100% High Sensitivity TP Syphilis Qualitative Detection Cassette
|
Treponema Pallidum(TP) Rapid Diagnostic Kit (Colloidal Gold)
For the qualitative detection of Syphilis antibodies in serum/plasma and whole blood
Main Features:
♦ High Sensitivity: 100% ♦ Specificity: 100% ♦ Reliable: Accuracy higher than 97.5%, early detection of the presence of TP Antibody ♦ Simple: No Instrument Required ♦ Convenient: Room Temperature Storage, Built-In Control ♦ Fast: Results in 5-30 minutes, strong positive results may be observed promptly within 3 minutes ♦ Certified by Authoritative Certification System and Standards ♦ Winner of "the National Rapid Diagnostic Kit for Clinical Performance Assessment"
Intended Use
Principle
During the test, specimen is allowed to react with the colloidal gold particles, which have been labeled with Syphilis specific antigens. Antibodies to Syphilis, if present, a red colored band will develop on the membrane in proportion to the amount of Syphilis antibodies present in the specimen.
Absence of this red colored band in the test region suggests a negative result. To serve as a procedural control, a red colored band in the control region will always appear regardless the presence of antibodies to Syphilis. The RDT is simple, rapid, sensitive and specific.
Direction of Use
Interpretation of Results:
Negative: No apparent band in the test region (T), Only one red band appears in the control region (C). This indicates that no TP antibodies have been detected.
Note:
1. Must use fresh specimen and avoid repetitive freezing, the result will be invalid
2. Use it before expiry date.
3. The package of kit should not be opened until it reaches the room temperature if it taken out from the refrigerator.
4. Old Serum can not be used. If the serum is thick, it can be used only after being separated.
Storage
Reagents and Materials Provided
♦ One sealed pouched cassette with desiccant & a disposable pipe. ♦ Blood diluent in a dropper bottle. ♦ One piece of operating instruction with 40 test pouches.
Warning and Precautions
♦ FOR IN VITRO DIAGNOSTIC USES ONLY. ♦ All patient samples should be treated as if capable of transmitting diseases. ♦ Do not interchange reagents from different lots or use test kit beyond expiration date. ♦ Icteric, lipemic, hemolysed, heat treated and contaminated sera may cause erroneous results.
|
Product Tags: TP Syphilis Qualitative Detection Cassette 100% TP Syphilis Qualitative Detection Cassette 100% TP Syphilis Rapid Test Kit |