Newborn Heel Stick Lancets with Motion Micro Surgical Blade Design
|
Newborn Heel Stick Lancets with Motion Micro Surgical Blade Design 【Heel Stick Lancets Information】
【Heel Stick Lancets Safety Mechanism】 【Heel Stick Lancets Information】
【Heel Stick Lancets Specifications】 【Heel Stick Lancets Features】 Motion blade incision causes less trauma than “Puncture” type lancet device; Newborn heel incision device is available in different depths/widths of cut for individual needs; Heel lancet is single-use only, auto-disabling to prevent unwanted sharps injuries; Arrow on bottom helps accurately align target area; Patented ergonomic anti-slip grip helps reduce chance of unwanted bruising; Heel stick lancing device is sterile, individually packaged, non-porous material. 【Heel Stick Lancets Advantages】 Studies have shown that the need for repeat sticks when using a micro-blade newborn lancet is virtually eliminated, also a reduction in pain reponse from the infant test subjects. Post testing showed that the incision site is often well healed within 24 hours with minimal signs of prolonged superficial bruising or hematoma. Additionally, the blood samples obtained by the micro-blade infant lancet imporoved testing accuracy and enabled the blood to flow more naturally without the need to press or massage. 【Heel Stick Lancets Cautions】 1. Read the instructions carefully before use; 2. Using the heel lancet within the expiry date; 3. Do not use if primary package is broken; 4. For your safety, never use a heel lancet device that has been
used by someone else. Single use Safety lancets are not intended
for use on multiple individuals. 5. In the event of any serious adverse event, the manufacturer
shall issue an advisory notice and take action in accordance with
the manufacturer's procedures. 【Heel Stick Lancets Use Instructions】 Step 1: Select the optimal lancing site. Clean the site with an antiseptic swab and allow to air dry; Step 2: Open the blister package and take out the safety lancet. Step 3: Place the lancing device against the baby’s heel and activate by pressing downward on the button.Then collect the blood sample. Step 4: Discard the used lancet device into an appropriate container. 【Heel Stick Lancets Storage】 The newborn heel incision device should be stored in a well-ventilated room away from light and moisture, free from corrosive gases. |
![]() |
Newborn Heel Stick Lancets with Motion Micro Surgical Blade Design |
![]() |
Qbutton Heel Incision Device for Newborn Screening Test |
![]() |
Ultra Sharp Safety Lancet Needle 21G with Puncture Depth 2.2mm |
![]() |
Individually Packed Safety-engineered Heel Blade Infant Safety Lancet |
![]() |
Innovative Quality Button Activated Safety Blood Lancet 26G 28G Depth 1.8mm |
![]() |
Micro Sweeping Blade Heel Stick Safety Lancet 0.85mm*1.75mm, Purple |