Spd Protection Zinc Oxide Lightning Arrester Din Rail Mounted
|
IEC Standard Lightning Arrester Din Rail Mounted For Spd Protection
#4. Multiple-Gap Arrester: Multiple-Gap Arrester
Arresters of this type are designed to be small metal cylinders in series. Which are separated from each other by means of air and are insulated from each other.
Whose first cylinder is connected to the line and the last and its next cylinder in series connected to the earthing. The intermediate cylinder has a shunt barrier at some intervals. The distance between the cylinders depends on the voltage of the line.
#5. Electrolytic Arrester: Arresters of this type have a large discharge capacity only. It works in such a way that a thin strip of aluminum hydroxide is deposited on the electrolyte completely immersed on the aluminum plates. The plate acts as high resistance to low cost but fixed value. Less resistance to voltages than. Puncture at a voltage of more than 400 volts and causes the free flow of current to the earth.
When the voltage remains at its normal value of 440 volts, the arrester again provides high resistance in the path and stops the leakage.
#6. Expulsion Type Lightning Arrester: Arresters of this type have an improvement in the distance of the rod in which it shuts off the frequency of power. This air raster uses a tube made of fiber which is very effective, separating the spark gap and the interrupted spark gap inside the fiber tube.
Expulsion Type Lightning Arrester
The spark of impulse inside the fibrous tube during operation destabilizes some of the fibrous material of the arc tube in the form of gas, which is called a vent from the bottom of the tube. Thus, extinguishing the arc is just like circuit breakers.
Advantages of Lightning Arrester: The benefits of Lightning Arrester are as follows:
Damage caused by lightning can be minimized. Easy to use. Provides protection of equipment outside the substation. Damage to the overhead line can be avoided. Outlet surgeries can be avoided. Electromagnetic interference. Disadvantages of Lightning Arrester: The Disadvantages of Lightning Arrester are as follows:
Prevents excessive space in the line. Installation costs are higher.
Packaging & Shipping
Q: Can we get a sample for reference?
|
||
Product Tags: Spd Protection Zinc Oxide Lightning Arrester 11KV Zinc Oxide Lightning Arrester Din Rail Mounted Lightning Surge Protector |
![]() |
50KV/M RS485 Lightning Protection Electric Field Meter System |
![]() |
3 Phase Lightning Arrester Din Rail Mounted IEC Standard For Spd Protection |
![]() |
Metal 11KV Lightning Arrester Din Rail Mounted For Spd Protection |
![]() |
Din Rail Mounted Lightning Surge Arrester Customized 3-220kV For Spd Protection |
![]() |
3 Phase Lightning Arrester Din Rail Mounted IEC Standard For Spd Protection |
![]() |
Spd Protection Zinc Oxide Lightning Arrester Din Rail Mounted |