Comen C60 Patient Monitor Pulse Oximeter Board MS-2040 36292

Brand Name Comen
Model Number C60
Minimum Order Quantity 1
Payment Terms T/T, Western Union,Paypal
Delivery Time 3-5 working days
Product Name Pulse Oximetry Board
PN MS-2040 36292
Material PCB, Electronic Components
Machine Application C60 Series Patient Monitor
Function Noninvasive SpO₂ and Pulse Rate Signal Processing
Power < 45 mW
Technology SET
Measurement 100%
Patient Types Neonatal, Pediatric, Adult
Warranty 90 Days
Detailed Product Description

Comen C60 Patient Monitor Pulse Oximeter Board MS-2040 36292

 

Product Introduction

 

This product is the  MS-2040 pulse oximetry monitoring board (model: 36292), used in the C60 patient monitor. This board features a compact, high-density PCB design and utilizes  signal extraction technology. It directly connects to the host's pulse oximetry signal port, relying on mature optical acquisition algorithms to accurately receive, analyze, and transmit pulse oximetry and pulse rate signals. Precise pulse oximetry values ​​and pulse waveforms are stably transmitted to the host screen for display and archiving. Simultaneously, status signals such as abnormal connection drops, probe detachment, and low signal levels are also synchronously fed back to the host, triggering standard audible and visual alerts to ensure accurate and timely clinical monitoring.

 

 

Comen SPO2

 

  • Resolution:1%
  • Measurement & alarm rangel~100%
  • Accuracy:   +2% (70~100%,Ped, non-motion+
  •                    +3% (70-100%, Neo, non-motion);
  •                    0-69% unspecified
  • Alarm range: 0~100%
  • Pulse rate: Range: 20~250bpm
  • Resolution: 1bpm
  • Accuracy:+3bpm(non-motion)
  •                 +5bpm(motion)
  • Alarm range: 20~250bpm

Advantages

 

1. Integrating original core signal processing algorithm, coupled with multi-level filtering circuits and anti-static and anti-electromagnetic interference designs, it effectively resists interference from electrosurgical units and high-frequency equipment in wards. Even in scenarios with weak perfusion or high patient limb movement, it maintains stable blood oxygen and pulse rate data, avoiding numerical jumps and no readings.

 

2.Utilizing industrial-grade medical components, the FR-4 flame-retardant PCB substrate is high-temperature resistant and anti-aging, capable of withstanding 24 hours of continuous full-load operation. Long-term use is less prone to component bulging, circuit burning, and board damage, making it suitable for the high-frequency monitoring needs of hospitals.

 

3.Independent PCB board structure eliminates the need to disassemble the core components of the entire unit. In case of failure, individual boards can be disassembled and replaced, significantly reducing equipment downtime, lowering maintenance costs, and ensuring uninterrupted clinical monitoring.

 

Disassembly Procedure

 

Before proceeding, ensure all necessary preparations are complete: Turn off the Comen C60 monitor, disconnect the power cord and all external pulse oximeter probes and leads.

 

1. Unscrew the screws securing the monitor to the back or side of the unit. Gently remove the back cover/side cover to expose the internal circuit board installation area.

 

2. Locate the ribbon cable connector on the circuit board. Pinch the elastic clips at both ends of the ribbon cable and gently pull it outwards (do not pull the cable directly to prevent pin breakage or wire damage).

 

3. Unscrew the screws securing the pulse oximeter plate at the four corners. Store the screws carefully to avoid loss. Gently lift the circuit board by holding both sides with both hands to remove the old pulse oximeter plate completely.

Product Tags: Comen C60 patient monitor oximeter board   Massimo pulse oximeter replacement part   MS-2040 patient monitor repair component  