:
Message:
Characters Remaining: (80/3000)