Biolight BLT M66 Patient Monitor Temperature Interface with Connection Cable
|
|
Temp Interface for BLT M66 Biolight BLT M66 Patient Monitor Temperature Interface with Connection Cable ► Brief Description The Biolight M66 Patient Monitor is a high-performance professional medical device widely used in operating rooms, ICUs, and emergency departments. It monitors various physiological parameters of patients, including heart rate, blood pressure, blood oxygen saturation, respiration, and body temperature. These parameters are monitored through the monitor's interface, with the temperature sensor interface particularly well-designed, combining high precision with high compatibility. ► Detailed Photos ► Advantages The Biolight M66 Patient Monitor features a dual-temperature interface, measuring from 0°C to 50°C (covering human body temperature and extracorporeal circulation temperature). It is compatible with both thermistor and thermocouple probes: 1. Thermistor: It operates based on the characteristic that the resistance of a semiconductor changes with temperature. The M66's interface circuitry is designed to accurately measure minute resistance changes and convert them into temperature readings. 2. Thermocouple: Some configurations support thermocouples, which operate based on the Seebeck effect and are suitable for scenarios requiring extremely fast response times, such as deep esophageal or rectal temperature measurement. ► T1/T2 Design The Biolight M66's temperature sensor interface supports multiple probe connections to meet diverse clinical needs:
► Working Principle The Biolight M66 is more than just a display device; its integrated signal processing unit performs complex processing on the raw data received from the sensor interface: - Analog-to-Digital Conversion (ADC): The analog electrical signal received by the interface is converted into a digital signal using a high-precision ADC. - Linearization Correction: Since the resistance of a thermistor typically has a non-linear relationship with temperature, the M66's internal algorithm linearizes the signal, ensuring that the value displayed on the screen is an accurate linear temperature value. - Anti-interference Design: In operating room environments, devices such as electrosurgical units generate high-frequency interference. The M66's temperature interface has a filtering function that effectively filters out environmental noise and prevents abnormal fluctuations in body temperature readings. |
| Product Tags: Biolight BLT M66 patient monitor patient monitor temperature interface patient monitor connection cable |
|
Mindray Patient Monitor Battery LI13I001A Suit For Ipm5 Ipm8 Ipm10 Ipm12 IMEC5 IMEC8 IMEC10 IMEC12 New |
|
051-000943-00 Patient Monitor Spo2 Board Mindray T1 IPM12 IPM10 IPM8 Imec8 Imec10 Imec12 |
|
Patient Monitor Printer Recorder TR60-F Mindray IMEC7 IMEC8 IMEC10 IMEC12 IPM8 IPM9 IPM10 IPM12 MEC T5 T6 T8 Series |
|
PHiliph MX400 MX450 MX Series Patient Monitor AC/DC IV2-FLEX ASSY-PWR AC / DC Power Supply 453564281221 |
|
P/N 453564271711 PHiliph MX400 Mx450 MX Series Patient Monitor Mainboard |
|
MX450 Patient Monitor Battery Board Power Supply Hospital Equipment |