Wet-Dry Coolers Direct Water Spray Two Phase Liquid Bitcoin Cooling System
|
Wet-Dry Coolers With Direct Water Spray System For Bitcoin Two-phase Liquid Cooling System
Two-phase liquid cooling: The cooling liquid undergoes a phase change in the process of circulating heat dissipation. The cooling liquid takes away the heat from the server and then undergoes a phase change gasification. The gaseous cooling liquid is condensed by the condenser and becomes liquid again and returns to the liquid cooling tank; the cooling liquid can use 3M electronics The boiling point of the coolant FC-72 and FC-72 is above 50℃. In this case, the temperature of the water in the condensing coil does not need to be too low. The use of a dry cooler can meet the heat exchange requirements and take away the heat. The two-phase liquid cooling has a high heat transfer efficiency due to the phase change of the electronic cooling liquid. The disadvantage is that during this phase change, the electronic fluorinated liquid will escape during the vaporization process, so there is a certain degree of tightness of the container. However, it should not be too sealed to prevent the cooling system from being interrupted and the cylinder explosion event, so certain safety facilities need to be set up.
Features 1. High efficiency heat exchanger: capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. 2. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition). 3. Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany. 4. Fan: only choose low specific energy consumption fans. 5. Fan nozzle designs for maximum air flow and air throw. 6. Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting. 7. Motor: protection class IP 54 and insulation class F. 8. Air separator for each fan. 9. We facilitate you to have a long lasting and low maintainance operation. 10. Durable material and rigid enclosure with hard gloss powder coated finish. 11. Protective enclosure for both manifolds and U-bends. 12. Unit design for outdoor installation. 100% leakage tested at 31bar.
Options B. Multiple circuits. C. Sub-cooling circuits. D. Stainless steel or aluminum casing. E. Coated aluminum or copper fins. F. Explosion proof motor. G. Customized fin spacing.
Technical parameter Dry cooler D3 series parameter (fin space 2.1mm)
We can OEM design dry coolers. Tell us the datas as following:
Packing:
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: Liquid Bitcoin Cooling System Two phase Bitcoin Cooling System Two phase Bitcoin mining cooler |
![]() |
Two Phase Liquid Cooling Immersion Cryptocurrency Cooler |
![]() |
Adiabatic Dry BTC Bitcoin Cooling System Anti Corrosion |
![]() |
Gold Fin Adiabatic Dry Cooler Crypto BTC Cooling System |
![]() |
Flat Type High Heat Transfer Efficiency Immersion Bitcoin Cooling System |
![]() |
Submerging Bitcoin Miners Two Phase Immersion Cooling Dry Coolers |
![]() |
Wet-Dry Coolers Direct Water Spray Two Phase Liquid Bitcoin Cooling System |