GMP Cleanroom Constant Temperature Humidity Air Treatment Unit
|
Clean Room Constant Temperature And Humidity Air Handling Units
Product series which we can do:
1. Constant temperature and humidity type unit
Feature:
1. Filter: G4+F7+F11+FFU(end user side).
2. 10~30% fresh air.
3. Inveter compressor.
4. EC fans.
5. Analog control valve.
6. Dry coils
7. Meet GMP requirements
8. Purification engineering: including electronic information, semiconductors, optoelectronics, precision manufacturing, medicine and health, biological engineering, aerospace, automotive spraying and many other industries
Advantage of direct expansion air handling units:
No water system, no secondary heat exchange, no large computer room and control, simple installation and construction
The difference with other air conditioning units:
1. Good sealing, heat preservation and pressure bearing performance
(low air leakage rate, low deformation rate, no cold bridge);
Parts and material:
1. Frame and panel: A. Adopt double-sided incubator panels, all outer panels are made
of color galvanized steel, and the inner panel can be equipped with
color galvanized steel or stainless steel according to user needs;
2. Heat Exchanger: A. The standard configuration is copper tube with aluminum fin with anticorrosive hydrophilic coating B. The collection tube is all made of red copper tube, and the welding quality of the same material is guaranteed; C. The expansion tube adopts a mechanical low-speed pulsation process, which has high heat transfer efficiency; D. Pipe pressure test and leak detection one by one, the maximum working pressure can reach 25bar; E. Equipped with stainless steel dry condensate pan; F. If necessary, the machine can be equipped with antifreeze protection device for coil maintenance during shutdown
3. Electric heating: A. Adopt thermal ceramic electric heating element; no short circuit problem, which helps to eliminate fire hazards; B. No electricity on the surface, no electric shock hazard; C. Heating element has no oxidation problem and has a long service life; D. Each PTC is equipped with a high temperature protection switch; E. Can offer duct type PTC electric heating box
4. Electrode humidifier: A. Adopt Swiss condair electrode humidifier; B. Integrated structure, beautiful appearance, more convenient for maintenance outside the cabinet; C. Replaceable or washable humidification barrel, maintenance-free electrode; D. Equipped with stainless steel humidification nozzle and connecting hose; E. Equipped with water quality adjustment It can adapt to the humidification needs under various water quality conditions; F. It can be controlled by the unit controller to achieve continuous control of the humidification amount; G. Or it can be equipped with a humidification controller for independent humidity control; H. Other brand products can be optional
|
Product Tags: GMP air treatment unit Cleanroom air treatment unit Cleanroom ac handler unit |
![]() |
SurgicaL 5000M3/H Ahu Indoor Units Clean Room Air Handling Units |
![]() |
Combined Heating &Cooling System Chilled Water Floor Mounted Air Handling Unit |
![]() |
Constant Temperature Humidity Clean Room Air Handling Units For Hospital |
![]() |
GMP Cleanroom Constant Temperature Humidity Air Treatment Unit |
![]() |
Central HVAC System SL Series Chilled Water Air Handlers |
![]() |
Direct Expansion Floor Standing Air Handling Units AC Air Handlers |