Mineral Oil Immersion Aluminum Fin Dry Fluid Cooler Chiller

Brand Name Shenglin
Model Number H*VS Series
Certification CE certification
Place of Origin China
Minimum Order Quantity 1
Price 505~31005 USD/Unit
Payment Terms T/T, Western Union
Supply Ability 50~100 units per month
Delivery Time 35~40days
Packaging Details For sample and less than container order: plywood case For Container order: pallet and wrapping film
Tube material Inner grooved copper tube
Fin material Hydrophilic aluminum fin or epoxy resin aluminum fin
Frame material Galvanized steel plate or stainless steel or aluminum
Fan brand High efficient axial, external rotor motor, Ziehl Abegg or equivalent fans
Application in HVAC 1 For data center air conditioning
Application in HVAC 2 Match with water cooled chiller
Application in HVAC 3 Immersion cooling system
Coil structure Floated type
Design capacity We can design and taior made for you with your specification.
Medium in tube Glycol/water
Detailed Product Description

Mineral Oil Immersion Cooling Copper Tube Aluminum Fin Air Dry Coolers

 

Why immerse?

 

  1. Silent Operations - Whether it’s single or two-phase immersion cooling, liquid cooling keeps your hardware submerged in a dielectric fluid of some type. More importantly, that will eliminates the noisy fans, which should be running throughout day and night in condition of air-based cooling and consume roughly 25-30% in additional power required to keep compute equipment on-line.
  2. Reduced PUE - Power usage effectiveness (PUE) is the ratio of a data center’s total facility energy to its total IT equipment (ITE) energy.Legacy or underside air-cooled techniques can struggle to maintain in the 1.8 to 2.4 range. Modern, purpose-built data centers have achieved significant PUE reductions using air-cooled chillers with closed-loop systems, often hitting a PUE of 1.3-1.5.With immersion cooling, PUE consistently stays under 1.3, drastically reducing a facility’s energy load.
  3. Cost Savings - Cooling accounts for a large part of operating expenses. A facility that houses thousands of servers is also expected to run 24/7, 365 days a year. In traditional air cooling, a large number of fans, HVAC and CRAC systems contribute a lot to the electricity bill. However, when servers are submerged in thermally conductive cooling solutions, electricity usage is reduced by more than 95%, which no one can refuse.

Application:

  • Data center air conditioning system.
  • Cryptocurrency cooling system.

 

Air dry cooler features:

Air discharge direction
Performance ranges

Cooling capacity: from 5 to 649 kw

Air volume: from 2828 to 263503 m3/h

Sound pressure level: from 31 to 69 dB A(10m)

Dry coolers:customized on demand

High efficiency heat exchanger

Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan.

Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition).

Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany

Fan

Only choose low specific energy consumption fans.

Fan nozzle designs for maximum air flow and air throw.

Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting.

Motor: protection class IP 54 and insulation class F.

Voltage:400V/3N/50Hz

Air separator for each fan.

TestingHeat exchangers are supplied clean and tested at a pressure of 30 bars
Options

Coil design refrigerant: water, oil, glycol.

Multiple circuits.

Sub-cooling circuits.

Stainless steel or aluminum casing.

Coated aluminum or copper fins.

Explosion ploof motor.

Customized fin spacing.


Dry fluid cooler technical parameter

FLAT SERIES SINGLE ROW FANS

H*VS*91
H*VS*125
Van Dim
mm
*H*VS191 H*VS1125H*VS291 H*VS212H*VS391 H*VS3125H*VS491 H*VS4125H*VS591 H*VS5125H*VS691 H*VS6125H*VS791 H*VS7125H*VS891 H*VS8125H*VS991 H*VS9125H*VS1091 H*VS10125
Rated Capacities (kW) Heat Exchange Surface (㎡)
Fluid Coolers910D69kW-1050kW 171㎡-4711㎡ (Water/Ta25℃/Tin40℃/Tout35℃)
1250182kW-2056kW 481㎡-8546㎡ (Water/Ta25℃/Tin40℃/Tout35℃)
Freon Condensers910F86kW-1167kW 171㎡-4711㎡ (R404A/Ta35℃/Tk50℃)
1250212kW-2340kW 481㎡-8546㎡ (R404A/Ta35℃/Tk50℃)
Ammonia Condensers910A93kW-1234kW 203㎡-6027㎡ (NH3/Ta35℃/Tk50℃)
1250201kW-2377kW 502㎡-10046㎡ (NH3/Ta35℃/Tk50℃)
Gas Coolers910G81kW-1534kW 259㎡-4711㎡ (CO2/Tair32℃/Tin113℃/P94Bar/Tout34℃)
Oil Coolers910O65kW-2126kW 171㎡-4711㎡ (OIL ISO VG 46/Ta35℃/Tin85℃/Tout60℃)
1250176kW-3548kW 481㎡-8546㎡ (OIL ISO VG 46/Ta35℃/Tin85℃/Tout60℃)
Fan Model910ECW3G910KU2503 (2.55kW) or FN091-ZIQ.GL.V5P1 (3.2kW)
910ACW6D910GB0101 (2.02kW) or FN091-SDS.6N.V7P2 (1.85kW)
1250EC160M2-8P-5.5kW/720RPM/1250_5-5_LP_39°_PPG_9W2L
1250AC160M2-8P-5.5kW/720RPM/1250_5-5_LP_39°_PPG_9W2L
No of Fans12345678910
Overall Dimensions910Lenth153027303930513063307530873099301113012330
Width2000
Width+Pad2260
Height2260
1250Lenth19303530513067308330993011530131301473016330
Width2000
Width+Pad2260
Height2360

 

Packing:

 

Product Tags: Aluminum Fin dry fluid cooler   Immersion dry fluid cooler   Aluminum Fin dry cooler chiller  