Nihon Kohden BSM-4113K Patient Monitor Battery Compartment With Battery Interface Wiring
|
|
Nihon Kohden BSM-4113K Patient Monitor Battery Compartment With Battery Interface Wiring This is the original accessory for the BSM-4113K patient monitor—the battery compartment, which includes a battery interface cable. This battery compartment serves as the mounting base for the BSM-4113K monitor's internal battery and provides the power supply interface. It works with the battery interface cable to connect to the monitor and supply power. The battery compartment features a white rectangular recessed design made of medical-grade engineering plastic, providing stable mechanical support for the device's internal battery. Inside the compartment are positive and negative metal contacts for the battery terminals, allowing for electrical contact and enabling the device to be powered and the battery to be charged. Functions and Advantages 1. Battery Installation and Support: The battery compartment provides precise positioning and stable support for the battery, ensuring its stability during device movement and preventing poor contact or detachment. 2. Power Transmission: The battery compartment's built-in cable transmits power from the battery to the device's mainboard for normal operation; it also allows for battery charging when the device is connected to AC power. 3. Battery Level Detection and Management: The battery compartment's signal cable connects to the mainboard, providing feedback on battery status, such as remaining power and charging status, ensuring accurate battery level display and triggering low-battery alarms. 4. Electrical Safety and Connection Protection: A red/black/white three-wire design avoids reverse connection risks; the enclosed compartment design prevents battery contacts from moisture, oxidation, or dust contamination, ensuring stable grounding and power supply. Technical Specifications
Product Images FAQ Q1: The device display shows "Unable to recognize battery," is it a battery compartment malfunction? A1: A battery compartment malfunction is highly likely. First, install the battery in another working device to see if it functions normally. If it does, the battery is not the problem. Then check if the metal contacts inside the battery compartment are normal, checking for oxidation, deformation, etc.; check if the connecting cable is broken or the interface is loose. If the contacts and cable are normal, the internal detection circuit of the compartment may be damaged. Q2: After installing the battery, the device can be turned on but shuts down as soon as the power is unplugged. Is the battery compartment faulty? A2: Most likely. It may be due to poor contact of the power supply contacts inside the compartment, preventing the battery from supplying power, or a broken battery interface cable. Professional equipment is needed to check the connection between the cable and the contacts. Q3: The contacts in the battery compartment are yellowed, how do I fix it? A3: You can clean them with anhydrous alcohol and dry them; if the contacts are deformed, the entire battery compartment must be replaced to avoid excessive contact resistance that could damage the device. Ordering Information
|
||||||||||||||||||||||
| Product Tags: Nihon Kohden BSM-4113K battery compartment patient monitor battery interface wiring Nihon Kohden monitor battery replacement part |
|
Mindray Patient Monitor Battery LI13I001A Suit For Ipm5 Ipm8 Ipm10 Ipm12 IMEC5 IMEC8 IMEC10 IMEC12 New |
|
051-000943-00 Patient Monitor Spo2 Board Mindray T1 IPM12 IPM10 IPM8 Imec8 Imec10 Imec12 |
|
Patient Monitor Printer Recorder TR60-F Mindray IMEC7 IMEC8 IMEC10 IMEC12 IPM8 IPM9 IPM10 IPM12 MEC T5 T6 T8 Series |
|
PHiliph MX400 MX450 MX Series Patient Monitor AC/DC IV2-FLEX ASSY-PWR AC / DC Power Supply 453564281221 |
|
P/N 453564271711 PHiliph MX400 Mx450 MX Series Patient Monitor Mainboard |
|
MX450 Patient Monitor Battery Board Power Supply Hospital Equipment |