Product Introduction
This complete printhead assembly, including the connecting cables, is a key output module of the electrocardiograph (ECG) machine. It is responsible for real-time thermal printing of ECG waveforms, numerical data, and diagnostic reports, directly determining the clarity and completeness of printed medical records.
After prolonged high-frequency clinical printing, the printhead core is prone to wear, carbon buildup, and aging. Common malfunctions during daily use include blurry prints, missing lines, uneven color density, and even complete printing failure. This original factory-installed printhead assembly features integrated wiring and a one-piece structure for easy replacement.
Specifications
Advantages
1. The print head has a resolution of 8 dots/mm. This allows it to accurately reproduce even the smallest ECG waveform details, such as T-wave changes and arrhythmias, with a waveform positional error of less than 0.05mm. This clarity is essential for a confident diagnosis.
2. The printing surface has a high-hardness ceramic coating (HRC62) that protects it from wear caused by the paper. With a lifespan of over 400,000 prints, a busy clinic running 30 ECGs per day can expect this part to run reliably for 2‑3 years.
3. Built-In Safety Systems, It includes overheat protection (which shuts down the heater if it goes above 60°C) and an 8kV electrostatic discharge (ESD) protection circuit. It also meets the IPX1 water ingress protection standard
Disassembly StepsPower off the ECG machine completely and disconnect the external
power supply before disassembly to prevent circuit burnout caused
by live operation. Open the printer compartment cover and remove
the internal thermal paper roll to fully expose the printhead
fixing position and cable interface. Loosen the fixed buckles and screws of the original printhead, hold
the cable connector root steadily, and pull out the wire harness
gently. Do not pull the cable body forcibly to avoid breaking the
internal wire core or damaging the interface pins. Take out the old
printhead assembly and clean dust and carbon deposits inside the
printing cabin. |
| Product Tags: ECG machine printhead replacement Carewell ECG-1112 printhead with cable Patient monitor ECG printhead SHEC C216 |
|
Mindray Patient Monitor Battery LI13I001A Suit For Ipm5 Ipm8 Ipm10 Ipm12 IMEC5 IMEC8 IMEC10 IMEC12 New |
|
051-000943-00 Patient Monitor Spo2 Board Mindray T1 IPM12 IPM10 IPM8 Imec8 Imec10 Imec12 |
|
Patient Monitor Printer Recorder TR60-F Mindray IMEC7 IMEC8 IMEC10 IMEC12 IPM8 IPM9 IPM10 IPM12 MEC T5 T6 T8 Series |
|
PHiliph MX400 MX450 MX Series Patient Monitor AC/DC IV2-FLEX ASSY-PWR AC / DC Power Supply 453564281221 |
|
P/N 453564271711 PHiliph MX400 Mx450 MX Series Patient Monitor Mainboard |
|
MX450 Patient Monitor Battery Board Power Supply Hospital Equipment |