Non Standard Purification Vertical AHU Clean Room Air Handling Units
|
Non-standard Customization Purification Air Conditioning Unit For PCR DetectionFeature: integral design, simple and convenient installation and operation, inverter compressor, dual EC fan, PLC high precision constant temperature and humidity control. Non-standard design. Clean operating room air conditioning system solution Ⅰl DC frequency conversion outdoor unit + clean operating room air conditioning unit + PLC intelligent control
1,Frequency conversion technology: The DC frequency conversion compressor is used to adjust the operating frequency of the compressor according to the temperature change, which is efficient and energy-saving 2,Low ambient temperature cooling: The outdoor unit adopts EC fan, and the speed of the outdoor fan is controlled by the condensing pressure sensor to achieve -20℃ low temperature cooling operation; 3,Low temperature air supply: Shenglin's unique technology, through the grading and separate control of the evaporator, reduces the evaporation temperature, and the minimum air supply temperature is 5℃; 4,Precise temperature control: electric reheating and electric preheating are steplessly adjusted by SCR to accurately control the indoor temperature 5,Low ring temperature heating: advanced air jet enthalpy technology, normal heating operation at an ambient temperature of -20°C.
Air conditioning system solution for clean operating room Ⅱl Four-pipe air-cooled heat pump heat recovery unit + clean operating room combined air conditioner + PLC controlMulti-function: four-pipe, frequency conversion adjustment, cooling and heating operation can realize energy recovery at the same time, no need to add a hot water tank to adjust the water capacity on the hot water side; Low-temperature heating: Adopting jet enthalpy and high-temperature liquid injection technology, heating operation at minus 20℃, and energy efficiency ratio higher than 2.1; Low temperature refrigeration: EC fan is used to detect the discharge pressure of the compressor to achieve normal refrigeration at -20°C, Cooling and heating balance: automatic cooling and heating balance under partial cooling and heating load, automatic distribution of refrigerant flow; System stability: Adopting single four-valve design, consistent operation, mature system technology, stable and reliable operation; Energy saving and environmental protection: annual heat recovery can be realized, energy recovery can be adjusted, cooling energy efficiency ratio ≥ 4.0, while heat energy efficiency ratio ≥ 5.0, combined cooling and heating energy efficiency ratio ≥ 9.0, operation energy saving effect is more significant ; Intelligent control: Microcomputer PLC control technology, automatically detects the operating status, and realizes energy-saving operation; Fault self-check: automatic fault detection system can detect operation faults such as suction and exhaust pressure, exhaust temperature, phase loss and reverse phase, overcurrent and overload; Unique technology: the perfect combination of single four-way valve design, ultra-low temperature heating design, low temperature refrigeration design, and stable mode conversion.
Clean operating room air conditioning system solution Ⅲl Air-cooled heat pump + clean operating room combined air conditioning unit + PLC controlPrecise temperature control: DC inverter compressor is used, and the operating power of the compressor is self-matched according to changes in ambient temperature;Low ambient temperature refrigeration: The outdoor unit adopts EC fan, and the speed of the outdoor fan is controlled by the condensing pressure sensor to achieve -20℃ low temperature cooling operation;Low ring temperature heating: advanced air jet enthalpy technology, normal heating operation at an ambient temperature of -20℃;Intelligent defrosting: super-cooling ice suppression technology, combined with Sunlin’s unique defrosting module, with frost defrosting, frost-free heatingSmart cloud service: PC client + mobile App real-time monitoring.Standard AHU model representation method:
Unit quick selection table (air volume)
Note: 1. It is recommended to add a water baffle if the wind speed exceeds 2.75m/s.
Unit quick selection table (cooling capacity of coil section under return air condition)
Note: 1. The inlet temperature of chilled water is 7°C, and the outlet temperature is 12°C; 2. Return air condition: inlet air dry bulb temperature 27℃, wet bulb temperature 19.5℃; 3. The above parameters are for reference only. If the working conditions and coil circuit arrangement are changed, the parameters will change. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: Purification Clean Room Air Handling Units Non standard ahu air conditioning system Purification ahu air conditioning system |
![]() |
SurgicaL 5000M3/H Ahu Indoor Units Clean Room Air Handling Units |
![]() |
Combined Heating &Cooling System Chilled Water Floor Mounted Air Handling Unit |
![]() |
Constant Temperature Humidity Clean Room Air Handling Units For Hospital |
![]() |
GMP Cleanroom Constant Temperature Humidity Air Treatment Unit |
![]() |
Central HVAC System SL Series Chilled Water Air Handlers |
![]() |
Direct Expansion Floor Standing Air Handling Units AC Air Handlers |