China Ag Rapid Test Kit manufacturer
Henan Lantian Medical Supplies Co.,Ltd.
The company always adheres to the core concept of "fast and accurate, live up to life", and is committed to providing excellent products and services for the society and contributing to the
5
Home > Products > Troponin I Rapid Test Kit >

Combined Myo CK-MB Troponin I Rapid Test Kit 15min 60ul Sample

Combined Myo CK-MB Troponin I Rapid Test Kit 15min 60ul Sample

Brand Name Combined detection reagent of troponin I, myoglobin and creatine kinase isoenzyme(cTnl/MYO/CK-MB)
Model Number cTnl/MYO/CK-MB
Certification CE
Place of Origin China
Minimum Order Quantity To be negotiated
Price To be negotiated
Supply Ability 10000 Kit/Kit per Day
Delivery Time To be negotiated
Packaging Details Kit
Sample type Whole Blood,Serum,Plasma
Mixing requirements Mix well
Sample size after dilution sixty μl
Test time 15min
Detection range cTnl:0.1~50ng/mL;MYO:10~200ng/mL;CK-MB:0.8~100ng/mL
Application Department Outpatient, emergency
Detailed Product Description

Combined Detection Reagent Of Troponin I,Myoglobin And Creatine Kinase Isoenzyme Clinical Significance In Emergency

 

CTnI/MYO/CK-MB Overview


Myoglobin I/myoglobin/creatine kinase isoenzyme (cTnI/Myo/CK-MB) contains the following three markers: significance in the early diagnosis of acute cardiomyopathy such as AMI.

 

American Institute of Clinical Biochemistry (NACB) clinical guidelines

All patients suspected of having ACS should be examined for markers of myocardial necrosis.

Troponin is the main diagnostic index of myocardial infarction

Myoglobin binding to specific markers of myocardial necrosis (such as cTnI/CK-MB) may help to rule out or diagnose myocardial infarction more quickly.

 

 

 MYOCK-MBcTnI
molecular weight17.8KD86KD22.5KD
Rise time1-2h4-6h3-6h
Peak time6-9h24h12-16h
recovery time18-30h2-3d4-10d
Clinical value

1. The most important AMI indicator was excluded early

2. The highest evaluation index of AMI recurrence diagnosis and reperfusion treatment effect

1. Estimate infarct size or reinfarct

2. MI's most valuable non-ST segment height markers

1. Preferred marker for AMI diagnosis

2. Judgment of infarction size and risk stratification

 

 

cTnI/MYO/CK-MB Performance Index


Detection rangesample sizeSample typeTest time
cTnIMYOCK-MB60μlWhole blood / serum / plasma15min
0.1~50ng/mL10~200ng/mL0.8~100ng/mL

 

 

 

CTnI/MYO/CK-MB Clinical Significance


  • It is helpful for early diagnosis and risk stratification of acute coronary heart disease.
  • The site of myocardial ischemia injury was determined
  • Differential diagnosis of multiple causes of chest pain
  • Monitoring of multiple causes of myocardial injury
  • Evaluation of the clinical efficacy of a specific agent.

 

Possibility of outcome 
cTnICK-MBMYOClinical possibility

+

++Myocardial infarction/myocardial injury is basically diagnosable with a duration of 12-24 hours.
++-The basic diagnosis was myocardial infarction/myocardial injury, and the detection time was more than 1 day, which exceeded the detection window time of Myo
+--Myocardial infarction/myocardial injury can occur within 2-3 days, and it is best to return to the doctor a few hours later.
+-+In patients with myocardial infarction/injury, symptoms may take longer than 3 days to develop and the patient may experience reinjury or infarction enlargement.
-++For early myocardial infarction/myocardial injury/muscle injury, cTnI review is recommended within 4-8 hours.

-

-+1. For early myocardial infarction/myocardial injury, cTnI review is recommended within 4-8 hours.
2. It can also be caused by other impairments, such as creative work, skeletal muscle damage, and liver and kidney disease.
-+-1. For mild myocardial injury, cTnI is recommended to be reexamined within 4-8 hours.
2. It may be non-myocardial injury, and the detection time exceeds the Myo window time.

-

--Myocardial infarction or myocardial injury was basically ruled out. If in doubt, it is best to check every 2 to 4 hours.

 

 

 

Application Department


Outpatient, emergency, physical examination center, cardiovascular, ICU, chest pain center and other departments

 

 

CTnI/MYO/CK-MB Clinical Comparison


 

 

Company profile


Zhongxiu Science And Technology Co.,Ltd., is a high-tech enterprise engaged in the research and development, production and operation of in vitro diagnostic products. The in vitro diagnostic products developed by the company cover POCT series, microbial series, biochemical series and immune series reagents and supporting instruments.
The company has always adhered to the core concept of "fast and accurate, living up to life", committed to providing society with excellent products and services, and contributing to the cause of human health.

 

 

 

 

Product Tags: Myo CK-MB Troponin I Rapid Test Kit   60ul Sample Troponin I Rapid Test Kit   Combined Myo CK-MB Test Kit  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Henan Lantian Medical Supplies Co.,Ltd.
Subject:
Message:
Characters Remaining: (80/3000)